RAPTOR G2 G2 MANUAL - HIGH PRESSURE CLEANER
HIGH PRESSURE WATER CLEANER
Cold Water
Record Serial Number below and retain product serial number which is
located on nameplate.
UNIT SERIAL NO.
ENGINE SERIAL NO.
PURCHASE DATE
Petrol Driven
ENGLISH
VERSION
V3.0 - 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Raptor G2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JETWAY Raptor G2

  • Page 1 RAPTOR G2 G2 MANUAL - HIGH PRESSURE CLEANER ENGLISH VERSION WARNING! Read this Operator’s Manual carefully before using this machine. Failure understand and follow the contents of this manual may result in electrical shock, fire and/or serious personal injury. READ CAREFULLY...
  • Page 2 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER 18/19...
  • Page 3: Standard Equipment

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Raptor G2 Jnr Engine 2. Unloader Valve 3. High Pressure Outlet (connection to hose coupling) 4. Low Pressure Inlet (for tap connection) 5. Water Inlet Filter 6. Chemical Injector 7. Fuel Fill Point 8.
  • Page 4 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER 18/19...
  • Page 5 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Raptor G2 Engine 2. Unloader Valve 3. High Pressure Outlet (connection to hose coupling) 4. Low Pressure Inlet (for tap connection) 5. Water Inlet Filter 6. Chemical Injector 7. Fuel Fill Point 8. Engine Controls 9.
  • Page 6: Table Of Contents

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Table of Contents Safety Symbols General Safety Rules Work Area Safety Personal Safety Pressure Cleaner Use & Care Service High Pressure Cleaning Safety Description, Specifications And Standard Equipment Description Specifications Standard Equipment Machine Assembly & Operation...
  • Page 7: Safety Symbols

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Safety Symbols In this operator’s manual and on the product, safety symbols and signal words are used to communicate important safety information. This section is provided to improve understanding of these signal words and symbols.
  • Page 8: General Safety Rules

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Service General Safety Rules • Pressure cleaner service must be performed only by qualified repair personnel. Service or maintenance WARNING performed by unqualified personnel could result in a risk of injury. Read and understand all instructions. Failure to follow •...
  • Page 9: Description, Specifications And Standard Equipment

    Do not spill fuel on or near exhaust take extra care in the refueling process as vapors or liquid can combust due to heat. Figure.2 - Raptor G2 & Raptor G2 Jnr High Pressure Cleaners • Hot surfaces can cause burns and fire. Keep body parts and flammable material away from hot surfaces.
  • Page 10: Machine Assembly & Operation

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER The machine serial number is located on the frame. The Make sure that the engine switch is in the OFF position. first letter & digits indicate the year and month of the manufacture. (G = 2023 (Year), 4 = April (Month)).
  • Page 11: Machine And Work Area Set-Up

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Machine and Work Area Set-up WARNING Always wear safety glasses, gloves and other appropriate protective equipment when setting up your pressure cleaner. Rubber soled, non-slip shoes can help prevent slipping on wet surfaces.
  • Page 12: Water Supply

    Attach the gun to the high pressure hose via coupling system. 3. Attach the hose to the high pressure pump outlet. High Pressure Outlet Low Pressure Inlet Figure.7 - Raptor G2 Hose Reel Mounting Figure.8 - Raptor G2 High & Low Pressure Outlet/Inlet...
  • Page 13: Machine Shut Down

    05/02/21 18:27:31 32Z5F600_004 Some engine applications use a remote-mounted throttle control Avoid any areas or actions that expose you to carbon RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER rather than the engine-m ounted throttle lever show n here. Refer to monoxide.
  • Page 14: Hose Reel Brakde Adjustment

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Hose Reel Brake Adjustment Pump Lubrication/Maintenance The optional hose reel is equipped with an adjustable brake Check the pump oil level prior to each use. Place the unit to prevent the hose from playing off the reel under its own on a level surface.
  • Page 15: Preparing Pump For Cold Weather Storage

    At 1000 hours of use (less in severe use conditions) the addressed by this section should only be handled by an Raptor G2 should be taken to a Jetwave Independent authorized Jetwave service technician. Service Center for pump seal and valve service.
  • Page 16: Declaration Of Conformity

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Declaration of Conformity We hereby declare that the machine described below complies with the relevant basic safety and health requirements of the EU Directives listed below, both in its basic design and construction as well as in the version put into circulation by us.
  • Page 17 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Type Raptor G2 Jnr 200-11 Raptor G2 275-15 Code CW3000-11PX-G2 CW4000-15P-G2 Motor Honda Petrol GX200, single cylinder, 4-stroke GX390, single cylinder, 4-stroke Maximum torque at 3600rpm kW/HP 4.3 / 5.8 8.7 / 11.7...
  • Page 18 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Honda™ Petrol GX200 Engine Maintenance Schedule Based on the ‘Maintenance Schedule’ in the Honda™ Engine Manual, always refer to the included manual for more in depth safety, maintenance and operation procedures of the engine.
  • Page 19 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Honda™ Petrol GX390 Engine Maintenance Schedule Based on the ‘Maintenance Schedule’ in the Honda™ Engine Manual, always refer to the included manual for more in depth safety, maintenance and operation procedures of the engine.
  • Page 20 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Jetwave™ High Pressure Cleaner & Water Jetting System Maintenance Schedule Refer to the included manual for your high pressure cleaner or water jetting system for safety, pre-inspection, operation, shutdown and more procedures. Always use an approved Jetwave™ servicing agent who uses Genuine Jetwave parts, to ensure full warranty coverage, service records will need to be provided.
  • Page 21: Troubleshooting

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Trouble Shooting FAULT CAUSE SOLUTION Pump runs normally Pump is sucking air. Check that all hoses and fittings are airtight. but pressure does not Valves are worn or dirty. Check, clean or replace.
  • Page 22: Maintenance Log

    RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Time interval for checks and replacement listed above are for units subjected to normal operating conditions. Should the unit be subjected to abnormal conditions (eg heavy use, dirty water, extreme temperatures or conditions etc) times should be reduced accordingly.
  • Page 23 RAPTOR G2 MANUAL - HIGH PRESSURE CLEANER Maintenance Log Hour Meter Date Maintenance Performed Service Agent Reading...
  • Page 24 10-16 Smith Street, Thebarton, 5031 Adelaide, South Australia, AU +61 8 8371 3599 GROUP info@jetwavegroup.com jetwavegroup.com jetwave-group jetwavegroup jetwave.group jetwavegroup jetwavegroup Raptor G2 Manual Copyright © 2023 Jetwave Group Pty Ltd. All Rights Reserved. ®...