Summary of Contents for Orisec PZX-10

  • Page 1 PZX-10 Installation Manual Designed and Manufactured in the United Kingdom www.orisec.co.uk...
  • Page 2: Table Of Contents

    Power Supply (SMPS). The PZX-10 is available in either a polymer enclosure which has space for a 7Ah battery or a metal enclosure Mounting ..................2 which has space for a 17Ah battery. Features of the Orisec PZX-10 Polymer Enclosure ................ 2 include: Metal Enclosure ................
  • Page 3: Metal Enclosure

    PSU location Battery space (up to 7Ah) Tamper switch WebWayOne Nano fixing (See below) CSL Digi air fixing Removable cable entry shutters Remove pillar to fit WebWayOne Nano Metal Enclosure Removing the metal control panel lid PSU location Battery space (up to 17Ah) Tamper switch PCB gantry –...
  • Page 4: Wiring The Pzx-10 Expander

    Wiring the PZX-10 Expander WARNING: ELECTRICITY CAN KILL Before connecting the PZX-10 Expander always disconnect the power supply at the consumer unit. Seek advice from a qualified electrician if in any doubt. Only connect the mains supply to the switch mode power supply.
  • Page 5: Pcb Layout

    8. Address Selection installation manual. Each PZX-10 must be assigned a different address using the Address 3. Outputs 1-10 selector. Set the DIP switch to the required position: These are fully programmable, switched negative outputs. Each...
  • Page 6: Connecting Devices To The Network

    9. Select button The local select button will allow for local programming and The maximum recommended distance for devices when using addressing of the PZX-10 through the on-board 7-segment display, standard 7/0.2 alarm cable is: see page 9 for full details.
  • Page 7: Network Wiring Examples

    Network wiring examples Zone Expander – with standard alarm cable Zone Expanders and keypads – with standard alarm cable Using RJ-45 patch lead to connect devices...
  • Page 8: Wiring Detection Devices

    Wiring Detection Devices Outputs Each zone can be wired using different wiring methods. The figure The outputs can be used to control auxiliary devices e.g., sounders, below shows the ‘Double EOL’ wiring method, for full details on LEDs, Relays etc. The figures below show some wiring examples: available wiring methods, please refer to the control panel LED Indicator installation manual.
  • Page 9: 7-Segment Display & Select Button

    7-Segment display & Select button The menus are as follows; Ad - Address The 7-segment display shows the PZX-10 network address when the This menu allows for the expanders address to be control panel is in engineer’s mode and scrolls through the outer set via software as opposed to hard addressed by segments when operating normally.
  • Page 10: Wireless Bridge

    Press and hold the “Learn” button on the W-XP-R for 1  second. NOTE: For tamper monitoring on the W-XP-R program the zone as ‘W- KP/Bell/TR’ Once configured the PZX-10 will be seen in “Confirmed Devices”. Please refer to the W-XP-R Installation Manual for additional information.
  • Page 11: Specifications & Standards

    Disclaimer: Orisec will not accept any liability based on a claim that Storage Temperature: -20°C to +60°C the Orisec PZX-10 failed to perform correctly as it is a component part of an installation and not a complete intruder alarm system. Max. Humidity:...
  • Page 12 UK Based Technical Support t: +44 (0) 1706 398740 e: support@orisec.co.uk © Orisec Ltd 2018 INS027...