Team Corally ULTRA-X 80 Instruction Manual

Multi chemistry 80w ac/dc balance charger 1-6s

Advertisement

Quick Links

MULTI CHEMISTRY 80W AC/DC BALANCE CHARGER 1-6S
1-6 Lixx Cells
1-15 Nixx Cells
2-20V PB
Téléchargez la version française ici.
Download de Nederlandse versie hier..
Laden Sie die deutsche Version hier herunter.
#C-51025
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ULTRA-X 80 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Team Corally ULTRA-X 80

  • Page 1 MULTI CHEMISTRY 80W AC/DC BALANCE CHARGER 1-6S 1-6 Lixx Cells 1-15 Nixx Cells 2-20V PB Téléchargez la version française ici. Download de Nederlandse versie hier.. Laden Sie die deutsche Version hier herunter. #C-51025 INSTRUCTION MANUAL...
  • Page 2: Warnings And Safety Notes

    Any attempts at disassembly, use with incompatible components, or alterations to the product must be approved by Team Corally. Only utilize accessories that are authorized and endorsed by Team Corally. This manual includes crucial safety, operation, and maintenance instructions. It is imperative...
  • Page 3 WARNINGS AND SAFETY NOTES • Never charge batteries in extremely hot or cold places or place in direct sunlight. • Never charge a battery if the cable has been pinched or shorted. • Never connect the charger if the power cable has been pinched or shorted. •...
  • Page 4 WARNINGS AND SAFETY NOTES WARNING: Never leave charger unattended, exceed maximum charge rate, charge with non-ap- proved batteries or charge batteries in the wrong mode. Failure to comply may result in excessive heat, fire and serious injury. Always ensure the battery you are charging meets the specifications of this charger and that the charger settings are correct.
  • Page 5 WARNINGS AND SAFETY NOTES difference between resistance of cable and connector, the charger can not detect resistance of the battery pack. The essential requirement for the charger to work properly is that the charge lead should be of adequate conductor cross-section, and high quality connectors which are normally gold-plated should be fitted to both ends.
  • Page 6: Specifications

    SPECIFICATIONS Operating voltage range: AC 100 - 240V DC 11 0~18 0V Battery Types: LIPO / LIHV / LIFE / LI-ION / NIMH / NICD / PB Circuit power: max 80W for charging max 5W for discharging Charge current range: 0 1~8 0A Discharge current range: 0 1~2 0A...
  • Page 7: Charger Layout

    CHARGER LAYOUT BATT TYPE/STOP - DEC / INC + START/ENTER To select main program To select sub programs To resume or start the To stop operation To alter the value operation Charge Output Balancer Port Input Power Cable 2-6S XH XT-60 connector DC11-18V Input Power Cable...
  • Page 8 FEATURES Optimised operating software When charging or discharging, it has an ‘AUTO’ function that sets the feeding current automatically. Especially for Lithium batteries, it can prevent the over-charging can lead to an explosion by users fault. Every program in the unit is controlled with mutual links and communication for every possible error so it introduces a maximum safety.
  • Page 9: Maximum Safety

    FEATURES Maximum safety Delta-peak sensitivity: The automatic charge termination program works on the principle of the Delta-peak voltage detection.(NiCd/NiMH) Auto-charge current limit: When charging NiCd or NiMH at ‘AUTO’ current mode, you can set the upper limit of change current to avoid from high current charging. This is very useful when charging the low impedance and small capacity NiMH battery in ‘AUTO’...
  • Page 10: Program Flow Chart

    PROGRAM FLOW CHART Start PROGRAM SELECT LIXX CHARGE LIXX BALANCE Enter LIXX FAST CHG LIXX STORAGE LIXX BATT Batt type stop PROGRAM SELECT NiMH CHARGE Start Enter NiMH DISCHARGE NiMH CYCLE LIXX DISCHARGE NiMH BATT 'Aut' / 'Man' Batt type stop PROGRAM SELECT Start...
  • Page 11: Initial Parameter Set Up (Users' Set Up)

    5. Initial Parameter set up (Users' set up) INITIAL PARAMETER SET UP It will be operated with the default value of the essential user settings when it is connected to a It will be operated with the default value of the essential user settings when it is connected to a 12V batttery for the first time.The screen displays the following 12V battery for the first time.
  • Page 12 INITIAL PARAMETER SET UP This shows the trigger voltage for automatic charge termination This shows the trigger voltage for automatic charge termination of NiMH and NiCd battery. The effective of NiMH and NiCd battery. The effective value ranges from 5 to value ranges from 5 to 20mV per cell .if the trigger 20mV per cell .if the trigger voltage is set higher, there is a danger voltage is set higher, there is a danger of overcharging...
  • Page 13: Charging Lithium Battery

    INITIAL PARAMETER SET UP This program sets the maximum charge capacity that will be sup- plied to the battery during charge. If the delta-pack voltage is not detected nor the safety timer expired by any reason, this feature will automatically stop the process at the selected capacity value. The beep sounds at every time pressing the buttons to confirm your action.
  • Page 14: Charging Lithium Battery At Balance Mode

    INITIAL PARAMETER SET UP This shows the number of cells you set up and the processor This shows the number of cells you set up and the This shows the number of cells you set up and the detects. ‘ R: ‘ shows the number of cells found by the charger and processor detects.
  • Page 15: Fast Charging Lithium Battery

    6.3 'FAST' charging Lithium battery FAST CHARGING LITHIUM BATTERY The charging current is getting smaller as the process goes to the near end term 6.3 'FAST' charging Lithium battery The charging current is getting smaller as the process goes to the near end term of Lithium battery of Lithium battery charging.
  • Page 16: Discharging Lithium Battery

    DISCHARGING LITHIUM BATTERY 6.5 Discharging Lithium battery The value of discharge current on the left side of screen may not The value of discharge current on the left side of exceed 1C for a maximum safety and the final voltage on the right 6.5 Discharging Lithium battery screen may not exceed 1C for a maximum safety and the final voltage on the right should not be under...
  • Page 17: Nimh/Nicd Battery Program

    NIMH/NICD BATTERY PROGRAM 7. NiMH/NiCd battery program These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cad- 7. NiMH/NiCd battery program mium) battery commonly used for R/C model applications. To alter the value at the display, press These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or Start/Enter key to make it blink then change the value using INC or DEC key.
  • Page 18: Charge/Discharge - Discharge/Charge Cycle Of Nimh/Nicd Battery

    7.3 Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery CHARGE/DISCHARGE - DISCHARGE/CHARGE CYCLE OF NIMH/NICD BATTERY 7.3 Charge-to-discharge & discharge-to-charge cycle NiMH/NiCd battery Set the sequence on the left and the number of cycle Set the sequence on the left and the number of cycle on the right. on the right.
  • Page 19: Discharging Pb Battery

    The audible sound indicates you at the end of process. The screen displays the state of charging process. To stop charging forcibly, press Batt type/Stop key once. The audible sound indicates you at the end of process. DISCHARGING PB BATTERY 8.2 Discharging Pb battery Set discharge current on the left and final voltage on the right.
  • Page 20: Save Data Program

    SAVE DATA PROGRAM It has the data storage and load program for your convenience. This feature can store up to 5 battery data by number that represent the individual specification of the batteries you are using. They can be called back for the process of charging or discharging without setting up the program again.
  • Page 21: Load Data Program

    LOAD DATA PROGRAM 11. Load Data Program This program calls back the data that was stored at ‘Save Data’ program. To load the data, press This program calls back the data that was stored at 'Save Data' program.To load 11. Load Data Program Start/Enter key once to blink the data number field and select the number using INC or DEC key the data, press Start/Enter key once to blink the data number field and select the then press Start /Enter key for more than 3 seconds.
  • Page 22: Warning And Error Messages

    INFORMATION DURING THE PROCESS The external temperature only will be displayed when using the The external temperature only will be displayed when thermal probe. using the thermal probe. The external temperature only will be displayed when using the thermal probe. The present voltage of input DC power.
  • Page 23 WARNIG / ERROR MESSAGES There happens the malfunction at the charger circuit There happens the malfunction at the charger circuit by any reason. by any reason . The processor detects the voltage is lower than you set at Lithium The processor detects the voltage is lower than you program.
  • Page 24: Invalidation Of The Warranty

    WARRANTY CONDITIONS & LIABILITY DISCLAIMER If material defects or manufacturing faults should arise in a product distributed or manufactured by CORALLY, a division of JSP Group Intl BVBA, and purchased by a consumer, we CORALLY acknowl- edge the obligation to correct those faults or defects within the limitations described below. This manufacturers warranty is in addition to, and does not affect, the legal or contractual rights of the consumer which arise from the purchase of such products.
  • Page 25: Applicable Law

    WARRANTY CONDITIONS & LIABILITY DISCLAIMER not be supervised by CORALLY. Therefore CORALLY is in no way liable for loss, damage, or costs resulting from improper use, or behaviour in any way connected to the above described provisions. Unless otherwise required by law, CORALLY is in no way whatever liable to provide compensation for damages arising from the improper use of the model (including personal injury, death, damage to buildings, loss of turnover, loss of business, or interruption of business, or any other direct, or indirectly caused, consequential damage).
  • Page 26 DECLARATION OF CONFORMITY CORALLY ULTRA-X 80 #C-51025-EU Hereby, Team Corally, a division of JSP Group Intl BV declares that the device is in compliance with the following: EU Low Voltage Directive 2014/35/EU; EU EMC Directive 2014/30/ EU; RoHS 2 Directive 2011/65/EU; RoHS 3 Directive...
  • Page 27: Fcc Information

    This manual is an edition of Team Corally - JSP Group Intl BV Geelseweg 80, B-2250 OLEN (Belgium). This manual is protected by a copyright and nothing from this edition may be reproduced or used without any prior written authorisation.
  • Page 28 JSP GROUP INTL BV - Geelseweg 80 • B-2250 Olen (Belgium) Tel: +32 14 25 92 94 • info@corally.com • www.corally.com...

Table of Contents