Download Print this page

RiDom Ri-RC-1i Installation Manual

Advertisement

Quick Links

Relay AC «Ri-RC-1i»
Installation guide
1 GENERAL INFORMATION
1.1 Relay AC «Ri-RC-1i» (hereinafter – Relay) is designed to control the
connection of external devices to the 230V AC power grid.
1.2 Relay works as part of the RiDom smart home security system,
communicating with the «Ri-HUB-1» control center (hereinafter referred
to as the Hub) via the «Ri-Contact-Ri» radio channel protocol.
1.3 The Relay does not require licensing or registration as a radio
frequency product.
1.4 The Relay is powered by AC mains with a nominal voltage of
110/230 V and a frequency of 50/60 Hz.
1.5 The Relay generates and provides transmission of the following
notifications over the air:
- Normal status;
- Case opening.
1.6 The Relay is designed for continuous 24/7 operation
1.7 The Replay is EMI resistant.
2 SPECIFICATIONS
Table 1
Parameter
Frequency range
Radiation power, no more
Power supply
Maximum power consumption
Maximum switching load current (with resistive load)
Protection class
Dimensions
Weight
Average service life
Operational conditions
Operating temperature range
Permissible air humidity at a temperature
of +40 °C, without moisture condensation
3 SCOPE OF SUPPLY
Table 2
Name
Relay AC «Ri-RC-1i»
Screw 3-3x30.016
Dowel NAT 5x25 SORMAT
Installation guide for the «Ri-RC-1i»
ATTENTION! Only persons with at least 3
group and those who have a permit to work with voltages up to
1000 V are allowed to perform the installation and maintenance
of the Relay.
4 SAFETY MEASURES
4.1 When installing and operating the Relay, the provisions of the «Safety
Rules for the Operation of Consumer Electrical Installations» should be
followed.
4.2 All installation work must be carried out only with the external power of.
865...867 MHz
25 mW
85–305 V,
50/60 Hz
1,5 VA
AC-1 active load
1750 VA
AC-3 electric motor
AC-15 contactor coils
315 VA
65х66х28 mm
8 years
-30... +55
Up to 93 %
safety qualification
rd
5 VIEW AND DESIGN
The Relay with the removed case cover is shown in Picture 1. At the base
of the case (1) the following elements are shown:
- Hole (7) for attaching the case cover;
- Two holes (2) for fastening the Relay to the mounting surface;
- Place (11) for laying the network wire.
On the following elements are shown on the printed circuit board (3):
- Antenna (4);
- Green indicator (5);
- Red indicator (6);
- Reset contacts (8);
- Tamper switch (9);
- Terminal block for connecting of the switched device (10);
- Terminal block L AC N for connecting of power (12).
6 INDICATION
Table 3
The Relay status
Value
Linking mode
Linking accomplished
Identification indication
7 A
Connection quality
400 W
7 CHOOSING THE PLACE OF INSTALLATION
IP20
The Relay should be mounted indoors only.
Do not install the Relay in the following places:
1. On massive metal structures and closer than 1 m to them;
0,2 kg
2. Closer than 1m to metal water pipes;
3. Near sources of radio interference;
4. Inside metal structures.
5. Outdoors.
6. In rooms with temperature and humidity outside the allowable.
С
о
8 CONNECTING THE RELAY TO THE SYSTEM
8.1 Open the case cover.
8.2 Apply 230V to the contacts L AC N.
8.3 Close the RESET contacts on the Relay board with a conductive
object for a few seconds.
8.4 Make sure that the indicator turns green intermittently («Linking»
mode).
Qty.
8.5 Open the RiDom application. In the My Devices tab, click
then
1 pc.
the prompts of the application.
2 pcs.
8.6 When successfully connected to the Hub, the Relay's indicator will
2 pcs.
turn red for 2-3 seconds, then you can see the Relay in the application,
1 copy
as well as all the corresponding information about the Relay.
Link mode time is limited to 100 seconds. To resume the «Linking» mode,
briefly close the «RESET» contacts with a screwdriver for 2-3 seconds.
8.7 Install the case cover back.
9 RADIO CONNECTION QUALITY EVALUATION
9.1 Place the configured Relay in the intended place of installation.
9.2 Click on the tamper switch and hold it for at least 3 seconds.
9.3 Release the tamper switch.
9.4 Control the quality of the Relay communication with the Hub by
LED indicators according to the Table 4.
Note – A delay for up to 4 seconds is possible before any indication.
1
2
3
4
5
6
IR-RK V10.2
RESET
L AC N
12
11
Picture 1 – «Ri-RC-1i», front view with removed case
Intermittent green LED light
Turning on the red LED for 2 seconds
Alternating green and red LEDs activation
Turned on
Turning on the red LED for 2 seconds
assessment
. Select «Ri-RC-1i» relay from the list of devices and follow
7
9
8
OUT
10
2
Indication
See Table 4
and

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ri-RC-1i and is the answer not in the manual?

Questions and answers

Summary of Contents for RiDom Ri-RC-1i

  • Page 1 1 GENERAL INFORMATION IR-RK V10.2 RESET 1.1 Relay AC «Ri-RC-1i» (hereinafter – Relay) is designed to control the connection of external devices to the 230V AC power grid. 1.2 Relay works as part of the RiDom smart home security system, communicating with the «Ri-HUB-1»...
  • Page 2 Note – The storage premises should not contain any current conducting dust, acid and alkali fumes, or corrosive or destroying insulation gases. RI-RC-1i 14 DISPOSAL INFORMATION 14.1 The Relay does not contain precious metals, hazardous or toxic substances that can harm human health or the environment, and does not pose a danger to life, human health and the environment at the end of its service life.