Advertisement

Quick Links

User & Installation
Manual
BS EN 13240:2001 + A2:2004
Tested as intermittent
appliances burning wood logs
Version_2_02_2024_rondo
MODEL:
Rondo with Door
Rondo with Pedestal
Rondo with Log Store
www.mi-flues.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rondo with Door and is the answer not in the manual?

Questions and answers

Summary of Contents for Mi-Fires Rondo with Door

  • Page 1 User & Installation Manual MODEL: Rondo with Door BS EN 13240:2001 + A2:2004 Rondo with Pedestal Tested as intermittent appliances burning wood logs Rondo with Log Store www.mi-flues.com Version_2_02_2024_rondo...
  • Page 2 At Mi-Fires we believe the best way to enjoy the maximum benefit from your new stove is that it should be installed by a fully trained competent stove installer that can identify the optimal way to install and commission your new appliance.
  • Page 3: Table Of Contents

    4.1 Chimney Sweeping 4.2 Combustion chamber 4.3 Glass 4.4 Gaskets 4.5 Ash 4.6 Cleaning the stove 4.7 Spare Parts 5. WARRANTY & RECORDING 5.1 Mi-Fires Stoves Warranty 5.2 Installer details and Handover checklist 5.3 Annual Service / Sweeping record 5.4 Warranty Registration...
  • Page 4: Compliance

    1. Compliance 1.1 Dimensions Rondo with Door Rondo with Pedestal Rondo with Log Store...
  • Page 5 1.2 Technical data This appliance designed for intermittent operation only RONDO RONDO RONDO WITH WITH DOOR WITH LOG PEDESTAL STORE Product code 149-RO-D 149-RO-LS 149-RO-P Nominal Heat Output Flue outlet diameter Measurements (Height x Width x 956 x 487 x 956 x 487 x 971 x 487 x Depth)
  • Page 6: Transportation

    2. Installation of the stove freestanding area and within a fire place chamber. 2.1 Pre-Installation Mi-Fires freestanding stoves do not require a It is a LEGAL requirement under England constructional hearth beneath them as they and Wales building regulations that the do not cause the floor temperature to exceed...
  • Page 7: Flue Requirements

    DISTANCES TO COMBUSTIBLES MATERIALS RONDO RONDO RONDO WITH LOG WITH WITH DOOR STORE PEDESTAL Back wall (mm) Side wall (mm) Hearth projection front (mm) Hearth projection side (mm) Distance to furniture (front) (mm) 1200 1200 1200 Recommended distances to combustibles 2.3 Flue Requirements The chimney must also be free from cracks and blockages.
  • Page 8: Ventilation / Fresh Air Supply

    Clean Air Act requirements. in England and Wales unless the appliance The Rondo with Door, Rondo with Log Store nominal rated output is greater than 5kW. and Rondo with Pedestal stoves have been Extractor Fan Warning: There must not be an recommended as suitable for use in smoke extractor fan fitted in the same room as the...
  • Page 9: Lighting And Using The Stove

    3.2 The Stove Air Controls ■ Never use easily combustible fluids to Your Mi-Fires stove is fitted with a very simple light the fire in the wood burning stove. one lever air control, this allows you to regulate the amount of combustion air that enters your ■...
  • Page 10: Lighting A Fire In The Wood Burning Stove

    Burning small logs provides more powerful door closed, except for lighting and reloading, combustion than burning large logs as failure to close the door during operation can the surface area is greater and more gas result in fume spillage. is released. The amount of wood in the WARNING: Properly installed, operated and combustion chamber is another factor that maintained this appliance will not emit fumes...
  • Page 11: Cleaning And Maintenance

    Wood and how intensively the stove is used. that is not properly dry (‘dry’ is considered to be Spare parts are available from Mi-Fires directly less than 20% internal moisture content) uses or from your local Mi-Fires dealer.
  • Page 12: Warranty & Recording

    5. Warranty & Recording Exclusions & Limitations The warranty will be void if the appliance is 5.1 Mi-Fires Stoves Warranty not installed by a suitably qualified person, or Terms & Conditions is not installed in accordance with the current Firebox...
  • Page 13: Installer Details And Handover Checklist

    5.2 Installer details and hand over checklist Dealers Contact Details HETAS Number Date of Purchase Installers Contact Details HETAS Number Date of Installation Appliance serial number Flue draft test complete? Pascal Rating Type of Flue System Unlined Masonry Diameter Manufacturer Installation instructions left with customer Lined Masonry Diameter...
  • Page 14: Annual Service / Sweeping Record

    5.3 Annual service / Sweeping record CERTIFICATE DATE ENGINEER/SWEEP NAME RETAINED...
  • Page 15: Warranty Registration

    5.4 Warranty registration To validate and start your warranty please fill out this form and return it to: MI-Flues Ltd Mi-Fires Warranty Registration Taymin Business Park, Mitcham Road, Blackpool, Lancashire, FY4 4QN YOUR DETAILS Name Address Postcode Contact Number Email...
  • Page 16 MI-Flues Ltd Taymin Business Park Mitcham Road Blackpool, Lancashire sales@mi-flues.com FY4 4QN sales@Mi-Fires.com www.mi-flues.com...

Table of Contents