Digital input expansion module 12 channel (22 pages)
Summary of Contents for AOS AI-6-N2K
Page 1
Analog Input NMEA 2000 Device (6 Channel) AI-6-N2K Owner’s Manual June 2021 (2.0)
Page 2
Analog Input NMEA2000 Device (6 CH) – AI-06-N2K Across Ocean Systems Ltd. NOTES RECORD DATA BEFORE INSTALLATION FOR FUTURE REFERENCE Model #: Serial #: Date of Purchase: Date of Installation: AI-6-N2K 2 of 23...
Across Ocean Systems Ltd. (AOS) also reserves the right to change, or update, without notice, any technical information contained within this document.
• Do not carry out any modifications to the product. • Only use authentic AOS spare parts. • Observe all local regulations, directives and laws during the installation of this product. • All installation, commissioning, and maintenance work must only be conducted by qualified personnel.
Voltage and Current Compatibility: Confirm that the power source is compatible with the maximum voltage and current ratings of is product variant. Failure to do so could result in damage or fire. AI-6-N2K 6 of 23...
• 1x Analog Input NMEA2000 Device • 1x Quick Start Guide (soft copy available https://acrossoceansystems.com If any of these items are missing or damaged, please contact Across Ocean Systems Ltd. to arrange replacements. AI-6-N2K 8 of 23...
Use recommended M4 or #8-32 screws to secure it into place at each side. Do not over-tighten the screws as it can lead to damaging the enclosure. 3D M ODEL EFERENCE A 3D Model of the unit is available on demand. AI-6-N2K 9 of 23...
Figure 1: Digital Input Expansion Module Connector Layout Table 1: Connector List Connector Name Analog Input Bank #1 Connector Analog Input Bank #2 Connector Ground Reference #3 Connector NMEA 2000 M12 Connector AI-6-N2K 10 of 23...
Page 11
Table 4: Ground reference connector ❸ Digital Input Bank #3 Connector Pin Type Function Designator Reference Reference to Vessel ground Power 5V/100mA Supply to external sensors Reference Reference to Vessel ground Power AI-6-N2K 11 of 23...
Note that if voltage source is connected to the analog inputs to apply appropriate fuse protection (1A) to protect the wire and the source (ABYC standard calls for protection within 1’ from the source) Follow recommended wiring practices and standards as per relevant local codes. AI-6-N2K 12 of 23...
All six inputs will measure 0 to 32V DC with resolution of 5mV. Each output can be used independently of the others and can be setup to output different NMEA2000 PGN representing the sensors the it is measuring. AI-6-N2K 13 of 23...
Password = #Pulse-00000 Now your Six Analog Input Module web configuration is accessible via the browser on your computer or smart phone. Open your browser (Chrome works best) and type in the address bar the following address: http://10.10.200.200 AI-6-N2K 14 of 23...
Vessel Monitoring system or your MFD as there will be a direct reference to the devices you’ve chosen to monitor and you will not have to guess which input is for what… AI-6-N2K 15 of 23...
Page 16
Over the Air. When new firmware is available from Across Ocean Systems Ltd, download the new XXXXXXX.bin file save it to a folder that can be easily accessed with the device (smart phone or computer) that you are using to configure the sensor and tap/click on the button AI-6-N2K 16 of 23...
Page 17
Failing the upgrade will not harm or “brick” the device, but it will just require to repeat the upgrade procedure. If wrong firmware file is selected the device will display the a warning that the file is not correct file for the device you are trying to upgrade: AI-6-N2K 17 of 23...
Page 18
If power is disconnected from the device during this time, the new setting will be lost. DO NOT DISCONNECT the NMEA2000 connector before the new settings are applied and the System status reads OK (0000) AI-6-N2K 18 of 23...
If you encounter problems with the operation of your product, please refer to the trouble- shooting suggestions before contacting AOS for assistance. If the steps below do not resolve your issue, please reach out either AOS directly or our Dealers in your area.
If any part is found to be defective, AOS will replace said part FOB the AOS factory provided that any such defective part is returned by the Buyer with freight and applicable forwarding charges prepaid by the Buyer.
PGN60928 ISO Address Claim • PGN65240 Commanded Address • PGN126208 NMEA Request/Command/Acknowledge group function • PGN126464 PGN List (Transmit and Receive) • PGN126993 Heartbeat • PGN126996 Product information • PGN126998 Configuration information • PGN???? To follow AI-6-N2K 21 of 23...
Page 22
Analog Input NMEA2000 Device (6 CH) – AI-06-N2K Across Ocean Systems Ltd. Page Intentionally Left Blank AI-6-N2K 22 of 23...
Page 23
Across Ocean Systems Ltd. 313-131 West 4 Street North Vancouver, British Columbia, Canada, V7M 3C8 Sales Tel: +1-236-688-8948 Email: sales@acrossoceansystems.com Website: acrossoceansystems.com Made in Canada / Printed in Canada...
Need help?
Do you have a question about the AI-6-N2K and is the answer not in the manual?
Questions and answers