Compaq 108164-003 - ProLiant - 800 White Paper page 14

Novell groupwise performance management on compaq servers
Hide thumbs Also See for 108164-003 - ProLiant - 800:
Table of Contents

Advertisement

ECG007.0897
W
P
HITE
APER
(cont.)
. .
. .
The following levels of fault tolerance support are available:
. .
. .
RAID 5 - Distributed Data Guarding
. .
. .
RAID 4 - Data Guarding
. .
. .
RAID 1 - Disk Mirroring
. .
. .
. .
RAID 0 - No Fault Tolerance Support
. .
. .
The Compaq Smart-2 Array Controller is needed to support hardware striping and all levels of
. .
. .
fault tolerance support. Features offered by the Compaq Smart-2 Controllers that are not found
. .
with Fast-Wide SCSI-2 Controllers are:
. .
. .
Support for RAID 0, RAID 1, RAID 4 and RAID 5 Hardware
. .
. .
Striping and Fault Tolerance
. .
. .
Dual Fast-Wide SCSI-2 channels on a single board support up to
. .
. .
14 drives (7 per channel)
. .
. .
Support for multiple logical drives per drive array
. .
. .
Removable Array Accelerator - battery-backed 4 MB Read/Write
. .
. .
cache with Error Checking and Correcting (ECC)
. .
. .
Read-ahead caching
. .
. .
. .
Online Capacity Expansion and Disk Drive Upgrades
. .
. .
Fault Management Features
. .
. .
. .
RAID 5 - Distributed Data Guarding
. .
. .
. .
RAID 5 is also referred to as distributed data guarding because it uses parity data to guard against
. .
the loss of data. The parity data is distributed or striped across all the drives in the array. RAID 5
. .
. .
provides very good data protection because if a single drive fails, the parity data and the data on
. .
the remaining drives is used to reconstruct the data on the failed drive. With Compaq Smart-2
. .
. .
controller technology, this reconstruction process allows the failed drive to be replaced while the
. .
system continues to operate at a slightly reduced performance. RAID 5 also offers good
. .
. .
performance because spreading the parity across all the drives allows more simultaneous read
. .
operations.
. .
. .
The usable disk space when using RAID 5 depends on the total number of drives in the array. If
. .
. .
there are three drives, 67 percent of the disk space is usable for data, with the remainder being
. .
used to support fault tolerance. If there are fourteen drives, 93 percent of the disk would be
. .
. .
available. The tests that follow used seven drives.
. .
. .
. .
RAID 1 - Drive Mirroring
. .
. .
RAID 1 is also referred to as drive mirroring. This is typically the highest performance fault
. .
tolerance method. RAID 1 is the only option for fault tolerance if no more than two drives are
. .
. .
selected. Drive mirroring works as its name implies, storing two sets of duplicate data on a pair of
. .
disk drives. Therefore, RAID 1 always requires an even number of disk drives. From a cost
. .
. .
standpoint, RAID 1 is the most expensive because 50 percent of the drive capacity is used for fault
. .
tolerance.
. .
. .
. .
If a drive fails, the mirror drive provides a backup copy of the data and normal system operation
. .
is not interrupted. A system with more than two drives may be able to withstand multiple drive
. .
failures as long as the failed drives are not mirrored to one another.
. .
. .
. .
14

Advertisement

Table of Contents
loading

Table of Contents