Do you have a question about the WWUSA-EZ3-SM and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Waterworld WWUSA-EZ3-SM
Page 1
MODEL WWUSA-EZ3-SM | WWUSA-EZ3-FM ELECTRONIC CONTROL VALVE Service Manual...
Page 2
Display Introduction & Features 1: Regeneration Mode 2: Time of day 3: Flow Indicator 4: Day of Week 5: Capacity Remaining/Regeneration Mode/Day override 6: SETTING BUTTON (1) Press and hold the Setting button for 5 seconds to enter Programming Mode. (2) When the valve is in Programming Mode, Press setting button return last display (3) Press and hold setting button for 5 sec under any display, back to service display (4) Press and hold, power on until the screen lights up to reset all parameter to the factory settings.
Page 3
Programming Mode Setting Press and hold the Setting Button for 5 seconds. Press "→" to enter the display for current time and week setting Default : 08:00 AM SUN (08:00 SUN-24 hours) Press "→" to move Press "↑" and "↓" to adjust the data Press"Setting Button"...
Page 4
Programming Mode Setting (Continued) Press "→" to enter Day Override setting Default : OFF Range:01~99 Days Press "↑" and "↓" to adjust the data Press"Setting Button" back to last display Press "→" to enter Regeneration Time setting Default : 02:00 AM (02:00 -24 hours) Press "↑"...
Page 5
Programming Mode Setting (Continued) Press "→" to enter Dosing Pump setting Default : OFF Press "→" to enter setting Press"Setting Button" back to last display ■ ON ■ Set volume to start the pump,Range:1~999 gallons Range:1~9999 liters Range:0.01~9.99 M3 ■ Set pump running time,Range:1~999 minutes Press "↑"...
Page 6
Programming Mode Setting (Continued) If the Regeneration Type is set to Hours Delayed Press "→" to enter Regeneration Times setting Default : 12 cycles regeneration every 24 hours, every 2 hours have one complete regeneration cycle Press "→" to enter setting,and then Press "→" to move Press "↑"...
Dimensional Drawing 182 mm 215 mm 7.17 inch 8.47 inch 161.7 mm 6.37 inch 216.7 mm 8.53 inch 66.8 mm 62 mm 2.63 inch 2.44 inch 182 mm 215 mm 7.17 inch 8.47 inch 161.7 mm 6.37 inch 216.7 mm 8.53 inch 62 mm 2.44 inch...
Troubleshooting [DETECTED ERROR 0] Probable Cause: Motor is stalled. Solution: Recover and Resetting Unplug the unit from the power source, When power is restored to the unit, the [DETECTED ERROR 0] display code clears. If the condition causing the error has not been resolved the [DETECTED ERROR 0] code reappears in the four digit display.
Page 16
Customsized Speci�cation TRANSFORMER DRAIN LINE FLOW CONTROL WASHERS(DLFC) WWUSA-17357005... .Transformer ,24V,CN WWUSA-21257239... .DLFC,0.8 GPM WWUSA-21247013... .DLFC,1.5 GPM WWUSA-17357018.