FMA spray control with ISOMatch User's manual Original instructions manual Edition 11.2019 Date of printing 11.2019 Language Software version from V 1.19 Document Number VN70051743-5...
Author's right and copyright are vested in the Kverneland Nieuw-Vennep B.V., The Netherlands. Making copies, acquisition in other media, translation and use of excerpts or portions of this manual without the express permission of Kverneland is prohibited. All rights reserved. The...
FMA operation in the tractor cabin Driving speed Control options Position of the slope correction Electrical / hydraulic remote control Height measurement of the spray boom ISOMatch for ISO communication Throughput quantity and spraying FMA menu structure explanation pressure Main menu Tank capacity...
Preface Preface Target group of this This manual is intended for fully qualified agrarians and other persons authorised to use this implement and other crop protection products in manual accordance with national legislation. Training for the agricultural sector and knowledge of assembly activities are required. Definition of the term The implement is understood to mean effective combination of an agricultural spray with the spray control and control box described in...
Preface Meaning of Various symbols are used to provide a clear understanding of the text. These are explained below: symbols • A dot is placed before lists. A triangle marks tasks you have to perform. An arrow refers to a different place in the text. In addition, we use pictograms to help you to easily find certain text sections.
Safety Safety Safety requirements Knowledge of the safety regulations forms the guiding principle for safe and trouble-free operation of the implement. Follow in this regard the instructions given in the user manual of your agricultural spray. most accidents can be prevented. By ignoring the safety instructions, you would be risking serious or fatal accidents.
Page 8
Safety Avoid contact with materials You could easily come into contact with materials when filling the machine. Always wear protective clothing, such as safety gloves, shoes, filter mask and goggles. Also read and adhere to the safety instructions of the material manufacturer. Contact with the materials may cause injury.
Page 9
Keep in good working condition Keep the terminal in good working condition. Use original parts Only use original parts from the Kverneland Group. Using other products can cause failure or lower safety. The validity of the guarantee is voided if non-original spare parts are used.
Page 10
Safety Checking cables Check the cables before connecting and replace damaged cables. Damaged cables can cause damage and failure on the terminal. Checking the temperature range Maintain the temperature range of the terminal in the gap. Higher or lower operating temperatures can cause failures in the terminal. What to do in case of technical failure If there is a technical failure ...
FMA spray control. Ease of operation most modern electronic control systems: • ISOBUS communication via tractor or ISOMatch terminal • iXclean, line for filling, dilution and cleaning system • iXclean Comfort, with electrically driven suction valve •...
Page 12
Getting familiar with the machine General The FMA spray computer ensures that the spray volume in litres per hectare always matches the desired value, irrespective of the driving speed and the working width at that stage. The computer continuously computes the requisite fluid flow (l/min) to be pumped to the nozzles based on the programmed spray volume (l/ ha), the current driving speed (km/h) and the active working width (m) at that stage.
Page 13
Getting familiar with the machine Changing during spraying The desired spray volume (desired value) can always be changed by the driver any time during the ride. It is also possible to adjust the spray volume manually at certain points in the field. Pressing the button can then return the operation to automatic mode, so that the programmed desired value is again controlled automatically.
Page 14
Manual setting for slope correction / steer to central position. The ERGODRIVE software, with associated hardware, is supplied to FMA users as • Back order for existing implements with FMA control with control • New machines with FMA + ISOMatch.
Page 15
Getting familiar with the machine ISOMatch Grip The ISOMatch Grip accessory is a control unit on which most of the implement functions used can be operated centrally with one handle. This is available in addition to the ISOBUS terminal. Handle control While working attention and visibility is often required to follow the work process.
GEOspread. automatic section control ISOMatch webshop Additional information and purchase of software licenses Go to the ISOMatch web-shop to view all possibilities for your www.isomatchshop.com machine. Here you will find a comprehensive description of all software and associated positioning potentials.
Page 17
Getting familiar with the machine FMA components on the Sprayer components: • sprayer ISOBUS connector • Central distributor box • Communication module • SHC switch cabinet (for >18 functions distributed over 2 boxes) • iXclean Comfort control box with tank level gauge (optional) •...
Here connected as part of the iXclean Pro electrical valve set (option) FMA operation in The FMA spraying control system with ISOMatch control box consists of the following components: the tractor cabin • ISOMatch (or ISO-tractor terminal) control box •...
If the tractor does not have an ISO communication bus, it can be added with the ISOMatch power cable set. The ISOMatch power forms the connection with your sprayer in case ISOMatch power cable set your tractor has no separate ISOBUS connection.
Starguide The remote electrical control does not have a separate main switch The system is switched off using the main switch on the ISOMatch or the Iso Tractor. For the correct connections, see the manual of the control box or...
Getting familiar with the machine Spray function The following spray functions are electrically operated on the top part of the remote control: Switch Function(s) Central switch for Spray on/off Similarly, the (optional) ERGODRIVE functions are activated Switch for pressure setting Switch section Right Switch section central Choice switch for serial and individual section switch mode...
Getting familiar with the machine Hydraulic functions he following spray functions are hydraulically operated on the bottom part of the remote control: Switch Function(s) Lifting/lowering spray boom Hydraulic slope correction independent slope correction, right HC: Vertical folding of the right hand boom package independent slope correction, left HC: Vertical folding of the left boom package Drawbar- resp.
Getting familiar with the machine ISOMatch for ISO communication ISOMatch as full ISO terminal Tractors with an extension to ISOBUS connection use a loose- standing ISO control box in addition to the electrical remote control. Many functions and programmes on one control box The divided screen has a flexible division to: •...
Page 24
Getting familiar with the machine ISOMatch Tellus GO Compact and complete ISOMatch Go, as a handy and more compact variant of the double- screen version, offers complete ISO control with all functions. Besides the smaller dimension with the single screen, the number of USB connections and the absence of Wlan/Wifi constitutes the biggest difference.
Page 25
Getting familiar with the machine Configuration screen With the configuration screen key, you directly reach the screen where you can modify the various settings of your ISOMatch or Tellus GO. Consult the user's manual of the control box or tractor for further information.
Page 26
Manuals screen Manuals tab The manuals screen can be opened with this tab. Manuals screen The operating manual of the IsoMatch and all other applications are given here. • You can go up and down through the list with the arrows •...
Page 27
Suppose you want to change the spray volume: Touch the set value of spray volume in the nozzle selection and spray volume screen. The keyboard pops up on the screen. ISOMatch keyboard Operation 1 screen with keyboard Current dosing: 150 l/ha Value to be modified The values chosen by you on the screen are shown at the top of the keyboard displayed.
Page 28
Getting familiar with the machine The change is saved when you press the OK button. Thereafter, you can choose a following value in order to change it. pull down menu Before choosing a given application, a menu of the value to be changed with various choices below one another may appear after the touch.
Getting familiar with the machine FMA menu structure The method and screen display for the use of the ISOMatch control are given in this instruction. explanation The operating system (the software) of the control system has 4 menus: • Main menu with spray functions that you need during spraying, •...
Page 30
Getting familiar with the machine Menu structure...
The function lock applies to: • driving with spray boom folded in with driving speeds above 15 km/ h (Red lock) This allows you to continue to use the ISOMatch during road transport when using cameras for peripheral vision. •...
Page 33
Getting familiar with the machine Icon colours in the main Spraying cones and spray boom are coloured differently after functions are switched on or off: screen Green Boom Guide icon: automatic Boom Guide, boom height system icon • Green Boom Guide icon: automatic mode •...
Getting familiar with the machine Settings and service menu With the buttons on the right of the main screen, you can open a variety of menus: By pressing the key switch, you reach the first screen of the settings and service menu. In the first screen of the settings and service menu, you must enter some necessary data for correct implement operation before use.
Page 35
Getting familiar with the machine Nozzle selection and spray volume screen By pressing the spraying nozzle key, you come from the main screen to the nozzle selection and spray volume screen. In this screen, you enter the desired value for: •...
Page 36
Getting familiar with the machine Functions with iXclean Pro FMA with iXclean Pro for mounted and trailed implement The functions Fill system lines and Rinse system lines can, however, Active function only be operated or controlled via the valve management. Injector agitator Fill system lines Rinse system lines...
Page 37
Getting familiar with the machine iXtra screen with iXclean Pro functions The screen shows the 4 iXclean Pro functions for the iXtra front iXtra cleaning programme active function tank Injector agitator Cleaning the tank Empty the tank iXclean Pro function ...
Page 38
Getting familiar with the machine Operating the functions on the ISOMatch Choose the valve management screen. Choose the desired function with the “Arrows” keys. The desired function is marked with a point. Activate the selected function. In case of the iXclean Pro (optional) the valves A, B and C are now...
Page 39
The “Terminal Settings” screen You can set the terminal use in this screen. You can place the machine screen below or above in the two ISOMatch screens with this key By pressing the scroll keys, you reach the next screen of this menu.
Getting familiar with the machine Execution variants The FMA execution variants are described hereafter. FMA in standard version By using the standard FMA the Agitator valve • Main valve “Spray On/Off” • Pressure control valve • valve of the return flow agitator •...
Getting familiar with the machine iXclean Comfort Additional control box with electric tank level gauge on the implement Automatic main tank The iXclean Comfort is an extension of the control centre of your filling system (optional) sprayer. The electric tank level measurement and (optional) electric suction valve measurement are controlled with this function.
Getting familiar with the machine iXclean Comfort control The operational components are explained in the overview that follows. panel Monitor Increase / scroll back button Confirmation button Home key Decrease / scroll button Keyboard The iXclean Comfort has 4 keys and a monitor: Home key Increase / scroll back button Start, selection and confirmation button...
Getting familiar with the machine iXclean Comfort work While working with the iXclean Comfort, you get information from the various screens on the display. and setup screens Main screen After starting and unlocking the spray control, the main screen appears. Main screen with an electric suction valve Tank content is shown Main screen with an electric suction valve...
Getting familiar with the machine Instruction screen with a If the iXclean Comfort does not detect an electric suction valve you will be given instructions to manually set the suction valve. manual suction valve Clean water tank iXter "Clean water tank" valve position NOTE The valve positions for Ixter and trailed sprayers are different! Clean water tank Trailed sprayer “Clean Water Tank”...
Page 45
Getting familiar with the machine iXclean Comfort operation You can operate the following functions with the iXclean Comfort: Function Display Description of the function Valve A is set to position suction connection or the unused setting, the connection to the tank is interrupted; the suction filter can be Clean Filter removed for cleaning without spraying agent escaping from the tank.
Getting familiar with the machine iXclean Pro electric With the optional iXclean Pro module, an electric valve set, most of the functions are operated on the FMA control box from the tractor cabin. valve set (optional) With FMA with optional iXclean Pro, the following valves are also iXclean Pro box switched electrically: •...
Page 47
Getting familiar with the machine Cleaning the iXter with iXtra Front tank with another spraying agent front tank Both cleaning programmes run independently of each other. As a result, the front tank with a second agent can be cleaned independently without contact between the spraying agents. Cleaning iXtra Pro Process progress indicator bar The front tank iXcleanPro programme is active:...
Page 48
Getting familiar with the machine Cleaning iXter iXclean for trailed and mounted implements The iXclean Pro cleaning programme is carried out for the iXter. This Process progress indicator bar takes place for mounted and trailed implements at the same time. Spraying out rinsing liquid During the programme while driving on the worked field the rinsing liquid is discharged twice through various automatic section...
Getting familiar with the machine iXclean Pro control box The iXclean Pro control box has a display in which the implemented function is given in text. Monitor Increase / scroll back button Home key F0000 M0000 Confirmation button Spray Off Decrease / scroll button Keyboard The iXclean Pro has 4 keys and a monitor:...
Getting familiar with the machine iXclean Pro work and While working with the iXclean Pro, you get to browse through the settings screens various function screens in the display of the control box on the valve plate of the sprayer. Extra functions with front tank With the mounted implement, iXter, including the iXtra Pro front tank, the front tank functions are also shown once selected in the tank...
Page 51
Getting familiar with the machine Page through the work menu by pressing the scroll key. The first function, "Front tank filling" is shown on screen. F0000 M0000 Front tank filling with the pump and suction hose of the iXter Pump Fill Front Predefined capacity is filled (topped up).
Page 52
Getting familiar with the machine F0000 M0000 Agent is pushed from the spray line by pumping from the clean Rinse System water tank If there is an interruption in spraying, the spray line system is rinsed with clean water right up to the nozzles. The spraying agent in the spray line system can thus be spread in a targeted manner.
Page 53
Getting familiar with the machine F0000 M0000 Draining residual water or antifreeze through iXter drain point suction valve Emptying After removing the cap (L), under the suction valve, you can empty the NLY I iXter main tank into a trough if it contains residual water or antifreeze. The suction valve disconnects the tank before cleaning of the F0000 M0000...
Page 54
Getting familiar with the machine System settings menu Personal settings and default values can be adjusted in this menu. The system settings menu is opened from the main screen. Press and hold both the home and OK key to open the setup menu. The first settings screen is displayed.
Page 55
Getting familiar with the machine No setup option Max Water Level No setup option Water Fill Level Setting maximum spray tank capacity Max Main Level Setting the highest filling level Main Fill Level Setting the volume of the alarm signal Buzzer Volume Switching alarm signal on or off Warning Buzzer...
An optional spray boom height sensor is fitted on these implements. In order to achieve the correct connection of your spraying activity, you must • make adjustments on the “Operation 2” screen. See »ISOMatch settings when using ERGODRIVE« on page...
Getting familiar with the machine Technical specifications IsoMatch Tellus GO Operating voltage (Vdc) 8-28 8-28 Fuse (A) IM power / ITH supply cable Ambient temperature ( C) during work -10 to +50 save -20 to +60 Screen Double touch screen...
Upgrading to ISO-tractor A non-ISO tractor needs to be adapted to the ISOBUS standard. An ISOMatch or Tellus GO control box is then used as a tractor terminal. An ISOMatch power cable set completes the ISOBUS upgrade of your tractor. The ISOMatch and Tellus GO upgrade are compatible as a full ISO communication system.
Before first use Mounting instructions Before the machine can be used, various parts and supplied accessories must be unpacked and assembled. Use the assembly instructions in the instruction book of the control box and the components list to find the parts and their place in the implement.
Connect the box to the ISO system of your tractor by means of the ISO-cabin connection cable. Tellus GO ISOMatch, Tellus GO terminal If you use the control box with a tractor equipped with the ISOBUS communication system, you can connect it with the supplied 7-pin CAN cable to a standard tractor CAN connection.
Page 61
Before first use Conversion to ISO tractor Adapting non-ISO tractors with ISOMatch power cable set With the ISOMatch power cable set, you can equip any tractor type with ISOMatch power cable with a full ISOBUS communication system. You now have: •...
Page 62
In tractors with the ISOBUS communication system, the tractor takes care of the signal. Tractors with an ISOMatch can receive the signal from the tractor electronics, tractor radar or wheel sensor. If you want to use the driving speed signal of the GPS receiver on the tractor, you should connect the plug behind the control box.
Page 63
Before first use Wheel ring A greater number of pulses per wheel rotation provides a more accurate speed measurement. 250 pulses per 100 metres is the Wheel ring minimum required value. If you do not attain the desired number of pulses with the wheel sensor against a part of the tractor, two types of wheel rings can be supplied: •...
A “start-up wizard” appears on the ISOMatch screen during the first start-up. This only happens at the first start-up! Start the ISOMatch with the main switch on the upper left in the red extension. The "Startup wizard" appears now ...
Page 65
The first screen is “Operation 1” Here you can change the values per line by touching these on the screen. See also section »Entering and modifying values (ISOMatch)« on page 26. iXtra Pro front tank 3-position switch electric pump...
Page 66
The sensor is connected on the SHC box on the spray. • Starguide The speed signal originates from a Starguide GPS system which is already present on the tractor and is linked to the ISOMatch via the RS232. • J1939...
The alarm function “Drop Size Too Large / Too Small” is disabled here. This means that the alarms no longer appear during the spraying. Drop size too large/too small alarms Warning function activated. Warning function disabled. See also section »Entering and modifying values (ISOMatch)« on page 26.
system settings System alarms If a system alarm appears on the control box screen, you must stop immediately. The implement cannot perform the requested function adequately because the power supply is insufficient or the control is not responding correctly. Fix the failure before working any further. The supply voltage of the control system has gone below the set alarm level.
Page 69
ISOMatch settings when using ERGODRIVE The “Operation 2” screen In this screen you can adjust the system settings of your ISOMatch when using • Spray nozzle height from the ground during spraying. • Lifting height of spray boom during coverage of the headland.
Page 70
system settings Spray nozzle and lifting height The ERGODRIVE controls, at the beginning of each new work sequence, the spray boom according to the set nozzle height. You should adjust this value per spraying to the chosen nozzle and crop height.
Page 71
Use the measurement on your own control unit. Enter this base turn length. Here 9.25 metres. The ERGODRIVE will measure the traversed path where the spraying must start. See also section »Entering and modifying values (ISOMatch)« on page 26.
Page 72
Where it is necessary to drive on bends in a small fields, it is possible to disable the ERGODRIVE, only for this function. This is done in the "Operation 2" screen. See also paragraph »Entering and modifying values (ISOMatch)« on page 26 or »FMA menu structure explanation« on page 29. Headland curve assist The headland curve assist functionality (optional for the flatland middle part).
Page 73
system settings Boom guide use on The Ergodrive system interrupts the boom guide function (optional) while turning on the headland. headlands If the spray boom has too much movement while turning, the boom guide (accessory) can also be switched on on the headland This is done in a pull-down menu: ...
Page 74
system settings Calibration of the sensors “Calibration” screen The “Calibration” screen shows the default values of the various sensors. Depending on the version of your implement, this screen shows the: • Driving speed sensor, pulses per 100 metres • Flowsensor screens, pls/lt. en lt./min •...
Page 75
Check the settings in the control system with regards to driving speed measurement and change as required, See paragraph »Choice of ISOMatch driving speed signal« on page 66. Check the inflation pressure and ensure that it is at the required levels.
Page 76
Adjusting the filter for the driving speed and pto shaft signal You can change these settings in the tractor ECU screen of the Tractor ECU menu button ISOBUS tools screen. See the Tractor ECU manual in your ISOMatch for this. ISOMatch manuals...
Page 77
The stated value in l/min comes to only 95% of the measured value. 617.5 Reduce the number of impulses by 5%. See also section »Entering and modifying values (ISOMatch)« on page 26. • The stated value comes to 105% of the measured value.
Page 78
system settings Direct input of the application The paragraph »Method for "gauging"« on page 77, indicates a yield rate in litres per minute. Select the input screen l/min Enter this value directly via the second input screen, l/min. The system uses this value in its calculations to determine your desired application rate in litres per hectare.
Page 79
If the distance from the nozzles to the plants is to be shown on the display, the crop height should also be taken into account for the correction value. See also section »Entering and modifying values (ISOMatch)« on page 26. Calibration of the spray For a correct height measurement, you (or the dealer) must enter the nozzle height with the arms of the parallelogram fully horizontal.
Page 80
system settings Press the "scroll" key to go to the next screen This is followed by the fourth screen of the settings and service menu; • “Section Width” for a trailed- • “Calibration Steer” for the trailed implement 0 setting for iXclean spray Optimizing the iXclean cleaning programme If the tank level gauge during the use of the iXclean Pro system and front tank level gauges...
Page 81
system settings Calibrating the control In this screen the control sensors are calibrated and the working of the control mechanism can be adjusted. system Calibrating the centre position of By calibrating the central position of the control, the drawbar/ steering the steering - /drawbar control control system automatically functions correctly.
Page 82
system settings Press the right input field ”LIMIT” to define the maximum steering angle. The control unit emits 2 short beeps. Check the set maximum steering angle by turning the drawbar/ shaft to the maximum once to the left and once to the right. The tyres of the sprayer must not touch the tank in either case.
Page 83
system settings Damping of the steering reaction for driving straight In order not to let the control system react to the smallest changes when driving straight, it is possible to give the sensor a small "dead angle". In this range around the centre position, no steering signal shall go to the controls.
Page 84
system settings Delay in steering control If the sprayer is executed with an automatic stub steering, a path- related delay can be programmed. This can help prevent the stub- shaft from steering out directly on a steering movement of the tractor and the wheels being steering outside the track of the tractor.
Page 85
Border nozzle counts as extra working width. • The border nozzle falls within the working width. See also paragraph »Entering and modifying values (ISOMatch)« on page 26 or »FMA menu structure explanation« on page 29. • If you let both border nozzles spray together, you will gain 0.50 metres.
system settings Menu behind pin code The screens after the PIN-code screen show the factory settings. You Input screen of pin code can browse through these screens but cannot change the settings. Diagnosis menu You can reach the diagnosis menu from any screen of the settings and service menu by pressing the lens key.
system settings Set ISOBUS communication The implement can be driven by an external signal, for instance originating from a GPS receiver, nitrogen sensor or memory card. To assign a controlling function to the external signal, it must be received in the 'Task Controller' screen. Setting communication with Acceptance of an external signal and the correct form of communication must be checked and adjusted as required.
Page 88
Purchase the software licence in good time! You need to purchase the licence via the ISOMatch webshop in good time in order to be able to continue working without disturbance after the free time of use has expired.
Page 89
system settings Setting implement data The position of the signal receiver and the place where the implement works effectively are mostly different. Distance to work pattern on the To allow the implement to operate correctly or stop in the right place, ground you must run the following settings: ...
Page 90
system settings • Drawn implement Drawn implement Option button In this screen, you can run the following settings: Selector for drawn implement • Offset connecting point in relation to the tractor track (Ai) • Distance from signal receiver to hard wheel axle (Ci) •...
system settings Starting up and setting The system settings are necessary for the good operation of the iXclean Comfort control system. It has a basic factory setting on all the iXclean Comfort adjustable parameters. Most of the parameters can be changed individually by the user.
Page 92
system settings Alarm volume screen The volume level for the alarm signal is adjusted in this screen. Alarm volume Press the select button to display the current value. Current settings for the alarm volume Increase or decrease the volume levels given with each alarm. The factory setting is 95.
Page 93
system settings Fill step size screen Step sizes with which the number of litres are increased or decreased when setting the filling level are shown on this screen. Fill step Increase or decrease the step sizes for sounding the alarm when setting the filling level.
system settings Language selection The language selection with which you work is shown in this screen. screen Language options are: • English, Language • French, • German • and Dutch. Make your selection with the up or down buttons. The selected language is displayed.
Page 95
system settings Check for filling higher than nominal Check that the float stays clear of the top of the tank! (Ikarus S) With the Ikarus S the float can touch the top. Open the calibration screen from the main screen ...
system settings Interrupting calibration and Press this key to stop the procedure during calibration keeping old data and switch the main switch and the control box off. After 5 seconds switch the control box on again. You can continue working with the data obtained prior to the interrupted calibration.
system settings Exiting the settings After all the settings have been adjusted you will exit the settings menu and return to the main screen. menu Press the Home button to go straight to the main screen. Press the select button to close the settings menu. exit Exit menu screen.
system settings Starting up and setting The system settings are necessary for the good operation of the iXclean Pro control system. It has a basic factory setting on all the iXclean Pro adjustable parameters. Most of the parameters can be changed individually by the user.
Page 99
system settings Pin Authoris. Calibration menu behind a PIN code Your dealer can adjust any settings here Language selection menu. Language Here you can choose the language in which the function texts will be Dutch, German, English, French, Czech, Danish, shown on the display: Spanish, Hungarian, Italian, Norwegian and Swedish After confirming the question "Are you sure?", all settings are...
Page 100
system settings Max Main Level Setting maximum spray tank capacity Setting the highest filling level Main Fill Level Buzzer Volume Setting the volume of the alarm signal Switching alarm signal on or off Warning Buzzer Exiting the settings After all the settings have been adjusted you will exit the settings menu and return to the main screen.
Each buttons on the ISOMatch Grip can control one or more functions that are defined during the factory settings. See the user manual of the ISOMatch Grip for layout of the functions via the buttons. Function icons The functions assigned to the buttons in the ISOMatch Grip settings menu are indicated with an icon.
Page 102
Central section on / off Central position Return slope correction to central slope correction position Change the functions under the push-buttons to the required layout, if necessary. Follow the user manual of the ISOMatch Grip in this regard.
Connecting to the tractor Secure the operating elements Connecting to the tractor Ensure that parts such as ropes, hoses, etc., for remote actuation of devices such as cylinders, are positioned in a way they never inadvert- ently release nor block them. Unintentional movements can lead to serious injury.
The function lock applies to: • driving with spray boom folded in at speeds above 15 km/h. This allows you to continue to use the ISOMatch during road transport when using cameras for peripheral vision. • while starting up the FMA.
Page 105
Activities before spraying Entering Spray details If all system settings are done, you can now start entering the spray details. Using the spray nozzle key, go to the screen for nozzle selection and spray volume. Nozzle selection and spray In this screen, you enter •...
Page 106
Activities before spraying Setting Simulation driving Simulation speed replaces the measured driving speed speed The simulation unit is automatically used as replacement value, if the central spray switch is connected and no speed signal is present. This happens if Simulation driving speed •...
Page 107
Activities before spraying Make nozzle selection To be able to use the alert function relating to the pressure range, the nozzle used must be selected from the list of the 5 pre-selected jet nozzles (nozzles 1 - 5). This choice is made by choosing the nozzle symbol with the corresponding number.
Page 108
Activities before spraying Unknown nozzle If a nozzle is used for spraying that is not in the nozzles list of the FMA (unknown nozzle), the NOZZLE position must be selected instead of a nozzle type from the nozzles list. In the example screen it is nozzle selection 4 and 5.
Page 109
Activities before spraying Setting drop size You can now enter the desired drop size. The user shall accordingly be warned if the desired drop size can no longer be achieved. Setting drop size Press the drop size setting area ...
Page 110
Activities before spraying Correcting the measured Throughput for liquid fertiliser throughput quantity The flow meter is calibrated with water before use. When drawing out liquid fertiliser, on the other hand, the higher viscosity causes a Correction to the flow different number of impulses per litre. It is easily possible to change the measurement of the throughput quantity in entry field C% without performing the calibration of the flow meter again.
Activities before spraying Filling Avoid contact with materials You could easily come into contact with materials when filling the machine. Always wear protective clothing, such as safety gloves, shoes, filter mask and goggles. Also read and adhere to the safety instructions of the material manufacturer.
Page 112
Press the stop key to stop the filling. The value is incorporated in the main screen after termination of the filling. Operation via the ISOMatch Starting position: • Main screen •...
Page 113
Activities before spraying • Filling with spray pump through suction hose and intensive mixing Function symbol Nominal tank volume Choose the function Fill with Spray Pump. At top right in the screen, the nominal capacity of the spray tank appears as standard filling quantity.
Page 114
Activities before spraying AUTO Start filling Start the filling by using this key The filling process is activated: With iXclean Pro (optional) the valves A and B are now automatically AUTO set to the "Fill with Pump" position on the control centre of the spray. iXclean Pro or Comfort control Operation via the iXclean Pro control box on the valve plate of your implement:...
Page 115
Operation via the iXclean Pro control box on the valve plate of your implement: Starting position: See »Operation via the ISOMatch« on page 112. M0627 Fill + Agitation Select ”Filling and Agitation” or “Filling with pump” on the iXclean...
Page 116
Activities before spraying Resume filling Resume filling with the OK key Ltr = 3800/2100 When the preset percentage (75%) of the fill quantity is reached the fill alarm is sounded. Continuation is also shown in this screen. Lt = 3800/2800 As soon as the tank is filled, the new tank capacity is displayed M2800 The valves are automatically to the “spray off”...
Page 117
Activities before spraying With the iXclean Comfort The iXclean Comfort controls and monitors the process of filling the sprayer tank with a suction hose and sprayer pump. (option) Starting position: • Main screen, • central Spray switch on "OFF". • Suction hose connected in the correct position.
Page 118
Activities before spraying Manual fill stop When the preset filling quantity has been reached the iXclean Comfort shows the full bar and filling quantity. 1500 Lt. The full hopper and fill quantity. NOTE Filling continues until the suction valve is closed! Valve position The instruction screen with the new valve position is then shown.
Page 119
Activities before spraying Filling with the electric suction valve of the iXclean Comfort Select the screen “Filling the spray tank with a suction hose” with the scroll button 1500 Lt. Open the screen with the select button. The screen that displays the fill quantity appears. ...
Page 120
Activities before spraying Fill alarm • When the preset percentage (75%) of the fill quantity is reached the fill alarm is sounded. • Continuation is also shown in this screen. 1125 Lt. The preset percentage (75%) of the fill quantity has been reached.
Activities before spraying AUTO Filling interrupted Press the "Stop"-button to interrupt the filling process at any moment. With iXclean Pro the valves are at the same time automatically set to AUTO the “Spray OFF” position. Set with the standard version valves A and B on "Spray OFF": MAN.
Activities before spraying Agitation with injector After filling and rinsing in the crop protection products, the injector agitator (optional) brings about very strong circulation in the spraying agitator agent. This mixes the spraying agent very quickly and thoroughly. Switch on Injector agitator Initial position The central switch Spray is on status "OFF".
Page 123
The external system and the control system of your implement with ISOMatch control box communicates via a serial port with a so-called RS232 connection. This connection is located at the back or at the bottom of the control box. The occupation of pins in the 9 point RS232 plug and the settings required are given in ...
• the electric control system of the implement. * The ISOMatch may remain on if you wish to continue using the ISOMatch Eye camera for peripheral vision. See paragraph »Function lock during road transport« on page 125. Check the weight distribution between front and rear axles.
15 km/h with spray boom folded in. Automatic function lock above 15 km/h If you keep the ISOMatch switched on in order to use the Eye camera during road transport for peripheral vision, the other functions are locked above a driving speed of 15 km/h.
Driving on the road Before taking to Observe the permissible and safe height with regard to • the road prescribed maximum height for vehicles in the road traffic regulations, • high-voltage cables or other cables over the road, • anticipated maximum headroom. Pay close attention to these aspects to prevent dangerous situations that could lead to major material damage and possibly to serious physical injury.
Use in the field Follow all safety recommendations given in your implement Use in the field manual Friction between moving parts: Be careful of moving parts jamming while carrying out adjustment activities. You could accidentally touch control levers and cause the machine to move.
Use in the field Adjusting the Before you can make the first pass, you must make adjustments or check settings in the field to: machine • Desired spray volume • Nozzle selection and drop size • Nozzle height above ground or crop •...
Use in the field Tank selection with While spraying with the iXter with iXtra Pro front tank, you have the following options: iXter/iXtra combination • to empty the combination completely when both tanks have been selected • to empty only the main tank (iXter) •...
Use in the field Site registration The control system can register and save a few details of every field. Total application size of a field The following details can be saved for 40 sites: • The time and date on which the relevant field was registered for the first time.
Use in the field Spray On/Off Central switch for Spray on/off When operating the central switch, depending on the version of the controller, the main valve or all section valves are opened or closed simultaneously. (switch up = “Spray On” The position of the switch is displayed in the main screen with a blue triangle in the spray tank With GEOCONTROL, all spray sections can be closed when passing...
Use in the field Fill system lines The Fill system lines function can be used to fill up the spray line system up to the nozzles with spraying agent at the beginning of the spraying activities. This means that the spraying agent is directly at the nozzles at the beginning of the spraying and you can drive off directly.
Page 133
Use in the field The quantity of liquid required for the filling is shown in the main screen of your terminal at the left next to the tank. Set the central Spray switch to “ON”. (switch up = “Spray On”) This starts the filling process;...
Use in the field Spray function The spray functions are electrically operated with a remote on the control unit of the FMA. with ERGODRIVE Central switch (up) "Spray" On When engaging the central switch the ERGODRIVE successively • Lowers the spray boom •...
Use in the field Actual spray volume l/ At top right in the display the actual spray volume is shown in l/ha. The desired value, which you have entered, is shown at bottom left. If the FMA is working in auto mode, the desired and the actual values must be practically the same.
Use in the field Position of the slope correction At left below, in the main screen, the position of the hydraulic slope correction is shown with a pointer (if the spray boom is made with the relevant sensor). This indication facilitates, for example, finding the central position for the folding (black triangle = central position).
Page 137
Use in the field Nozzle height In the basic setting the working height is the distance from the spray boom (or nozzles) to the ground. Nozzle height to crop Since the working height is not measured directly, it can differ from the actual value, depending on the tyres and in-ground depth of the wheels.
Use in the field Using the boom guide when In default position, the ErgoDrive system switches off the boom guide when turning on the headland. turning on the headland If the spray boom has too much movement while turning, the boom guide can also be switched on on the headland.
Use in the field Pressure control Switch for pressure setting In the manual mode the spraying pressure is adjusted (+ or -) if the switch is depressed. The spraying pressure (bar) can thus be changed manually. The current spraying pressure can be read off on the manometer on the implement.
Use in the field Alarms During working, it may not be possible to perform the spraying in the set manner for various causes. The user is informed by the warning function that such deviations have arisen. Flow quantity alarm If the throughput velocity is too low, lower than 10 l/min, the flow meter can no longer meter correctly.
Use in the field Control system alarm Auto Steer The automatic control system is blocked, the spray boom is still folded or there is a sensor failure. Tank alarm If the remaining quantity in the tank falls below a certain value, which can be programmed on the "Operation 1"...
Use in the field Engaging sections Spray cone symbols It can be seen from the spraying cone symbols in the display which section widths are engaged or disengaged and whether the central switch for Spray is "ON" or "OFF". Every bar above 1 or several spraying cones represents a section.
Use in the field Switching when using For spraying with the task controller, the switch section can be used to switch off sections. the task controller The task controller does not open the closed sections. Closed section by switch Working width Direct below the spray on the display in the main screen is shown the active working width.
Use in the field Border nozzle Switch for border nozzle These two switches can be used for switching border nozzles. There are two options: • Border nozzle for exact field border spraying: In this case, the switching is done between the extreme nozzle and border nozzle (with smaller spray angle towards outside).
The Dilute function can also be operated on versions with iXclean Pro NDICATION by using the iXclean Pro box on the spray. see paragraph »iXclean Comfort operation« on page 45 or »iXclean Pro work and settings screens« on page 50. Operation via the ISOMatch Starting position: • Main screen, •...
Page 146
Use in the field MAN. Set valves A and B on the “Dilute” position: • Valve A on pos 2 (clean water tank) • and valve B on position 2 (Spray/agitate) • Valves D and E must be closed •...
Use in the field Open the function screen The correct valve position is shown on screen. Set valve A to the position as shown in the iXclean Comfort screen. Clean water tank Clean water tank valve position with the iXter NOTE The valve positions for iXter and the trailed sprayers are different! Clean water tank...
• and valve B on Pos 2 (Spray/agitate). See the chart “Functions and Valve Positions” in the manual of your sprayer. Operation via the ISOMatch Choose the screen “Valve management” from the main screen. Rinse system lines Choose the Rinse system lines function.
Page 149
AUTO Use in the field At the same time, the valves A and B are automatically set to the AUTO “Rinse system lines” position with iXclean Pro. With iXclean Pro box On the sprayer's iXclean Pro control box the function “Rinse system line”...
Page 150
Use in the field MAN. In case of the standard version, set all valves on the sprayer again AUTO on position "Spray OFF": • valve A on pos 1 (main tank) • and valve B on Pos 2 (Spray/agitate). ...
Use in the field Changing spraying Clean when treating other cultures It is essential to properly clean the entire sprayer on the inside after agents using different cultures as the toleration of the substances used differs greatly from one another. ...
Page 152
Use in the field Automatic cleaning of the The cleaning programme equipped with iXclean Pro, offers optimal system cleaning with the minimum use of clean water. spraying system (iXclean All aspects of cleaning are optimally programmed with regard to Pro) duration, water use and sequence.
Page 153
Use in the field Check the tank Always clean the tank which was last used first for the iXter/iXtra combination. selection before Do this on the field just tilled cleaning Check if the tank just used is still active: ...
Page 154
Use in the field Discharging rinse water While cleaning the front tank, the rinsing water is discharged thrice over the field. After this, the cleaning stops and you return to the valves management screen of the front tank. Set the main switch to “Spray off” After this, the iXclean Pro programme for the mounted and trailed sprayer is chosen if both tanks are used for spraying with the same agent.
Page 155
Use in the field Select from the main screen the “Valves management” screen for the iXter, Ikarus or iXtrack sprayers. Use the arrow keys to select the iXclean Pro cleaning function The red marking is at the bottom check box. ...
Page 156
Use in the field Discharging rinse water At various points, rinsing fluid is alternately discharged by various section combinations. Finally, the last rinse water is discharged by the middle section. Set the main switch to “Spray off” This sets all valves on “Spray Off”.
Open valve C for tank cleaning. See the chart “Functions and Valve Positions” in the manual of your sprayer. Operation via the ISOMatch Choose the screen “Valve management” from the main screen. AUTO Choose the Clean Tank function.
Page 158
Use in the field Clean water volume for tank The tank cleaning function stops automatically after a reduction from the clean water tank programmed in the iXclean Comfort box. This is cleaning dependent on the remaining quantity in the base unit. ...
Page 159
Use in the field Tank cleaning with iXclean If your implement is fitted with the iXclean Comfort and an electric Comfort and electric suction suction valve, the suction valve will be controlled automatically. valve Scroll with the scroll buttons from the main screen to the Intake from clean water tank screen Intake from clean water tank screen ...
Use in the field Checking and/or cleaning The suction filter could get dirty during repeated filling from surface water. The suction filter of your implement can be checked or cleaned the suction filter without any loss of spraying agent. Starting position: •...
Page 161
Use in the field iXclean Comfort Clean filter start screen Open the screen with the select button. The electric suction valve closes the connection between the filter and spray tank and screen moves to the setting where you can open the filter.
Use in the field Assemble the filter. Stop the function once the cleaned filter has been mounted. Set valve A back to its original position. Stopping work Directly after working with the implement, it is important that you perform the following actions before leaving: ...
Storing the machine Avoid contact with spraying agents Storing the machine It is easy to come into contact with the materials when putting away the machine. Always wear protective clothing, such as safety gloves, shoes and goggles. Also read and adhere to the safety instructions of the material manufacturer.
Page 164
Storing the machine With the electric suction valve of the iXclean Comfort Press the Home button to go to the main screen. The electric suction valve is driven from the spray tank in the intake position. Main screen with tank content Tank content can be seen while pumping back.
Page 165
Disconnect the back flow hose. Close the back pump connection off with the cap. System cleaning via ISOMatch If the remaining liquid fertiliser (AHL) is pumped back, you need to clean the spray tank, pump and valves. You need the cleaning programme "clean system"...
Storing the machine Drain the residual liquid After the sprayer has been cleaned and brought out to the parcel, the residual liquid can be drained, collected in a bucket and distributed (iXter B via suction valve) over the field. • The iXter can do this via the suction valve •...
Page 167
Storing the machine With the electric suction valve of If the iXter B sprayer is fitted with an electric suction valve, it will be the iXclean Comfort controlled automatically. Scroll with the scroll buttons from the main screen to the Drain screen.
Page 168
Storing the machine With manual suction valve The valve position needed for the draining of the spray tank is displayed on the iXclean Comfort screen. (iXter B) Scroll with the scroll buttons from the main screen to the Drain screen.
Storing the machine Cleaning If the implement is being put away for a short or longer period of time it is recommended that you clean it inside and outside. Outside cleaning For outside cleaning use the cleaning agents available on the implement or a high pressure cleaner.
• and valve B on pos 3 (Accessory position). Open valve C for pumping the clean water tank empty. Operation via the ISOMatch Choose the screen “Valve management” from the main screen. Empty Clean Water Choose the function Empty clean water tank.
Page 171
Storing the machine With the iXclean Comfort (option) If the implement is fitted with an electric suction valve the suction valve will be controlled automatically while emptying. Scroll from the main screen to the “Intake from Clean Water Tank” screen: Intake from clean water tank screen ...
Storing the machine Disconnecting the Disconnecting safely You may only disconnect the machine when: machine • all parts are in a safe condition, • your immediate surroundings are safe, Work carefully by: • checking the surroundings (children!) and ensuring that nobody is in the vicinity of the tractor or the machine, •...
Page 173
Storing the machine Preparation for winter The machine must be prepared for winter storage at the end of the season . storage Check the manual of your implement. Disconnect the pressure gauge with the quick coupling and let the spray line run empty.
Maintenance Repair damage safely and without delay Maintenance Repair the machine safely before you continue with work: • place the tractor and machine on a firm, straight surface, • switching off the PTO shaft, • releasing the pressure from the hydraulic system, •...
Page 175
Maintenance Tighten all bolts and nuts Check that all the nuts and bolts are well set. Check this again after one hour of use • after delivery and • carrying out maintenance or repair activities. Avoid contact with materials You may easily come into contact with materials when cleaning the machine.
Troubleshooting Troubleshooting Troubleshooting table Problem Possible cause Solution Pag. Set the spray volume as per the instruc- Spray volume incorrectly set tions Nozzle placement not checked by Carry out the gauging gauging Incorrect spray volume Pressure regulator Check the pressure regulator and flow (l per hectare) Flow meter meter to ensure they work properly...
Page 177
“Operation 2” screen Front tank functions Switching off “CANBUS termination” for are not controlled “CANBUS termination” is on ISOMatch correctly 1) All checks on the printed board in the SHC / control unit may only be performed by trained personnel!
The manufacturer has no kind of liability or guarantee (they become null and void) if non-genuine parts are used. ISOMatch control If you want complete ISO control, the ISOMatch control box offers many extra new functions. The latest developments in ISOBUS communication between tractor and machine and ease-of-use are all incorporated into the ISOMatch.
Page 179
Other connections are made via the "Input IM Tellus" cable, supplied as a standard item. Input IM Tellus with ISO11786 In cab connection A connection set is supplied as a standard item with the ISOMatch for: • ISO 11786 In cab •...
Page 180
Driving speed signal Your drawn implement issues its own driving speed signal If you use the IsoMatch power cable set to equip your non-ISO tractor for a non-ISO tractor with the ISOBUS communication system, it will also be issued a driving speed signal from your drawn machine.
Page 181
See the website www.IsoMatchshop.com ISOMatch Eye ISOMatch Eye is an accessory for better visibility, day and night. The camera must be connected to the ISOMatch Tellus (GO) terminal and offers additional safety regarding activities. See the website www.IsoMatchshop.com...
Sensor input IM Tellus Directly to the tractor radar or wheel sensor You can connect the tractor's speed sensor or radar to the ISOMatch control box with the optional "Sensor input IM Tellus". This is needed if your tractor does not have the ISO 11786 in cab connection.
Page 183
Accessories Wheel rings The wheel ring, mounted directly on the front wheel, provides a high number of pulses and thereby ensures an accurate reading. Two 254 mm types are available: • fixed ring with 254 mm inner diameter, • the divisible with 324 mm inner diameter. 324 mm Starguide With the Starguide you have the following functions:...
Page 184
Each buttons on the ISOMatch Grip can control one or more functions that are defined during the factory settings. See the user manual of the ISOMatch Grip for layout of the functions via the buttons. Boom Guide Spray The control can maintain the jet nozzle height very accurately by direct measurement on the soil or crop.
Page 185
Accessories iXclean Comfort automatic Additional control box with electric tank level gauge on the implement main tank filling system The iXclean Comfort is an extension of the control centre of your sprayer. The electric tank level measurement and (optional) electric suction valve measurement are controlled with this function.
Accessories iXclean Pro With the iXclean Pro option, you can electrically connect the following valves: iXclean Pro control box • Valve suction side • Valve on pressure side • tank cleaning valve Most functions can be operated on the FMA control box, in the tractor, and by using the iXclean Comfort box on the sprayer.
Decommissioning When the life cycle of the machine is over, its separate parts must be Decommissioning properly disposed of. Keep local legislation in mind herewith. Metal parts You must deliver all metal parts to a metal recycling company. Plastic parts All plastic parts can be disposed of as unwanted garbage.
Liability Liability Liability Without prejudice to the other stipulations of these General Conditions and the stipulations of the act on product responsibility, the seller is only liable for damage caused by culpable breach of contract and by unlawful act in the framework of the regulations below: 1.
Liability Complaints The following stipulations apply, along with national legislation: • The buyer must check the equipment, accessories and spare parts upon delivery for transport damage and completeness. Any possible shortcomings must be reported without delay. • The seller will only consider complaints if the buyer reports them in writing no later than fourteen days after delivery by the seller.
Ergodrive Conversion to ISO tractor GEOCONTROL software Correction value for the nozzle height IsoMatch coupling shaft IsoMatch Eye assembly IsoMatch GPS antenna ISOMatch InLine IsoMatch MultiEye ISOMatch Tellus GO Damping of the steering reaction IsoMatch Wireless decommissioning iXclean Comfort Decrease...
Page 192
Nozzles list ISO-bus control system IsoMatch control box Extra functions Person webshop authorisation IsoMatch Eye pictograms IsoMatch GPS antenna pull down menu ISOMatch InLine IsoMatch MultiEye ISOMatch Tellus GO IsoMatch Wireless radar cables iXclean Comfort RS-232 cable iXclean Pro Safety...
Page 193
Index control box wheel sensor Simulation speed winter storage replaces driving speed Work menu when starting spraying with GEOCONTROL site safety Site registration Speed signal Spray function with ERGODRIVE Sprayer control software Starguide Starguide ISOBUS address Start up sequence Steering system Stop stopping work storage...
Need help?
Do you have a question about the ISOMatch and is the answer not in the manual?
Questions and answers