Advertisement

Quick Links

CM-eXT2-07-R-DE/DF
CM-eXT2-10W-R(H)-DE/DF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Xpanel and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cimon Xpanel

  • Page 1 CM-eXT2-07-R-DE/DF • CM-eXT2-10W-R(H)-DE/DF •...
  • Page 2: Table Of Contents

    CONTENTS Essential Safety Precautions ……………………………… 3 General Safety Precautions ………………………………… 6 Package Contents …………………………………………… 7 Dimensio ns ………………………………………………… 8 Interfaces …………………………………………………… 9 Installation …………………………………………………… 13 Wiring & Power Supply Cautions ………………………… 15 Grounding Cautions ………………………………………… 16 Specifications ………………………………………………… 17 Project Download …………………………………………… 21 Products Warranty………………………………………………...
  • Page 3: Essential Safety Precautions

    Precautions for installation • Please do not disassemble or modify the Xpanel. It will void the warranty and may cause an electric shock. • This version of the Xpanel is not rated for flammable environments. Do not use this Xpanel around flammable gases.
  • Page 4 Maintenance • The Xpanel uses a lithium battery to back up the internal clock. Do not replace this battery by yourself because it may cause an explosion. If the battery needs to be replaced, please contact your local service center.
  • Page 5 DO NOT daisy chain the FG wires between devices. • Correctly wire the Xpanel, be sure that the rated voltage and terminal layout are within the designated range. If the voltage supplied differs from the rated voltage, or incorrect wiring or grounding is performed, it may cause a fire or unit malfunction and it will void the warranty.
  • Page 6: General Safety Precautions

    UV rays may cause the LCD display’s quality to deteriorate. • After turning the Xpanel OFF, be sure to wait a few seconds before turning it ON again. If the Xpanel started too soon, it may not start up correctly.
  • Page 7: Package Contents

    Package Contents ▪ The following items are contained in the package of the Xpanel. Before using the Xpanel, please confirm that all items listed here are present. Xpanel Unit – 1 EA Fastener – 4 EA (7”), 10 EA (10”) ●...
  • Page 8: Dimensions

    Dimensions Dimensions Unit: mm - 8 -...
  • Page 9: Interfaces

    Interfaces • eXT2-xx-xx-DE • eXT2-xx-xx-DF Name Description Micro SD Socket TOOL USB Device (USB 2.0 Type-C) AUDIO Audio Out (3.5mm Stereo) USB Host (USB 2.0 Type-A) - 9 -...
  • Page 10 Interfaces Interfaces COM1: RS-422/485 ● This interface is used to connect the Xpanel and target device via an RS-422/485 cable. Connector Pin No. Name Description Receive Data B Receive Data A Ground Send Data B Send Data A ● In case of RS - 485 cable (2wire) connection, connect only both SDA and SDB lines.
  • Page 11 Interfaces COM2: RS-232C ● This interface is used for the connection between Xpanel and the target device via an RS-232C cable. Connector Pin No. Name Description Receive Data Transmit Data Signal Ground Request To Send Clear To Send • Normal communication is not guaranteed when using USB connector as a communication port in ordinary times.
  • Page 12 Interfaces Ethernet ● This interface complies with the IEE802.3 for Ethernet (10/100/1000Base-T). RJ45 Connector RJ45 Jack Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3- Direct Cable: Host ↔...
  • Page 13: Installation

    Installation ● Create a panel cut and insert the Xpanel into the panel from the front. Unit: mm ● Attach the Installation Fasteners from inside of the panel. Insert each hook of fasteners into the slot and tighten it with a screwdriver.
  • Page 14 Installation ● For the performance and safe use of the equipment, please keep the distance between the back of the main unit and each all of the container at least 100 mm. ● VESA Mount Installation (- 07 and -DE models do not support VESA mount). Unit: mm - 14 -...
  • Page 15: Wiring & Power Supply Cautions

    ● When the FG terminal is connected, be sure the wire is grounded. Not grounding the Xpanel unit will result in excess noise and vibration. The torque required to tighten these screws is 0.678_0.813 lbf*ft ●...
  • Page 16: Grounding Cautions

    Inside the Xpanel unit, the SG (Signal Ground) and FG (Frame Ground) terminals are connected to each other. (10”) ● When grounding to the rear face FG terminal of the Xpanel, (on the Power Input Terminal Block), be sure to create an exclusive ground.
  • Page 17: Specifications

    Specifications - 17 -...
  • Page 18 Protocol), Fatek FBs, LSIS FNET (XGI/XGK), Mitsubishi MELSEC Ethernet, Modbus TCP Master, OPC UA Client, Omron FINS, Proface GPEthernet, Siemens S7 Client Device (Serial): CIMON PLC (HMI Protocol), LSIS Cnet (XGI/XGK), Mitsubishi MELSEC Serial, Modbus RTU Master, Omron HostLink, Panasonic FP7, Yokogawa FA M3, Allen Bradley...
  • Page 19 Protocol), Fatek FBs, LSIS FNET (XGI/XGK), Mitsubishi MELSEC Ethernet, Modbus TCP Master, OPC UA Client, Omron FINS, Proface GPEthernet, Siemens S7 Client Device (Serial): CIMON PLC (HMI Protocol), LSIS Cnet (XGI/XGK), Mitsubishi MELSEC Serial, Modbus RTU Master, Omron HostLink, Panasonic FP7, Yokogawa FA M3, Allen Bradley...
  • Page 20 Specifications Item Description DE : 0℃ – 65℃ / DF : -20℃ - 70℃ Operating Temperature -25℃ – 75℃ Storage Temperature 10 – 90% RH (below 29℃, not condensed) Operating Humidity 10 – 90% RH (below 39℃, not condensed) Storage Humidity 800 –...
  • Page 21: Project Download

    * This step is not required for project download via USB cable. In the Control Center, you can change the IP setting of Xpanel. Port 1 is assigned to the upper port, and Port 2 is assigned to the bottom port.
  • Page 22 Project Download Select the ‘Network Settings’ button in the Settings app. Enter the IP address, Subnet mask, and gateway in each field. Tap the ‘Apply and Save’ button to apply the network settings. ※ Please note that all the ports must not be configured on the same subnet mask. ※...
  • Page 23 ● Project Download Run CIMON Canvas and open the project. Go to [Tools] – [Connection Setup]. Select the target Xpanel from the list and press [Download Project]. While using a USB cable for project download, only one device per connection is available.
  • Page 24 Project Download ● Download project to the Removable Disk (Xpanel → USB) Connect a removable disk to the PC and move the CIMON Canvas project file (.cnvs) to the removable disk. ● Upload the project from a removable disk to Xpanel Connect the removable disk to the Xpanel.
  • Page 25 Project Download Choose the project file from the file browser displayed below the [Select Project]. Then press [Transfer Project] to copy the project. - 25 -...
  • Page 26: Products Warranty

    Products, not recommended in writing for interconnection by CIMON. In no event will CIMON be liable, whether in contract, tort, or under any other legal theory, for lost profits or revenues, loss of use, or similar economic loss for any...
  • Page 27 COMPLIANCE WITH ANY LEGAL OBLIGATIONS, LAWS, OR REGULATIONS. LIMITATION OF LIABILITY AND INDEMNITY: TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE ENTIRE LIABILITY OF CIMON, ITS AFFILIATES, AND SUPPLIERS FOR ALL MATTERS OR CLAIMS RELATING TO THIS AGREEMENT SHALL BE LIMITED TO THE AMOUNT YOU PAID FOR THE PRODUCTS DURING THE TWELVE (12) MONTHS BEFORE SUCH CLAIM.
  • Page 28 Products Warranty SUBJECT TO APPLICABLE LAW, CIMON, ITS AFFILIATES, AND SUPPLIERS ARE NOT LIABLE FOR ANY OF THE FOLLOWING: (A) INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES; (B) DAMAGES RELATING TO FAILURES OF TELECOMMUNICATIONS, THE INTERNET, ELECTRONIC COMMUNICATIONS, CORRUPTION, SECURITY, LOSS OR THEFT OF DATA, VIRUSES, SPYWARE, LOSS OF BUSINESS, REVENUE, PROFITS OR INVESTMENT, OR USE OF SOFTWARE OR HARDWARE THAT DOES NOT MEET CIMON SYSTEM REQUIREMENTS.
  • Page 29 MEMO - 29 -...
  • Page 30 MEMO - 30 -...
  • Page 31 MEMO - 31 -...
  • Page 32 Korea Address #1008 Office Bld., Signature Gwang-gyo 37, Poeun-daero 59beon-gil, Suji-gu, Yongin-si, Gyeonggi-do, Republic of Korea, 16864 Tel. +82-31-780-1039 USA Address CIMON Inc. 2435 W. Horizon Ridge Pkwy, #100, Henderson, NV 89052 Tel. +1-702-820-1060 Homepage: www.cimon.com Version: 1.0 Revision: Nov, 2024...

Table of Contents