1. PURPOSE OF THE USER MANUAL The present User Manual has no contractual value whatsoever and under no circumstances may Echosens be held responsible on the basis of the information contained in the present manual. The present User Manual details, on the one hand, all of the information required for the implementation, use and maintenance of the FibroScan instrument and, on the other hand, the list of information displayed.
These manuals cannot be distributed, translated or reproduced, either in whole or in part, in any manner or in any form, without prior written consent from Echosens. Hence, the reproduction, adaptation or translation of the present manual without prior written consent is prohibited, within the limits provided by copyright law.
FibroScan. These results are then interpreted by the physician in charge. Under no circumstances, and even if Echosens had been notified, would Echosens be held responsible for the incorrect interpretation of these results;...
USER MANUAL FIBROSCAN 402 8. CLEANING, MAINTENANCE AND REPAIRS In the event of malfunction, only the staff of Echosens or its local representative is authorised to work on the FibroScan and its accessories. Any work performed by an unqualified person will terminate the guarantee.
Dry, if necessary, using a soft dry cloth. Examine the transducer and probe cable for any damage such as cracks, breakage, or liquid leakage. If any damage is observed, stop using the probe and contact Echosens or its local representative: service@echosens.com Precautions Do not submerge or soak the probe.
The standby pushbutton is on, Turn the machine off, then on again. but the software is not booting. In the event of a failure or malfunction, please contact Echosens or its local representative: service@echosens.com 8.4. CHANGING THE PRINTER ROLL To change the paper: Open the cover and remove the empty roll.
12.1. ELECTROMAGNETIC EMISSIONS The FibroScan 402 is designed for use in the electromagnetic environment defined below. FibroScan 402 customers or users must ensure that it is indeed used in such an environment. Emission test Compliance...
12.2. ELECTROMAGNETIC IMMUNITY (1) The FibroScan 402 is designed for use in the electromagnetic environment defined below. FibroScan 402 customers or users must ensure that it is indeed used in such an environment. Immunity IEC 60601 test Compliance...
Page 50
To assess the EM environment caused by fixed emitters, a site EM study must be conducted. If the strength of the fields measured at the location where the FibroScan 402 is used exceeds the above-mentioned compliance levels, correct operation of the FibroScan 402 must be checked. If any abnormal performance is observed, additional measurements may be necessary, e.g.
12.4. RECOMMENDED SEPARATION DISTANCES (between portable or mobile RF communication devices and the FibroScan 402) The FibroScan 402 is designed for use in an electromagnetic environment in which RF disturbance is controlled. FibroScan 402 customers or users may prevent interference by...