Ensemble Designs Avenue 7450 Manual

Hd protection switch data pack

Advertisement

Quick Links

Model 7450 HD Protection Switch
Model 7450
HD Protection Switch
Data Pack
Revision 1.2 SW v2.2.5
E
N S E M B L E
D
E
S
I
G
N
S
7450-1
www.ensembledesigns.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Avenue 7450 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ensemble Designs Avenue 7450

  • Page 1 Model 7450 HD Protection Switch Model 7450 HD Protection Switch Data Pack Revision 1.2 SW v2.2.5 N S E M B L E 7450-1 www.ensembledesigns.com...
  • Page 2: Table Of Contents

    Model 7450 HD Protection Switch Contents MODULE OVERVIEW SDI Signal Evaluation APPLICATIONS Auto-Switched Upconversion Application Fiber Feed Application 3RU and 1RU Backplane Diagrams Status and Alarm Cabling MODULE CONFIGURATION AND CONTROL 7450 Parameter Table Front Panel Controls and Indicators AVENUE PC REMOTE CONFIGURATION 7450 Avenue PC Menus Status Menu Con g Menu...
  • Page 3 Model 7450 HD Protection Switch Con g Menu Blk Detect Menu Aud Detect Menu Freeze Menu Pri Errors Menu Sec Errors Menu GPI Menu Inputs Menu Memory Menu TROUBLESHOOTING SOFTWARE UPDATES WARRANTY AND FACTORY SERVICE Warranty Factory Service SPECIFICATIONS 7450-3 www.ensembledesigns.com...
  • Page 4: Module Overview

    Model 7450 HD Protection Switch MODULE OVERVIEW The 7450 module is a fail-safe, bypass protection switch for critical digital paths for broadcast or satellite applications. When a fault is detected in the primary input, and the secondary input is veri ed as good, the switch will activate, causing the secondary input to be switched to the module’s output.
  • Page 5 Model 7450 HD Protection Switch Small Window which is approximately two thirds of the picture width and height, or Big Window which covers approximately 90% of the width and height. This allows a corner Bug to be either excluded or included in the detection process. Black detection is performed on a pixel-by-pixel basis within the selected window, with user selectable Detect Level and Blk Frac adjustments.
  • Page 6 Model 7450 HD Protection Switch Each of the signals is fed to identical detection circuits which evaluate multiple parameters and characteristics of the signal in order to arrive at a fault decision. Detection of TRS errors is done in a Receiver/Reclocker circuit which produces a reclocked serial output feeding a Deserializer circuit.
  • Page 7: Applications

    Model 7450 HD Protection Switch APPLICATIONS Auto-Switched Upconversion Application The diagram below shows a typical use for the 7450 module, where it is used to form a fully redundant, auto-switched conversion chain. The Primary input is backed up with a Secondary input from a video server.
  • Page 8: 3Ru And 1Ru Backplane Diagrams

    Model 7450 HD Protection Switch 3RU and 1RU Backplane Diagrams 7450 PS Connect the secondary (backup) Secondary In digital signal to the Secondary In BNC and loop the Sec Loop Out BNC to another destination in the Sec Loop Out facility if needed.
  • Page 9: Status And Alarm Cabling

    Model 7450 HD Protection Switch Status and Alarm Cabling In addition to full monitoring and access through the control system, the 7450 module provides contact closure status indications through the 15-pin D Control connector on the corresponding rear slot of the frame. These connections can drive an alarm system or other external monitoring devices, including LEDs.
  • Page 10: Module Configuration And Control

    Model 7450 HD Protection Switch MODULE CONFIGURATION AND CONTROL The con guration parameters for each Avenue module must be selected after installation. This can be done remotely using one of the Avenue remote control options or locally using the module front panel controls.
  • Page 11: 7450 Parameter Table

    Model 7450 HD Protection Switch 7450 Parameter Table CONTROL LOCAL REMOTE DEFAULT USER LEVEL Auto Reset Admin Reset Time 15 seconds 0 - 60 seconds 15 seconds Admin TRS Test Switch 1: Lenient Admin Lenient Strict Audio Detect Switch 3: Admin Black Detect Switch 4:...
  • Page 12 Model 7450 HD Protection Switch CONTROL LOCAL REMOTE DEFAULT USER LEVEL PRI GPI Mode Neg Edge Switch Neg Edge Switch Admin Neg Edge Switch Ext Fault Low Ext Inhibit Low Neg Edge Reg 1 Sec GPI Mode Neg Edge Switch Neg Edge Switch Admin Neg Edge Switch...
  • Page 13: Front Panel Controls And Indicators

    Model 7450 HD Protection Switch Front Panel Controls and Indicators Each front edge indicator and switch setting of the 7450 is shown in the diagram below: Auto green LED: Pri In OK green LED: ON when Auto is active. ON when Primary input passes OFF when Auto is turned o .
  • Page 14: Avenue Pc Remote Configuration

    Model 7450 HD Protection Switch AVENUE PC REMOTE CONFIGURATION The Avenue PC remote control status menus for the 7450 module are illustrated and explained below. Refer to the 7450 Parameter Table for a summary of available parameters that can be set remotely through the menus illustrated.
  • Page 15 Model 7450 HD Protection Switch • Auto Reset – set to On or O to determine if the switch will automatically switch back to the Primary after it recovers. • Reset Time – set the amount of time the Primary signal must be good before the auto reset switches back to Primary from Secondary.
  • Page 16: Con G Menu

    Model 7450 HD Protection Switch Con g Menu The Con g menu shown below allows you to con gure the various condition detectors: • TRS Test – enables the test for any Timing Reference Signal (TRS) errors. O sets the input for no TRS test, Lenient allows occasional TRS errors to be ignored (10 frames in a row), or Strict detects any TRS error as a fault.
  • Page 17: Blk Detect Menu

    Model 7450 HD Protection Switch Blk Detect Menu The Blk Detect menu shown below allows you to con gure the following black detector parameters: • Window – select Big or Small. Big examines nearly the entire raster. Small limits the test to a smaller portion of the raster (somewhat smaller than Safe Title limits).
  • Page 18: Aud Detect Menu

    Model 7450 HD Protection Switch Aud Detect Menu The Aud Detect menu shown below allows you to con gure the following audio parameters: • Audio Group – select which embedded audio group (Group 1 – 4) to detect. • Aud Thrsh –...
  • Page 19: Freeze Menu

    Model 7450 HD Protection Switch Freeze Menu The Freeze menu shown below allows you to con gure the following parameters for a video freeze condition: • Freeze Mode – set the freeze detection to Clean Source, Noisy Source, or O . •...
  • Page 20: Pri Errors Menu

    Model 7450 HD Protection Switch Pri Errors Menu The Pri Errors menu shown below displays the amount of time in seconds that each of the error conditions have been present after detection on the Primary as well as the number of times the Primary feed has switched to the Secondary feed (Sec Sw Cnt).
  • Page 21: Sec Errors Menu

    Model 7450 HD Protection Switch Sec Errors Menu The Sec Errors menu shown below displays the amount of time in seconds that each of the enabled error conditions have been present after detection on the Secondary as well as the number of times the Primary feed has switched to the Secondary feed (Sec Sw Cnt).
  • Page 22: Gpi Menu

    Model 7450 HD Protection Switch GPI Menu The 7450 can be set up to allow an external device to trigger a switch through the GPI interface. The GPI menu screen shown below allows con guration of the two external GPI inputs to the module. The Primary and Secondary GPI Modes can be set to one of the following: •...
  • Page 23: Inputs Menu

    Model 7450 HD Protection Switch Inputs Menu The Inputs menu displays the type of signal detected on the Primary and Secondary inputs. • Primary Input displays the HD SDI signal type detected on the Primary Input connector. • Secondary Input displays the HD SDI signal type detected on the Secondary Input connector.
  • Page 24: Memory Menu

    Model 7450 HD Protection Switch Memory Menu The Memory menu allows you to save and recall up to 5 di erent setups for the 7450 module as follows: • Click Save, then one of the ve memory registers Reg 1 – 5. The box will turn green. The entire module setup is now saved in the selected register.
  • Page 25: Avenue Touch Screen Remote Configuration

    Model 7450 HD Protection Switch AVENUE TOUCH SCREEN REMOTE CONFIGURATION The Avenue Touch Screen remote control status menus for this module are illustrated and explained below. Refer to the 7450 Parameter Table for a summary of available parameters that can be set remotely through the menus illustrated.
  • Page 26 Model 7450 HD Protection Switch • – lights red when the Secondary input is selected to the output. Press this switch control to select the Secondary as the output. • Auto Reset – set to On or O to determine if the switch will automatically switch back to the Primary after it recovers.
  • Page 27: Con G Menu

    Model 7450 HD Protection Switch Con g Menu The Con g menu shown below allows you to con gure the various condition detectors: • TRS Test – enables the test for any Timing Reference Signal (TRS) errors. O sets the input for no TRS test, Lenient allows occasional TRS errors to be ignored (10 frames in a row), or Strict detects any TRS error as a fault.
  • Page 28: Blk Detect Menu

    Model 7450 HD Protection Switch Blk Detect Menu The Blk Detect menu shown below allows you to con gure the following black detector parameters: • Window – select Big or Small. Big examines nearly the entire raster. Small limits the test to a smaller portion of the raster (somewhat smaller than Safe Title limits).
  • Page 29: Aud Detect Menu

    Model 7450 HD Protection Switch Aud Detect Menu The Aud Detect menu shown below allows you to con gure the following audio parameters: • Audio Group – select which embedded audio group (Group 1 – 4) to detect. • Aud Thrsh –...
  • Page 30: Freeze Menu

    Model 7450 HD Protection Switch Freeze Menu The Freeze menu shown below allows you to con gure the following parameters for a video freeze condition: • Freeze Mode – set the freeze detection to Clean Source, Noisy Source, or O . •...
  • Page 31: Pri Errors Menu

    Model 7450 HD Protection Switch Pri Errors Menu The Pri Errors menu shown below displays the amount of time in seconds that each of the error conditions have been present after detection on the Primary as well as the number of times the Primary feed has switched to the Secondary feed (Sec Sw Cnt).
  • Page 32: Sec Errors Menu

    Model 7450 HD Protection Switch Sec Errors Menu The Sec Errors menu shown below displays the amount of time in seconds that each of the enabled error conditions have been present after detection on the Secondary as well as the number of times the Primary feed has switched to the Secondary feed (Sec Sw Cnt).
  • Page 33: Gpi Menu

    Model 7450 HD Protection Switch GPI Menu The 7450 can be set up to allow an external device to trigger a switch through the GPI interface. The GPI menu screen shown below allows con guration of the two external GPI inputs to the module. The Primary and Secondary GPI Modes can be set to one of the following: •...
  • Page 34: Inputs Menu

    Model 7450 HD Protection Switch Inputs Menu The Inputs menu displays the type of signal detected on the Primary and Secondary inputs. • Primary Input displays the HD SDI signal type detected on the Primary Input connector. • Secondary Input displays the HD SDI signal type detected on the Secondary Input connector.
  • Page 35: Memory Menu

    Model 7450 HD Protection Switch Memory Menu The Memory menu allows you to save and recall up to 5 di erent setups for the 7450 module as follows: • Select Save, then one of the ve memory registers Reg 1 – 5. The box will turn green. The entire module setup is now saved in the selected register.
  • Page 36: Troubleshooting

    • Check cabling to input of the module. Please also refer to the technical support section of the Ensemble Designs web site for the latest information on your equipment at the URL below: http://www.ensembledesigns.com/support SOFTWARE UPDATES Software updates for each module can be downloaded remotely if the optional System Control module is installed.
  • Page 37: Warranty And Factory Service

    This product is covered by a ve year limited warranty. If you require service (under warranty or not), please contact Ensemble Designs and ask for customer service before you return this product. This will allow the service technician to provide any other suggestions for identifying the problem and recommend possible solutions.
  • Page 38: Specifications

    Model 7450 HD Protection Switch SPECIFICATIONS Serial Digital Input Number Signal Type HD Serial Digital 1.485 Gb/s SMPTE 274M, 292M or 296M Max Cable Length 100 Meters (Belden 1694A or equiv.) HD Standards Supported 1080i (SMPTE 274M -4, 5, 6) 50, 59.94 or 60 Hz 720p (SMPTE 296M -1, 2, 3) 59.94 or 60 Hz 1080p (SMPTE 274M -9, 10, 11) 23.98, 24, 25 Hz 1080sF (RP211 -14, 15, 16) 23.98, 24, 25 Hz...

Table of Contents