Download Print this page

Gespasa EA-88 Instruction Manual

0.74 kw 230 vac

Advertisement

Quick Links

Tel. ++34(9)73 451072
Fax ++34(9)73 445000 – 448400
Partida Horta d'Amunt, s/n –Apartado de Correos nº 149
25600 BALAGUER (Lleida)
E-mail: gespasa@gespasa.es – Internet: http://www.gespasa.es
DESCRIPTION
2
SCREW M-6x25 DIN. 912
3
RETAINER 11.7x16.9x2.62
4
ALUMINIUM COVER
5
PUMP BODY JOINT 56 x 2
6
SCREW M-5x25 DIN. 912
7+8 DRIVE SHAFT Ø12x64.5 + GEAR
9
BUSH Ø12x16x12
10
BRASS PUMP BODY
18
LAYSHAFT Ø12x42 + GEAR
21
WHITE BY-PASS VALVE 10.5x35
1. TECHNICAL FEATURES
- EA-88 0.74 kW Self-suction Gear Pump
- It is suitable for the oil transfer, till density SAE-140
- Free flow: 20-25 l/min (SAE 20/50W at 25 ºC)
- It has recirculation by-pass valve.
- Motor: 0.74 kW Self-ventilated. 230 VAC 50/60 Hz Single-phase
- Level noise: L
> 85 dBA
EQA
- IP-55 Protection
- Motor equipped with thermal protection
- By-pass pressure: 9-10 bar
- Consumption: 4-6 A
- 1,500 rpm
- Inlet/Outlet tube: 1/2" GAS (BSP)
EA-88 PT 0.74 kW 230 VAC
INSTRUCTION MANUAL
WARRANTY AND CONFORMITY DECLARATION
CODE
805400007
22
11x12x38 BY-PASS SPRING
804600001
23
D.13x2 NBR JOINT
030001016
24
SPECIAL BY-PASS BULL PLUG 3/8"
28
803100021
230 VAC (3 m) CONNECTION CABLE WITH INJECTED PLUG
805400006
30
CONDENSER 32 μF/450 VAC
030002020
32
VENTILATOR COVER
030002014
33
CONNECTION BOX
030002001
34
ON/OFF IP-55 SWITCH
030002019
35
VENTILATOR
805606104
36
MOTOR 0.74 kW WITH THERMAL PROTECTION
IMPORTANT:
Valid flows without outlet nozzles with SAE 20-50 W at 25 ºC. With
nozzle, the flow is reduced according to the retention that it makes.
- ON/OFF Switch
- 230 VAC (3 m) connection cable with injected plug
DESCRIPTION
CODE
030702005
803100132
030002108
800900010
802000005
030701102
030701103
030001404
030701105
030702001
M-53

Advertisement

loading
Need help?

Need help?

Do you have a question about the EA-88 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gespasa EA-88

  • Page 1 MOTOR 0.74 kW WITH THERMAL PROTECTION 030702001 1. TECHNICAL FEATURES - EA-88 0.74 kW Self-suction Gear Pump IMPORTANT: - It is suitable for the oil transfer, till density SAE-140 Valid flows without outlet nozzles with SAE 20-50 W at 25 ºC. With - Free flow: 20-25 l/min (SAE 20/50W at 25 ºC)
  • Page 2 3.5. The EA-88 0.74 kW and SEA-88 0.74 kW pumps are tested in a self-suction of 2.5 m in depth. At major depth, with or without meter, it is advisable to install a retention valve with filter. The retention valve must be suitable for oil.
  • Page 3 EA-88 PT 0.74 kW INSTRUCTION MANUAL ATTENTION: Make sure that neither sealing liquids nor Teflon tapes go into the pump inner. If so, the pump or the bypass can be blocked. - Adjust the delivery hose to the pump outlet.
  • Page 4 EA-88 PT 0.74 kW INSTRUCTION MANUAL 9. WARRANTY 1. All the products manufactured by TOT COMERCIAL SA have a WARRANTY of 12 (twelve) months from their purchase, against any manufacturing defect. 2. TOT COMERCIAL SA guarantees, in the warranty period, the change/the devolution of the defective part or product. This material must be sent with prepaid freight to our factory or any appointed technical service.

This manual is also suitable for: