LIFT 1T Motor eléctrico de uso profesional USER MANUAL | MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR Versión Español | Tecshow 3BOX LZ...
⚫ About exception matters The company shall bear no liabilities for damages incurred by fire disasters, earthquake, lightning stroke and other natural disasters, third party's behaviors, other accidents, users' intension or faults, mis operation, and other usages beyond the environmental conditions for use. The company shall bear no liabilities for collateral damages incurred in the using process of the product or its unavailability.
Therefore, before using electric chain hoist, please read the content and precautions in the manual. 2 Safety Instructions If the electric chain hoist is used in a wrong way, the hoisted loads may fall, or other dangerous states may occur. Please be sure to read the user manual carefully, and ensure accurate usage before carrying out installation, operation, usage and maintenance inspection.
This indicates prohibition (i.e., things that shouldn't be done). Specific prohibition contents will be marked in the middle of the graphic mark or near it in the mode of graphics or texts. Prohibited (General prohibition) graphic mark is used in the user manual.
box in the installation of hoist. managers, or it is also applicable to consult with the nearby service provider. Do not extensively use limit switch device Do not shake too much while hoisting. Do not hoist while the hoisted weights are unbalanced. Prevent the electric chain hoist from falling.
Page 7
Prevent from encircling objects with the host chain of the hoist. Annually replace the chain of chain hoist under situations with impact effect and operating status with high using frequency. After the breakage of chains, prevent from automatically welding before use. Chains must be replaced in whole, rather than in parts.
Page 8
Please ensure that the interior wiring sequence for the extension line of hoist is consistent (keep the grounding wire unchanged, and L1L2L3 color sequence consistent at the two ends of the line). Open the main power switch, and keep the status of urgent stop and pop-up. Turn the general control knob to "1".
Before use, please read the instruction manual carefully, and carry out hoist operation after adjustment, to avoid danger. Product Diagram Name Quantity Name Quantity Name Quantity Auxiliary Shell 2 Screw contacts Electromagnet Stator Ballast ic brake gear Electromagnet 50*80*8 oil seal Rubber pad 2 ic brake lining Electromagnet...
Braking mesh Transformer enclosure 7 Overhaul 7.1 Daily inspection: Before starting daily operation, please firstly check the following items (A) Power supply; Whether the voltage is normal (B) Test "up and "down" functions under non-load status. (C) Whether the motor can operate normally. (D) Whether there are abnormal or excessive noise.
Page 11
Check whether the limit switch can operate normally, and after clearing objects inside the limit guide groove, apply a thin layer of lubricating oil, to ensure normal operation. (D) Tighten screws for power supply around the hoist. Inner Outer Inseam Working Test Diameter...
Page 12
Hoist operation power line actives limit protection failure function, so operation failure occurs. (2) Power supply fuse burns out or Check whether the current demand fits, replace no-fuse switch trips off suitable fuse or restart no-fuse switch (3) Fuse of the controller circuit Check and replace correct fuse burns out (4) Power line or electric wire...
(3) Rubber pad without oil plug Install correct oil plug rubber pad Replace new Rubber pad (4) Abrasion or poor quality of rubber pad Safety device, mechanical class and service life ⚫ Electromagnetic brake Electromagnetic brake is a unique brake design. It is featured by the immediate brake even when power cuts off under full load.
Page 14
Mechanical load brake can ensure slow decrease of speed under full load. Besides, it is independent of the electromagnetic brake. Even if the electromagnetic brake fails, the mechanical auxiliary brake can still slowly decrease the speed of the hoisted object. ⚫...
Page 15
This button is used to stop the hoist under emergencies. It is a red and mushroom-shaped button located at the top of the switch controller When pressing down the button, the power will be cut off, and the button will be blocked automatically.
Gears and parts are often under maximum 0.80≤K≤1.00 ≤0.12 0.12-0.25 Ultra-heavy load or almost reach to the maximum load 1Dm 1Cm 1Bm ⚫ Three-phased asynchronous squirrel-cage motor is selected as the hoisting motor, to ensure the output of constant torque by the motor Benchmark to select hoisting motor Specification level Intermittent use...
Lubricating load chain The lubricating degree of chain is an important factor influencing the service life of load chain, and we should periodically use lubricating oil to ensure effective and long service life. Hoist the chain vertically without loads. Wipe out dust and water spots on the chain. As shown in the following figure, carry out lubricating treatment for each link joint, the load pulley or empty pulley.
Deformation Whether there are distortion and deformation Hook phenomena Action Whether the rotary action is smooth Others Whether there are cracks or defects Elongation Visible abnormity in elongation Abrasion Wire diameter abrasion beyond the limit Deformation Visible deformation Chain Corrosion Obvious corrosion phenomenon Corrosion cracks Whether there are cracks...
Page 19
procedures from attaching to the load chain. • Please prevent the welding rods and welding electrode from touching the load chain. • Please do not use the load chain as the grounding for welding operation. Figure A In case of failing to follow these contents, this may cause death or serious injuries and other major accidents.
Page 20
prevention device) as shutdown method. • Please stop using when the friction clutch (overload limit device) starts to operate, and load hoisting fails. Danger • Please prevent from operating beyond the hoisting/descending scope. • If the bottom hook touches the body after dismantling the chain spring or rubber pad, the load chain may be broken after repeated operation of limit switch.
Page 21
• Please do not stand below the hoisted load. • Please prevent the load and hook slings, etc. from touching the chain box. Load chain falling may cause personal injuries. • When the limit switch (over-winding prevention device) starts to work, please stop hoisting operation immediately and Mandatory drop the load.