Page 1
CLASSIC Series | Service Manual TRICOR® How to check the electrical resistance of the coils / the temperature sensor (non-Ex, compact DC-Version)
Page 2
Version Manual-Version TCE_8000_CLASSIC_Electrical_Resistance_SM_EN_191009_E006 SW-Version This manual is valid for Main SW: Mv3.40 and higher Display SW: Dv3.40 and higher CLASSIC Series | Service Manual | Version: TCE_8000_CLASSIC_Electrical_Resistance_SM_EN_191009_E006...
Page 3
Index Index TAKE OFF THE BLUE BACKCOVER OF THE TCE ..............4 PLUG OFF THE WHITE 10-PIN-PLUG ................... 4 MEASURE THE ELECTRICAL RESISTANCE OF THE COILS ............5 PIN ASSIGNMENT ......................5 CLASSIC Series | Instruction Manual | Version: TCE_8000_CLASSIC_Electrical_Resistance_SM_EN_191009_E006...
Take off the blue backcover of the TCE Take off the blue backcover of the TCE and unscrew the four bolts to release the mainboard. Plug off the white 10-pin-plug CLASSIC Series | Service Manual | Version: TCE_8000_CLASSIC_Electrical_Resistance_SM_EN_191009_E006...
- purple 1 and 2 120 Ohm orange - red 3 and 4 120 Ohm blue - yellow 5 and 6 120 Ohm brown - green 7 and 8 1090 Ohm Pin Assignment CLASSIC Series | Instruction Manual | Version: TCE_8000_CLASSIC_Electrical_Resistance_SM_EN_191009_E006...
Page 6
Contact NORTH & SOUTH AMERICA EUROPE (ROW) AW Lake Company KEM Küppers Elektromechanik GmbH 2440 W. Corporate Preserve Dr. #600 Liebigstraße 5 Oak Creek WI 53154 | USA 85757 Karlsfeld | Germany +1 414 574 4300 +49 8131 59391-100 sales@aw-lake.com sales@kem-kueppers.com www.aw-lake.com www.kem-kueppers.com...