General safety information General safety information • Reading the operating instructions before putting the device into operation is essential. Read the notes carefully. They contain important information on safety during commissioning, use and maintenance of the device. • Only the manufacturer or personnel who have been authorized by the manufacturer may open the device, unless otherwise explicitly stated in this manual.
Notice Notice • The operating instructions help to operate the device safely. Therefore, always retain the operating instructions for future use. Store the operating instructions by the device so that they are accessible to all users. • The product and manual are intended for trained cosmeticians. •...
Explanation of notes and symbols Explanation of notes and symbols Warnings This is a warning of immediate danger leading to death or severe injury. DANGER This is the text which describes the corrective action. • This is a warning of potential danger which can lead to death or severe injury. WARNING This is the text which describes the corrective action.
IONTO-Galvano IONTO-Galvano Contraindications In general, don't use the IONTO-GALVANO in case of the following indications: General contraindications Heart disease Pregnancy Cancer and tumors, and/or suspicion of (malignant) tumors Tetany (convulsive muscle spasms) Febrile diseases Embolisms Nervous system diseases Skin diseases such as rosacea, neurodermatitis and psoriasis (since episodes can generally be triggered by a stimulating treatment) General contraindicated treatment areas In inflamed areas, open wounds...
IONTO-Galvano Area of application The IONTO-GALVANO is an iontophoresis device. It is designed to efficiently administer active substances into deeper layers of the skin. The skin is also massaged through application of the GALVANETICS method. The GALVANETICS handpieces have an extremely high conductivity and are therefore essential for efficient administration.
IONTO-Galvano GALVANETICS INFO The GALVANETICS and connecting cable aren't included in the scope of deliv- ery, but have to be ordered as accessories. (10) GALVANETICS handpiece (11) GALVANETICS-CARBON-SILICON electrode (12) Optional handpiece holder Fig. 2: GALVANETICS Putting into operation Device Setting the device up The place where the IONTO-GALVANO is set up must meet certain requirements: To set the device up correctly:...
IONTO-Galvano GALVANETICS You require two GALVANETICS units to perform a treatment. These can be ordered separately as accessories. Connecting the GALVANETICS to the device Connect the GALVANETICS to the device as follows: Connect the transmission cable with the black jack to one of the GALVANETICS. Connect the transmission cable with the red jack to the other GALVANETICS.
IONTO-Galvano Treatment settings Setting the polarity After you have turned the device on, the polarity is set to negative (-) by default. If you are using the GALVANETICS Ultimate Youth Serum treatment product, exchange the two GALVANETICS handpieces as soon as half of the treatment time has passed. To change the polarity if you are working with other active ingredient compounds: Press the polarity button (2) to change the polarity.
IONTO-Galvano Setting the intensity before treatment Risk of heart injury. This results in heart function disorders. CAUTION Set the handpieces on the body so that the current doesn't have to flow • past/through the heart on its way from handpiece to handpiece. INFO The current which actually flows varies according to the position of the body and how the handpieces are moved.
IONTO-Galvano INFO The current level which the customer perceives can change during the treatment. The reason for this is that the skin consists of live tissue with blood circulation and variable water and fat content, which doesn't have a constant electrical conduc- tivity.
IONTO-Galvano Cleaning and care Danger due to electrical shocks. These can cause deadly injuries. WARNING Each time before cleaning the device, turn it off and pull the power plug. • Housing Cleaning NOTE Incorrect cleaning and care can result in damage to the device. This causes housing damage.
IONTO-Galvano Scope of delivery Number Item number Item name 8826.8120 IONTO-GALVANO Accessories Item number Item name 8826.1 Universal handpiece holder 8435.201 Spiral cable set, white 8242.3 GALVANETICS Set (2 x GALVANETICS, 1 x GALVANETICS treatment manual, 1 x GALVANETICS Ultimate Youth Serum) 8242.4 GALVANETICS Ultimate Youth Serum, 125 ml 9223.90...
IONTO-SKIN® Regulator ® IONTO-SKIN Regulator Contraindications In general, only treat healthy people. The contraindications apply both to the customer and to the cosmetician performing the treatment. ® Don't use the IONTO-SKIN Regulator at the following locations and in case of the following indica- tions: Heart disease Pacemaker...
IONTO-SKIN® Regulator Description Device housing and control panel Fig. 3: Device housing and control panel (1) Housing (2) Select face treatment (3) Select body treatment (4) Adjusting the frequency (5) Reduce the intensity (6) Increase the intensity (7) Turn the device on or off / (8) Slider with intensity indicator Start or stop treatment Additional scope of delivery...
Set the device up on a surface which is level, solid and heat resistant. Don't set the device on a towel or blanket. Ensure that the ventilation slots are free and not covered. If you own several IONTO-COMED ® Essential Line devices, you can stack up to 3 devices on top of one another.
IONTO-SKIN® Regulator Operation Device Turning the device on To turn the device on: Place the mains switch on the back of the device in position |. Then the device is in standby mode. Press and hold the On/Off button (7) for 2 seconds. Then the device is turned on and the keypad backlighting is active.
IONTO-SKIN® Regulator Adjusting the frequency How high you should set the frequency depends on the treatment you want to perform. The follow- ing table shows possible settings and corresponding applications: Frequency Effect 5 Hz Lymphatic massage 10 Hz Supporting lymphatic massage 20 Hz Stimulating blood flow, activating, stimulating, improved absorption of active ingredients, relaxation...
IONTO-SKIN® Regulator To prepare the customer's skin and yourself for the treatment: Clean the customer's skin with a non-moisturizing cleaning foam or gel. Dry the customer's skin. Clean your hands with a non-moisturizing soap product. Dry your hands. Use the provided powder if your hands or the customer's skin become moist again. Then the treatment area is cleaned and dried.
IONTO-SKIN® Regulator Starting treatment To start the treatment: Press the On/Off button (7). This starts the treatment. Ending the treatment To end the treatment: Press the On/Off button (7). The treatment stops. The settings are retained. Regular maintenance and inspection The device doesn't require any maintenance if it is used properly and as intended.
IONTO-SKIN® Regulator Electrodes NOTE Incorrect cleaning and care can result in damage to the electrodes. This causes electrode damage. Don't immerse the wand in liquid. • INFO If you are using disposable electrodes: Disposable adhesive electrodes are one time use electrodes. Never use them more than once. Caring for reusable adhesive electrodes To care for reusable adhesive electrodes: After use, stick the reusable adhesive electrodes to the plastic surface they came with.
IONTO-SKIN® Regulator Accessories Item number Item name Vinyl gloves, one package of 100 gloves 8228.050 Size S 8228.051 Size M 8228.052 Size L 8228.011 Sweatbands, 1 pair, one size fits all, white 8228.007 Holder for Sensomembrane. 8228.031 Sensomembrane, 1 roll, 30 x 30 cm 8228.009 Reusable adhesive electrodes, SKIN Regulator, 1 package of 4 8228.005...
IONTO-ICE & HEAT IONTO-ICE & HEAT Contraindications In general, only treat healthy people. Don't use the IONTO-ICE & HEAT on the following areas and in case of the following indications: Rosacea Facial erythrosis, after consulting a dermatologist Herpes Open wounds Inflamed skin In case of doubt you should consult with a physician.
IONTO-ICE & HEAT Description Device housing and control panel Fig. 5: Device housing and control panel (1) Housing (2) Activating the cooling function (3) Activating the warming function (4) Reduce the intensity (5) Slider with intensity indicator (6) Increase the intensity (7) Turn the device on or off / Start or stop treatment Handpiece...
Set the device up on a surface which is level, solid and heat resistant. Don't set the device on a towel or blanket. Ensure that the ventilation slots are free and not covered. If you own several IONTO-COMED ® Essential Line devices, you can stack up to 3 devices on top of one another.
IONTO-ICE & HEAT Operation Device Turning the device on INFO Turn the IONTO ICE & HEAT on 2 minutes before you plan to use it. To turn the device on: Place the mains switch on the back of the device in position |. Then the device is in standby mode.
Page 32
IONTO-ICE & HEAT Activating the cooling function To activate the cooling function: Ensure that the metal ring (10) has been removed from the handpiece. If the metal ring is installed on the handpiece, pull it off the tip of the handpiece. Press the cooling function button (2).
IONTO-ICE & HEAT Ending the treatment INFO Turn the device of when you have completed the treatment. To end the treatment: Press the On/Off button (7). The treatment stops. The settings are retained. Regular maintenance and inspection The device doesn't require any maintenance if it is used properly and as intended. Repairs may only be performed by authorized specialists from the manufacturer.
IONTO-ICE & HEAT Cleaning and disinfecting the handpiece Clean and disinfect the handpiece after every use. To clean and disinfect the handpiece: Remove product residue. Disinfect the handpiece with a disinfectant wipe. INFO We recommend the wipe disinfectant Bacillol Tissues (item no. 9220.502). Then the handpiece is cleaned.
IONTO-PEEL IONTO-PEEL Contraindications In general, only treat healthy people. Don't use the IONTO-Peel on the following areas and in case of the following indications: Inflamed areas of skin Herpes Simplex In case of doubt you should consult with a physician. Area of application The IONTO-Peel offers speeds of 20 to 600 RPM.
Set the device up on a surface which is level, solid and heat resistant. Don't set the device on a towel or blanket. Ensure that the ventilation slots are free and not covered. If you own several IONTO-COMED ® Essential Line devices, you can stack up to 3 devices on top of one another.
The Peel handpiece is now connected to the device. Fitting attachments to the Peel handpiece Attachments include brushes, pumice stones or sponge holders. Only IONTO-COMED attachments fit the thread of the Peel handpiece. Ensure that the handpiece isn't turned on. Hold the attachment holder (9) securely.
IONTO-PEEL Placing the device in standby mode or turning it off You can turn the device off completely or place it in standby mode. If the device is in standby mode, it is ready to use more quickly when you want to turn it back on. To place the device in standby mode or turn it off: To place the device in standby mode, press and hold the On/Off button (7) for 2 seconds.
IONTO-PEEL Memory function Saving the speed setting To save the current rotational speed setting: Use the (+) and (-) buttons ((6) or (4)) or the slider (5) to set the rota- tional speed you want to save. Press and hold the memory button (3) for 3 seconds. The signal only turns off after you release the memory button.
IONTO-PEEL Housing Cleaning NOTE Incorrect cleaning and care can result in damage to the device. This causes housing damage. Don’t use any aggressive or abrasive cleaning agents. • To clean the device housing: Clean the device regularly with an aldehyde-based disinfectant. ...
IONTO-PEEL Cleaning To clean brushes, pumice stones, sponge holders and sponges: Remove product residue under running water. Place the parts in a disinfection pan or an ultrasonic bath. Alternately, disinfect the parts via spray disinfection. Then wash the parts with a disinfectant soap. Dry the parts.
IONTO-HF IONTO-HF Contraindications In general, only treat healthy people. Don't use the IONTO-HF on the following areas and in case of the following indications: Heart disease Pacemaker Pregnancy Implanted insulin pumps Inflamed areas, open wounds Cancer or tumors Tetany (convulsive muscle spasms) Circulatory insufficiency Febrile diseases Thromboses, varicose veins, venous inflammation...
IONTO-HF Description Device housing and control panel Fig. 9: Device housing and control panel (1) Housing (2) Reduce the intensity (3) Slider with intensity indicator (4) Increase the intensity (5) Turn the device on or off / Start or stop treatment HF wand Fig.
Set the device up on a surface which is level, solid and heat resistant. Don't set the device on a towel or blanket. Ensure that the ventilation slots are free and not covered. If you own several IONTO-COMED ® Essential Line devices, you can stack up to 3 devices on top of one another.
IONTO-HF Connecting the HF wand To connect the HF wand to the device: Connect the HF wand cable to the jack on the back of the device. Then the HF wand is connected to the device. Operation Device NOTE Potentially wet glass electrode.
IONTO-HF Treatment NOTE High temperature difference with certain surfaces. This results in damage to the electrode. Don't place the glass electrode onto a cold surface (e.g. marble, metal, • etc.) after the treatment. NOTE Static discharge if the glass electrode comes into contact with other electrical devices.
IONTO-HF Treatment settings Risk of burns. This can result in minor injuries. CAUTION If you have disinfected the glass electrode or the skin, wait 5 minutes • before applying the glass electrode to the skin to perform treatment. Adjusting the intensity INFO Always turn the HF wand off when you apply the glass electrode to the skin or remove it from the skin.
IONTO-HF Cleaning and care Danger due to electrical shocks. These can cause deadly injuries. WARNING Each time before cleaning the device, turn it off and pull the power plug. • Housing and HF wand Cleaning NOTE Incorrect cleaning and care can result in damage to the device. This causes housing damage.
IONTO-HF Cleaning To clean the glass electrode: Remove product residue. Disinfect the glass electrode with a disinfectant wipe. Allow the glass electrode to dry. Then the glass electrode is cleaned. INFO We recommend the wipe disinfectant Bacillol Tissues (item no. 9220.502). Scope of delivery Number Item number Item name...
IONTO-MESO SL IONTO-MESO SL Contraindications In general, only treat healthy people. Don't use the IONTO-MESO SL on the following areas and in case of the following indications: Bacterial infections (e.g. boils, carbuncle, tuberculosis) In the vicinity of skin damage (e.g. open wounds, inflammation) Blood clotting disorders Skin diseases (e.g.
IONTO-MESO SL Description Device housing and control panel Fig. 11: Device housing and control panel (1) Housing (2) Reduce the frequency (3) Slider with frequency indicator (4) Increase the frequency (5) Turn the device on or off / Start or stop treatment Handpiece Fig.
Set the device up on a surface which is level, solid and heat resistant. Don't set the device on a towel or blanket. Ensure that the ventilation slots are free and not covered. If you own several IONTO-COMED ® Essential Line devices, you can stack up to 3 devices on top of one another.
IONTO-MESO SL Screwing the MESO pad onto the handpiece NOTE Risk of damaging the MESO handpiece. This results in making the MESO hand- piece unusable. Never turn the device on unless a MESO-Pad has been screwed onto the • MESO handpiece. To screw the MESO-Pad onto the MESO handpiece: Fit the unused MESO-Pad into the opening on the MESO handpiece with the narrow end to- wards the handpiece.
IONTO-MESO SL Treatment settings Adjusting the frequency How high you want to set the frequency depends on how sensitive the skin being treated is. The higher the frequency setting you use, the more effectively the active ingredient is introduced into the skin, but the greater the amount of skin reddening.
IONTO-MESO SL Treatment Starting treatment NOTE Risk of damaging the MESO handpiece. This results in making the MESO hand- piece unusable. Never turn the device on unless a MESO-Pad has been screwed onto the • MESO handpiece. To start the treatment: ...
IONTO-MESO SL Cleaning and care Danger due to electrical shocks. These can cause deadly injuries. WARNING Each time before cleaning the device, turn it off and pull the power plug. • Housing Cleaning NOTE Incorrect cleaning and care can result in damage to the device. This causes housing damage.
IONTO-MESO SL Accessories Item number Item name 8433.101 IONTO-MESO Pad (disposable item, 8 pieces) 8433.142 Fruit acid exfoliate, 50 ml 8433.140 Anti-Aging Hyaluron Gel, 15 ml 8433.141 Final care cream, 30 ml 8826.1 Universal handpiece holder Technical data Item number: 8826.8433 Voltage: 230 Volt / 50 –...
IONTO-VAC SPRAY IONTO-VAC SPRAY Contraindications In general, only treat healthy people. Don't use the IONTO-VAC SPRAY on the following areas and in case of the following indications: In case of highly dilated small blood vessels (telangiectasia) On irritable skin On very flabby old skin On cortisone-damaged skin An inflamed areas, open wounds In case of doubt you should consult with a physician.
IONTO-VAC SPRAY Description Device housing and control panel Fig. 13: Device housing and control panel (1) Housing (2) Permanent function (3) Pattern function (4) Frequency (5) Reduce the intensity (6) Slider with intensity indicator (7) Increase the intensity (8) Turn the device on or off / Start or stop treatment Adapter for glass ventouses INFO...
IONTO-VAC SPRAY Spray bottle INFO The spray bottle isn't included in the standard scope of delivery. (12) Vacuum opening (13) Spray outlet (14) Connection for rubber hose (15) Container Fig. 15: Spray bottle Putting into operation Device Setting the device up The place where the IONTO-Vac Spray is set up must meet certain requirements.
IONTO-VAC SPRAY Connecting the device to the mains supply To connect the device to the mains supply: Plug one end of the power cable into the socket on the back of the device Plug the other end of the power cable into a pow- er outlet.
Then the new filter paper has been installed in the adapter for glass ventouses. Attaching glass ventouses to the adapter for glass ventouses ® Only use glass ventouses and suction cups from IONTO-COMED Ensure that the treatment hasn't been started. Slide the end of the attachment onto the thread up to the stop.
IONTO-VAC SPRAY Operation Device Turning the device on To turn the device on: Place the mains switch on the back of the device in position |. Then the device is in standby mode. Press the On/Off button (7). Then the device is turned on and the keypad backlighting is active. Placing the device in standby mode or turning it off You can turn the device off completely or place it in standby mode.
IONTO-VAC SPRAY Selecting the "Permanent" function With this function, the vacuum pump runs continuously at the specified intensity. Applications include deep cleaning, spraying and cupping massage. To select the "Permanent" function: To select the permanent function, press the "perm." button (2). Then proceed with the "Adjusting the intensity"...
IONTO-VAC SPRAY Regular maintenance and inspection The device doesn't require any maintenance if it is used properly and as intended. Repairs may only be performed by authorized specialists from the manufacturer. Modifications or repairs which were not performed by authorized specialists release the manufacturer from all war- ranty and liability obligations.
IONTO-VAC SPRAY Adapter for glass ventouses Cleaning NOTE Incorrect cleaning and care can result in damage to the device. This causes damage to the adapter for glass ventouses. Don’t use any aggressive or abrasive cleaning agents. Never clean the • adapter for glass ventouses in chemicals or an ultrasonic bath.
IONTO-VAC SPRAY Scope of delivery Number Item number Item name 8826.8513 IONTO-VAC SPRAY Vac handpiece without adapter Hoses 8362.002 10 x filter papers Accessories Item number Item name 8362 Adapter, holder for the ventouses and suction cups 32721 Hose, 1.20 m long 8362.002 Filter papers, 1 pack of 10 pieces for the adapter 9223.91...
Troubleshooting guide Troubleshooting guide Fault Cause Corrective action The device does not work. The power cord is not Check the power cord connection. connected properly. The plugs must be inserted firmly. The main switch on the Turn the mains switch on the back of back of the device isn't the device on.
Page 70
EG-KONFORMITÄTSERKLÄRUNG / DECLARATION OF CONFORMITY gemäß den Bestimmungen der EG-Richtlinie über / in accordance with the EU-Directives for Elektromagnetische Verträglichkeit 2004/108/EG / Electromagnetic Compatibility Directive 2004/108/EC Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 2006/95/EG / Low Voltage Directive 2006/95/EC Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und Elektronikgeräten 2011/65/EU / Restriction of Hazardous Substances Directive 2011/65/EU Hersteller / Manufacturer:...