RFPA
T E C H N I C A L M A N U A L
Radio panic button
RFPA is a panic button with a detachable lanyard.
Pressing the red button generates a "PANIC" type
event in the control panel that can be forwarded to
the various communication carriers integrated into
the control panel.
DESCRIPTION
5
1. Panic alarm button
2. Panic alarm button
3. Not used
4. Not used
5. 3-Colour LED
TECHNICAL SPECIFICATIONS
RF communication
Low voltage threshold 2.4 V
Current absorbed (TX
/ Standby)
EMC immunity EN 50130-4
Operating temperature
Dimensions 58 x 27 x 10 mm
1
RECORDING
2
Refer to the full control panel programming
3
manual for further information.
4
√ Make sure the radio control has not been
registered previously. If it has, follow the reset
procedure.
1. Access the radio control registration menu.
2. Select the radio control you want to register
and start the acquisition phase.
3. Press any key once.
»
The red LED flashes slowly while waiting
for the control panel to confirm acquisition.
»
The LED displays the acquisition result and
provides signal (RSSI) indication:
3 green flashes: stable connection
3 yellow flashes: unstable connection
3 red flashes: device not registered.
DEVICE RESET
f Press and hold keys 1 and 4 until the red LED
is steadily lit. While the red LED is lit, press key
4 once.
»
The green LED confirms correct completion of
a reset with three short flashes.
Bidirectional / 868.05 -
type
869.95 MHz
Battery CR2032
12 mA / 2 μA
-10 to 50°C
range

Advertisement

loading
Need help?

Need help?

Do you have a question about the RFPA and is the answer not in the manual?

Questions and answers

Summary of Contents for Comelit RFPA

  • Page 1 RF communication Bidirectional / 868.05 - type 869.95 MHz RFPA is a panic button with a detachable lanyard. Battery CR2032 Pressing the red button generates a “PANIC” type Low voltage threshold 2.4 V event in the control panel that can be forwarded to...
  • Page 2 CHANGING THE BATTERY DEVICE SETTINGS Refer to the full control panel programming manuals for further details. Art. RFPA is configured as a panic button by default. If the red key is pressed, an emergency alarm will be triggered LED INDICATIONS:...