Hamersley MK2 Freestanding Troubleshooting (Continued) Read and follow these instructions carefully before installing and WARNING using this appliance SAVE THESE INSTRUCTIONS • A ue re with resulting damage may occur if the appliance is not installed, WARNING operated and maintained as per this booklet. •...
THIS APPLIANCE WEIGHS IN EXCESS OF 190 KILOGRAMS. EXTREME CARE SHOULD BE TAKEN WHEN HANDLING THE APPLIANCE. A.F. Gason Pty. Ltd. accepts no liability whatsoever for interpretation of AS/NZS 2918:2001 It is important you understand these installation instructions and minimum clearances to combustible materials before selecting a position for your Jindara Hamersley to ensure safe and correct installation is achieved.
Page 4
Hamersley MK2 Freestanding Installation (continued) • Installation Clearances Your Jindara Hamersley has been tested in accordance with AS/NZS 2918:2018 for standard and for corner installations. The below table and gures highlight the minimum allowable clearances for three di erent ue con gurations. For each con guration a minimum 24mm thick compressed board oor protector shall be used under the appliance per the below dimensions.
Hamersley MK2 Freestanding Installation (continued) Flue Installation The ue system must comply with Australian and New Zealand installation standards AS/NZS 2918:2001, and be installed to the ue manufacturer’s instructions. The performance of your Jindara Hamersley is highly reliant on an e ective ue system. In many cases poor start- up, dirty glass, down draft which causes smoking when door is open, and a reduction in heat output can all be related to the ue being too short, or incorrect installation.
Hamersley MK2 Freestanding Installation (continued) Flue and chimney requirements The flue pipe shall extend not less than 4.6m above the top of the floor protector. Note: Installation must be carried out by a licensed installer in accordance with AS/NZS 2918:2018. 3000mm More than 3000mm 6000mm...
Hamersley MK2 Freestanding Operating your Jindara woodheater DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITHOUT READING AND WARNING UNDERSTANDING THESE OPERATING INSTRUCTIONS THOROUGHLY. FAILURE TO OPERATE THIS APPLIANCE PROPERLY MAY CAUSE UNDUE DAMAGE TO THE APPLIANCE OR RESULT IN A FLUE FIRE. Read these instructions Starting your re Place a relighter or paper in the bottom of the rebox and place a large amount of small kindling on top.
Page 8
Hamersley MK2 Freestanding Operating your Jindara wood heater Operating your Eureka (continued) Cleaning your ue Carefully remove the ba e plate, cast iron plates, ash de ector and re bricks and put them to one side. Close the heater door. Obtain a 150mm ue brush from your local Jindara dealer and proceed up onto the roof.
Page 9
Hamersley MK2 Freestanding Troubleshooting • Noisy fan Turn the power o and remove the three pin plug from the power point. Remove the two screws that hold the front fan access panel. Remove the panel. Disconnect the wiring loom via the plastic joiner. Unscrew the two nuts which hold the fan in position and remove the fan. Clean any dust with a dry paint brush and vacuum the fan blades.
Page 10
Hamersley MK2 Freestanding Troubleshooting (continued) • Smoke entering the room from the rebox when the door is open may be caused by • Insu cient length of ue ( ue to be 4500mm minimum underneath the base of heater to underside of cowl) Increase height of ue •...