4420089 – Rev 20220628
USER INSTRUCTIONS
CAUTION. Carefully observe all the following installation
instructions to ensure personal safety.
The device is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lacking experience and knowledge. Do not allow children to
play with the fixed controls and keep any remote-control units
out of their reach.
Have installation checks performed periodically by qualified
personnel from a service centre authorised by the manufacturer.
Do not use if repair or adjustment is required.
CAUTION. Disconnect the power supply during cleaning or
maintenance operations. Do not use solvents or jets of water to
wash the appliance; the appliance should not be submerged in
water.
In the event of fault or malfunction, switch off the device at the
main switch. All repairs and adjustments must only be performed
by qualified personnel from a service centre authorised by the
manufacturer.
Always request exclusive use of original spare parts. Failure to
respect this condition could compromise safety and invalidate
the benefits contained in the warranty for the appliance. In the
event of any problems or queries, consult your agent or contact
the manufacturer directly.
Carefully preserve these instructions after installation.
The product must be disposed of in compliance with
local environmental regulations and not as household
waste.
Page 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MODIX 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for nekos MODIX 2

  • Page 1 The product must be disposed of in compliance with local environmental regulations and not as household waste. NEKOS S.r.l. - Via Capitoni, 7/5 - 36064 Colceresa – VI – ITALY +39 0424 411011 –  +39 0424 411013 - www.nekos.it - info@nekos.it 4420089 – Rev 20220628...
  • Page 2: Table Of Contents

    ATTENTION: Before installing this appliance, ensure all safety indications have been read carefully and understood in order to prevent nekos products have been manufactured in accordance with safety standards and contact with electricity, injury or any other incident. The manual should conforms to the stipulations of current standards in force.
  • Page 3: Construction And Regulatory References

    4. ID PLATE AND MARKING DATA G. Drill the box to allow passage of the connection cables in the desired position using a MODIX 2/4/6 stations have marking and are destined for use in the European Union Ø10 drill bit. Remove the electronic board from the box to avoid damaging it permanently without further requirements.
  • Page 4: Technical Operating Information

     The + (plus) and – (minus) keys pressed together are used to exit the programming The maximum output current of the MODIX 2-4-6 control unit is 10A, a limit determined by the internal protection of the battery charging module.
  • Page 5 -↑ +↓ ­ In11 - motor 1 Open ­ In12 - motor 1 Close Exit 1 Timer function F[0]. Set the action when active as follows:  0=none ­ In21 - motor 2 Open P105  1=open ­ In22 - motor 2 Close ...
  • Page 6 -↑ +↓ -↑ +↓ Exit 4 Rain sensor function (1 - 2) F[2]. Set the action when the input is P301 Exit 3 Work time (10 - 240) s F[60]. active, as follows:  0=none -↑ +↓ P404  1=open Exit 3 Reset time (0 - 60)min F[0] P302 ...
  • Page 7: Settable Functions

    -↑ +↓ -↑ +↓ Changes the association: PIK radio remote control channel No.  Motor P506 Exit 5 Aeration time (1-60)min F[10]. -↑ +↓ -↑ +↓ Exit 5 Single manual command functioning mode:  0=half-automatic mode Deletes 1 PIK radio remote control from the memory. P507 ...
  • Page 8: Saving A Pik Radio Remote Control

    100mA there. Please contact Nekos technical office to use rain sensors other than NSR1 6.3.7. Output ventilation time – Parameters P106, P206, P306, P406, P506 ­...
  • Page 9: Saving A Radio Remote Control Without Access To The Board

    The remote electronic control provided with K_R units is equipped with 30 selectable The programming is achieved by carrying out the following procedure: channels. Each command channel is connected to one unit exit. Opening/closure/stop of  Equip yourself with the PIK radio remote control to be saved and set it on any channel each exit can be commanded using arrow ▲/▼...
  • Page 10: Electrical Connection Diagrams

    ELECTRICAL CONNECTION DIAGRAMS Electrical connection diagram – Modix 6 Electrical connection diagram – Modix 2 1 3 1 4 1 5 1 6 17 1 8 1 9 2 0 21 2 2 2 3 24 CONTROL 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2...
  • Page 11: Environmental Protection

    Electrical connection diagram – 24V expansion module The purchaser is not entitled to any reimbursement for eventual direct or indirect damage or other expenses incurred. Attempt to repair by personnel unauthorised by the manufacture shall render the warranty null and invalid. The warranty does not cover fragile parts or parts subject to natural wear and tear or corrosion, overload, however temporary etc.
  • Page 12: Declaration Of Conformity

    11. DECLARATION OF CONFORMITY The undersigned, Company name: NEKOS S.r.l Via Capitoni, 7/5 36064 Colceresa VI Postal address: Postcode and city: Telephone number: +39 0424 411011 E-mail address: info@nekos.it declare that the document is issued under our sole responsibility and belongs to the following product:...