PRO AS180
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO AS180 and is the answer not in the manual?

Questions and answers

Summary of Contents for MedKlinn PRO AS180

  • Page 1 PRO AS180 USER MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Safety Precautions 2. Device Identification 3. Parts Identification 4. Installation 5. Operation 6. Service and Maintenance...
  • Page 3: Safety Precautions

    Any subsequent fault in operation of the device will not be covered by the warranty, and repair and maintenance service will be chargeable. 11. If the power cable is damaged, contact an authorized Medklinn Service Center for repairs immediately. 12. Do not wipe the device with benzene or paint thinner.
  • Page 4 NOTE – RISK OF INTEFERENCE AND OTHER POSSIBLE DISRUPTIONS: 1. If the device interferes or disrupts with other electronic equipment and/or machineries, attempt one or more of the following measures: Relocate or increase the distance between the device and the electronic equipment and/or machineries. •...
  • Page 5 CAUTIONS DURING OPERATION 1. Do not cover the device in any way at all, particularly the ventilation holes. Doing so will cause excessive heat build-up and may result in a fire or irreparable damage to the device. 2. Avoid placing the device where curtains or other furnishings may cover the ventilation holes or any holes of the device. 3.
  • Page 6: Device Identification

    DEVICE IDENTIFICATION Functional Parts Air inlet from environment. Ventilation Holes (Air Inlet) Ventilation Holes Active Oxygen is disbursed through the outlet. (Active Oxygen Outlet) PRO AS180 (Front View)
  • Page 7 DEVICE IDENTIFICATION Functional Parts To select operation mode. Control Button LED light I Operation mode LOW. LED light II Operation mode MID. LED light III Operation mode HIGH. PRO AS180 (Top View)
  • Page 8: Parts Identification

    PARTS IDENTIFICATION Functional Parts Power Cord Cable (2.5m)
  • Page 9: Installation

    INSTALLATION Remove the back cover screws and remove the back cover by pushing it up. Insert the power cord cable to the device’s plug point.
  • Page 10 Installation methods:- A. Standalone on the floor (Page 10-11). Mounted on the wall (Page 12). A. STANDALONE ON THE FLOOR Align the power cord cable with the edge as circled below.
  • Page 11 Slot the back cover back in, align the power cord cable to exit from the slot of the back casing and fasten the back cover screw.
  • Page 12 B. MOUNTED ON THE WALL Fix 2 pieces 4mm diameter self-taping screws onto the wall with 79mm apart. Mount the device to the self taping screws on the wall.
  • Page 13 Installation guides:- A. Device needs a minimum clearance radius of 2m from any objects. Device’s ventilation holes must be facing the front. Ventilation holes facing front...
  • Page 14: Operation

    OPERATION Turn on the device’s power point, when the device is powered up, LED light I will light up by default. Control Button Press the control button to advance to the next mode (LOW/MID/HIGH). To activate iKlinn function, press the control button for approximately 3 seconds until the LED lights blink and vice versa.
  • Page 15: Service And Maintenance

    SERVICE AND MAINTENANCE To maintain its optimal performance, cleaning of module and filter is recommended every 3 to 6 months. NOTE: Frequent cleaning is advised if the device is placed in environment with higher humidity (e.g., >70% relative humidity). As this will result in oxidation residue build up on the module and affect its performance. A.
  • Page 16 iii. Remove the screws at the bottom back plate and open the bottom back plate.
  • Page 17 Use a brush* to clean the module. After brushing, wipe with damp cloth. (*Brush is not provided) Module...
  • Page 18 Fasten the screws of the bottom back plate. Insert the power cord cable, back casing and plug it back to the power point.
  • Page 19 Cleaning of Filter Remove the screws at the top back plate and pull out the top black plate.
  • Page 20 Remove the filter’s top housing using a flat screwdriver at the slot provided.
  • Page 21 iii. Remove the filter and wash. Dry the filter after washing. Filter Top Housing Filter...
  • Page 22 Insert the filter back in place and reinstall the filter’s top housing. Insert the top back plate back into the main housing and fasten screws.
  • Page 23 Annual preventive maintenance for the Medklinn Air+Surface Sterilizers is recommended to ensure optimal performance, otherwise it may experience malfunction or possibly cause damage to internal components. FOR ANNUAL PREVENTIVE MAINTENANCE ARRANGEMENTS, PLEASE CONTACT AN AUTHORIZED MEDKLINN SERVICE CENTRE.
  • Page 24 For more information, please login to www.medklinn.com...