Improper installation, improper operation, and malfunction of a peripheral device. z Contamination with hazardous substances or radiation. z Alterations to the product without express written consent from Renogy. 1.1. Symbols Used The following symbols are used throughout the user manual to highlight important information.
2. General Information 2.1. Introduction A RENOGY ANL Fuse Set w/ Fuse contains a Renogy ANL fuse and an ANL Fuse Cover. The fuse set offers complete protection to your system, protects your charge controller, battery, inverter, and connecting wires from over-current, and ensures you get the longevity out of your system as expected.
3.2. Dimensions Dimension tolerance: ±0.2 in (0.5 mm) ANL Fuse Set w/ Fuse & ANL Fuse Cover █ 1.17 in (29.8 mm) 4.02 in (102 mm) 1.48 in 1.15 in (37.5 mm) (29.2 mm) 4.88 in (124 mm) 0.93 in (23.7 mm) ANL Fuse Set w/ Fuse Weight: 1.54 gr / 0.1 g 1.48 in...
4. Get to Know ANL Fuse This manual takes an ANL Fuse Set w/ Fuse as an example. A Renogy ANL Fuse Set includes one ANL fuse and fuse cover. Cover Nut (M8) Spring Washer Nut (M8) Flat Washer Spring Washer...
5. Installation 5.1. Required Tools Prior to installing and configuring the ANL fuse, prepare the recommended tools. Insulating Gloves Wrench (17/32 in) 5.2. Inspection Prior to installation, verify ANL fuse and set terminals exhibit no corrosion (white/green oxidation), pitting, or deformation. Verify the ANL fuse is intact with no signs of tripping, loose connections, or corrosion.
5.4. Installation Instructions Install all components in the exact order shown in the illustration below. Ring terminals sized for M8 studs (M8-M10 acceptable). Tighten the nuts to 70.8 in•lbs (8 N•m). 70.8 in·lbs (8 N·m) — 7 —...
6. Components Time-current curves – average melt: Current (Ampere) 7. Functional Characteristics A fuse does not blow when the current reaches its rated current. It is designed to pass its rated current without opening. A fuse will take varying times to blow under different conditions. A fuse will pass significantly more than its rated current for a very short time.
Alternatively, you can size a fuse based on the current going through the fuse. For details, see Size Fuses or Circuit Breakers for a Solar Power System at Renogy Learning Center. Does the fuse or fuse set come with a fuse cable? █...
Questionnaire Investigation To explore more possibilities of solar systems, visit Renogy Learning Center at: renogy.com/learning-center For technical questions about your product in the U.S., contact the Renogy technical support team through: renogy.com/contact-us 1(909)2877111 For technical support outside the U.S., visit the local website below: Canada ca.renogy.com...
Page 14
Save 105 gallons of water from being consumed Renogy Power PLUS Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.
Need help?
Do you have a question about the RNG-SET-ANLX0 and is the answer not in the manual?