Operating instructions

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
2
2
2
2
2
2
3
4
4
5
5
5
5
6
6

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
8
authorized technical staff.
9
Only authorized specialists are permitted to install the device, to carry
9
out a test run and to perform work on the electrical installation.
9
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
following installation in the final product.
10
The locally applicable industrial safety regulations are always to be
10
observed when working on the device.
10
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W2D210-EB10-12 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst W2D210-EB10-12

  • Page 1: Table Of Contents

    Note the following when working on the device: ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 5.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions W2D210-EB10-12 WARNING 1.7 Emissions Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). → Wait five minutes after disconnecting the voltage at all poles Risk of noise-induced hearing loss before opening the device.
  • Page 3: Intended Use

    Operating instructions W2D210-EB10-12 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions W2D210-EB10-12 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Screw plug PG 13.5 (3x); tightening torque 1.9 Nm Screw plug PG 11 (2x); tightening torque 1.9 Nm Screw plug PG 36 (3x), tightening torque 3.9 Nm Direction of air flow "V", AS-BS...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M2D068-CF cycles. If you have special questions, consult ebm-papst for support. Phase ; Use the device in accordance with its degree of protection.
  • Page 6: Connection And Startup

    Operating instructions W2D210-EB10-12 4. CONNECTION AND STARTUP → Make sure the end of the cable is connected in a dry environment. 4.1 Mechanical connection Only connect the device to circuits that can be switched off with an all-pole disconnection switch.
  • Page 7 Operating instructions W2D210-EB10-12 4.3.1 Preparing cables for connection Only strip the cable as far as necessary, ensuring that the cable gland is sealed and there is no strain on the connections. For tightening torques, see Chapter 3.1 Product drawing. NOTE Tightness and strain relief are dependent on the cable used.
  • Page 8: Connection Diagram

    Operating instructions W2D210-EB10-12 4.4 Connection diagram Star connection, three-phase motor blue black brown green/yellow not used...
  • Page 9: Opening Additional Cable Glands

    Operating instructions W2D210-EB10-12 4.5 Opening additional cable glands NOTE Damage to the device from vibration A second cable gland opening can be made in the terminal box. Bearing damage, shorter service life WARNING → Low-vibration operation of the fan must be ensured over the In the event of a fault, the cable gland is energized entire speed control range.
  • Page 10: Cleaning

    6 months replace if damaged Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm-papst Mulfingen GmbH & Co. KG. Condensation Visual inspection At least every Open holes drainage holes 6 months ;...
  • Page 11 Operating instructions W2D210-EB10-12 Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal.