Wolf p-AK-MSMO Instruction Manual
Wolf p-AK-MSMO Instruction Manual

Wolf p-AK-MSMO Instruction Manual

Filling-pressure monitoring system with automatic regulation of the filling pressure and power of p-joint-sealing cushions/v (valve) during installation

Advertisement

Filling-pressure monitoring system with automatic regulation of
the filling pressure and power of p-joint-sealing cushions/V (valve)
Filling-pressure monitoring
system with automatic
regulation of the filling pressure
and power of p-joint-sealing
cushions (valve)
Ensures a controlled pressure-
filling of 150 mbar to 300 mbar
from below during installation
General
The sealing efficiency and service lifetime of p-joint-sealing systems are directly related to filling
pressure, which is temperature-dependent, and lateral movement along the x-axis.
It is therefore important to:
-
adhere strictly to the installation specification, VO 60.02 Pressure-filling of Sealing Cushions with a
Valve for Expansion and Movement Joints, and to provide proof of tightness.
reach the permissible pressure filling for reusable p-seals for movement joints (type L: 300 – 350
-
mbar and type S: 150 – 200 mbar (20°C +10°C)) during installation. This can be achieved by
using the filling-pressure monitoring system Art. No. 86.01 p-AK-MSMO, for example.
-
set up the filling-pressure monitoring system Art. No. 86.01 p-AK-MSMO for permanent
regulation of filling pressure and power after installation (because pressure fluctuates as a
consequence of movement along the X-axis in summer and winter, amongst other factors). Ceiling
or wall Installation is recommended.
carry out a visual inspection of the filling pressure (tightness) of the reusable movement-joint
-
p-seals in the course of routine joint inspections, adjusting the filling-pressure where necessary.
M:\PI\EN\86\E-PI_86.01_p-AK-MSMO_Monitoring.docx
Joint-sealing technology
p-AK-MSMO
during installation
26.03.2021
PI
86 | 01
Page 1 / 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the p-AK-MSMO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wolf p-AK-MSMO

  • Page 1 S: 150 – 200 mbar (20°C +10°C)) during installation. This can be achieved by using the filling-pressure monitoring system Art. No. 86.01 p-AK-MSMO, for example. set up the filling-pressure monitoring system Art. No. 86.01 p-AK-MSMO for permanent regulation of filling pressure and power after installation (because pressure fluctuates as a consequence of movement along the X-axis in summer and winter, amongst other factors).
  • Page 2: Technical Data

    Technical data 1 Precision pressure controller Without internal air consumption 0.1 to 1.0 bar Regulating area Operation Description Pressure setting can be - Precise pre-selection of Purity class 1 held by means of a locknut working pressure for compressed air in acc.
  • Page 3: Technical Specifications

    …. / Technical data 2 Pressure gauge with diaphragm capsule "Gas" With zero adjustment Optional overpressure and/or underpressure safety 10 x FSD (full scale deflection) Extremely low measuring range from 0/6 mbar GOSSTANDART-certified Application: Design: For gaseous dry media that do not attack Measuring element: Capsule spring, CuBE alloy copper alloys.
  • Page 4 Mode of operation of the p-AK-MSMO filling-pressure monitoring system 1. Components p-AK-MSMO Monitoring system (for pressure filling and monitoring) (For assembly unit: reusable p-joint-sealing system) Pressure inlet valve Precision pressure controller Pressure gauge Ø 100 mm 0–1000 mbar Connection: pneumatic tubing for connection to the reusable p-sealing system...
  • Page 5: Functional Example

    …/ Mode of operation of the p-AK-MSMO filling-pressure monitoring system 2. Functional example (Fibre Optics CT GmbH test setup No. 3, Test Report 263/ 2020) The following 3 reusable p-joint-sealing cushions (test samples) are connected to one another via the...
  • Page 6 …/ Mode of operation of the p-AK-MSMO filling-pressure monitoring system Example: Filling times for simultaneous inflation (Test diagrams taken from FibreOpticsCT GmbH Test setup No. 3 Filling times for test samples A and A Protocol No. 260.1 /2020) Filling times Test sample 5.1...
  • Page 7 …/ Mode of operation of the p-AK-MSMO filling-pressure monitoring system Example: Pressure force for the purpose of verifying tightness (Test diagrams taken from FibreOpticsCT GmbH Test setup No. 3 Test Report No. 263 /2020) Volume of the 3 sealing cushions: = 3.0 x 9 x 69 cm...
  • Page 8 Application of the p-AK-MSMO filling-pressure monitoring system (example) Art. No. 85.01 PaK tightness monitoring system p-AK-MSMO Filling-pressure monitoring system Pressure hose Art. No. 33 E-PAS-VAS, Pressure inlet valve example of length: 3m Precision pressure controller Pressure gauge Filling adapter, pressure hose with torque plug nipple Connection to the reusable p-seal Art.

Table of Contents