Installation Guide CONTENTS IMPORTANT SAFETY INSTRUCTIONS ........................2 Identification of Danger Levels ..........................2 BEFORE YOU BEGIN ............................... 2 Recommended Tools ..............................3 EQUIPMENT SIZING SPECIFICATIONS ........................3 VACUUM UNIT CLEARANCE REQUIREMENTS ....................... 4 VACUUM UNIT INSTALLATION ..........................5 Before Installation ..............................5 Single Vacuum Unit Installation ..........................5 Single Vacuum Unit - Overhead Intake 5 Single Vacuum Unit - Below Grade Intake 6...
2. Using a multimeter, check that the input voltage is within the specified operating range of 200-240 VAC for this equipment. Also confirm there is a proper ground connection according to electrical code. Electrical Specifications ADS V3 ADS V5 ADS V7...
40-104°F. Make any needed adjustments to the HVAC system or ventilation to maintain proper thermal conditions. For any ongoing temperature control issues, facility modifications may need to be considered. Recommended Tools To complete utility and accessory installations on ADS equipment per manufacturer specifications, the following tools should be readily available: ● Spirit level ●...
Installation Guide VACUUM UNIT CLEARANCE REQUIREMENTS Provide a minimum of 9 inches of clearance behind the vacuum unit and any rear obstructions. This clearance is needed for ventilation and access to the back panel. Allow at least 4 inches of clearance on each side of the vacuum unit, including between multiple adjacent vacuum units.
Installation Guide VACUUM UNIT INSTALLATION Proper ventilation is required Grab Points Provide at least 1 inch clearance between the bottom of the vacuum unit and the floor. This allows adequate air WARNING intake. Before Installation 1. Remove the product's outer packaging box. 2.
Installation Guide Single Vacuum Unit - Below Grade 7. Double check that ventilation openings are unobstructed. Blocked air flow leads to overheating and Intake pump damage. 8. Keep the area around the unit clean and free of clutter. The island setup places the vacuum unit in the room center. Obstructions increase fire hazards.
Page 9
Installation Guide ● Tee connectors ● Any fitting not explicitly approved by the manufacturer Connecting the Drain Hose to the Vacuum Unit 1. Use the provided hose clamp to securely fasten the drain hose to the drain outlet on the vacuum unit. Tighten the clamp sufficiently to prevent leakage.
Page 10
Installation Guide Connecting the Drain Hose to a Pipe Stub with an Air Gap 4. Measure and trim the drip leg hose to optimal length for proper routing to the floor drain. 1. Attach the drain hose to a pipe stub above the drain tile or sink to maintain an air gap.
Tandem Vacuum Units Installation Valve Airflow From the Operatories ADS dry vacuum system can be installed as tandem vacuum units (ADS V10 and ADS V14) to increase vacuum capacities. Optional Connect the 2" PVC Tandem vacuum units work as follows:...
Installation Guide Attaching and Leveling the Intake Manifold 1. Use the included brackets to mount the intake manifold assembly securely in the desired location. Tandem Vacuum Units - Below 2. Attach the brackets to a sturdy surface using appropriate hardware for the material (not included). Grade Intake 3.
Installation Guide Connecting the Intake Hose to the ● Use 3" to 2" reducer fittings to connect the 2" pipe into the 3" main exhaust line. Trunk Line ● Optional: Install drip leg fittings at low points to drain condensed moisture. The process for connecting the intake hose to the building's 3"...
Installation Guide stress on the connections. 5. Install a p-trap if connecting to a drain pipe. This prevents sewer gases from backing up into the system. Do not 3. Attach the drain hose to the drain pipe or receptacle trim the drain hose excessively. Some slack is needed to using the supplied hose clamp.
Installation Guide terminal strip, according to the following table. Brown To Device Yellow -Light +24 V Orange Run Signal To Remote Control Mfg/Wire Brown Yellow Orange (-Light) (+24 V) (Run Signal) Air Techniques Brown Yellow Orange C o n n e c t to Ground A-dec Gray...
Located on the internal circuit board, status lights provide real-time operational information to aid troubleshooting. To view indicators, remove the front service panel. The lights indicate current system conditions and modes. If the status lights do not resolve an observed issue, contact ADS technical support for assistance. www.adsdental.com...
Page 17
Installation Guide ACTIVATE RINSE ON_LINE TVS6 TVS5 TVS3 TVS4 TVS2 TVS1 AJAX_NEG_PRESSUER V2.0 220V_IN 8302700A 2023/12 BAT1 WARNING: HIGH VOLTAGE Status Lights on the Internal Circuit Board Mean This ... The ON light is on. The vacuum unit is connected to main power. The ACTIVATE light is on.