AUXILIARY HEATER Installation Manual Safety precautions & Installation Models: CH-PQEH05KW CH-PQEH10KW CH-PQEH15KW CH-PQEH20KW IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
Page 2
About the Company With more than 25 years of experience in air conditioning and ventilation, Cooper&Hunter is considered one of the HVAC leaders in the US market. Distributed in more than 55 countries worldwide, brand dedicated technological innovation consumer-driven product development, while generating HVAC equipment that adheres to the highest quality standards in the US.
Learn more about your unit Learn more technical information about your unit at www.cooperandhunter.us, where you can find submittals, leaflets, videos and all technical specifications of your unit. Step 1 On the website cooperandhunter.us, type in your unit model number into the search field and click enter.
Page 4
How to apply for the rebate program Almost all Cooper&Hunter equipment is eligible for the rebate program.Visit our website to see if the rebates apply to your location. Step 1 Go to cooperandhunter.us/rebates to add your zip code and select your outdoor unit to see if your unit qualifies for the rebate.
Page 5
INSTALLATION MANUAL SAFETY PRECAUTIONS INSTALLATION ELECTRICAL SPECIFICATIONS Read this manual Inside you’ll find many helpful hints on how to use and maintain your auxiliary heater properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your auxiliary heater.
SAFETY PRECAUTIONS Intended Use The following safety guidelines are intended to prevent unforeseen risks or damage from unsafe or incorrect operation of the appliance. Please check the packaging and appliance on arrival to make sure everything is intact to ensure safe operation. If you find any damage, please contact the retailer or dealer.
ELECTRICAL WARNINGS • The product must be properly grounded at the time of installation, or electrical shock may occur. • For all electrical work, follow all local and national wiring standards, regulations, and the Installation Manual. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal.
INSTALLATION NOTICE Installation must be performed by an licensed contractor. Please make necessary precaution when performing the installation operation. Accessories Preparations for Installation Before installation, please confirm the electric Name of Accessories Q‘ty(pc) Shape auxiliary heat module and supplied accessories are complete and free of any damage.
Page 9
Step 5 Electric Auxiliary Heat Module Remove 4 screws installation and Wiring Operation Remove screws Step 1 Open the upper cover. Remove screws Remove and Step 2 dispose the whole Use tools to cover remove the knock-out holes of upper cover. Step 6 turn the handles in the auxiliary Heater.
Page 10
Step 8 Step 11 Wire according to the wiring diagram. Turn the handles back and fix the Apply the wiring diagram on the inside screws. cover after wiring is completed for future reference and maintenance. Step 12 Install the front panel and remove the knockout basing the di erent heater model.
Page 11
Step 13 Fix foam gasket and install the silicone breaker cover with screws. Foam gasket Silicone breaker cover Step 14 After installing the electric auxiliary heat module, apply the circuit breaker label near the silicone breaker cover that was just applied. CAUTION Power o before service.
ELECTRICAL SPECIFICATIONS NOTICE Electric auxiliary heating wiring diagram packed with the accessories. If branch circuit wire lenght exceeds 100ft, consult the local code to determine maximum wire length. Use 2% voltage drop. After the electric heating wiring is connected, please confirm before power on: •...
Page 14
Electric auxiliary heating wiring diagram 3KW/5KW HEAT KIT 8KW/10KW HEAT KIT :THERMAL LINK :THERMAL LINK :THERMAL CUT-OUT, SELF-RESETTING :THERMAL CUT-OUT, SELF-RESETTING Aux-Heat TCO2 control signal TCO1 BLACK B L A C K 1 1 1 1 1 1 1 TO INDOOR UNIT RELAY2 HEATER2 DATA BOARD...
Technical Support Single & Multi-Zone Mini Splits • PTACs • Portables • TTWs • Light Commercial A/C Systems Limited Warranty provided by Cooper&Hunter (hereby referred to as C&H) covers specified products and parts, subject to the following details: Our warranty: C&H Limited Warranty applies only to products installed by a licensed HVAC technician.
Page 16
10. For resetting of power or the circuit breakers and replacement of other types of fuses, both internal and external. 11. For any damage caused by the use of dirty, recycled, or wrong type of refrigerants and lubricants. 12. For damage due to moisture, air, dust, sand, dirt, etc., that have been allowed into the system. 13.
Page 17
negotiations, representations, or promises, whether oral or written, of either party shall be deemed to have been merged herein. If any part of this warranty agreement shall be invalidated for any reason, such part shall be deleted, and certain legal rights and you may also have other rights, which vary from State to State. Therefore, some of these limitations or exclusions may not apply to you.