  • Page 1 D000085279.0002 - 01 Operating instructions CMSVT38 Vibration and temperature sensor...
  • Page 2: Table Of Contents

    4.10.1 Product conformity ..................4.10.2 Dimensions ....................4.10.3 Temperature detection................Scope of Delivery ......................Condition-monitoring sensor CMSVT38 ..............Preparations for installation and commissioning............Installation ........................Mechanical Installation.................... 7.1.1 General Information for the Installation of Condition-Monitoring Sensors 7.1.2 Cable Routing ...................
  • Page 3 Fritz Kübler GmbH Table of contents Commissioning ....................... Status LEDs ......................Settings ..........................Functions and properties that can be set..............Setting via FDT/IODD ..................... 10 Maintenance ........................10.1 Reassembly ......................11 Software-Supported IO-Link Parameterization ............12 IO-Link-Parameter ......................12.1 IO-Link-Parameter ....................12.1.1 General Parameters .................
  • Page 4: Document

    1 Document Fritz Kübler GmbH 1 Document This is the original Operating instructions, source language German. Publisher Kübler Group, Fritz Kübler GmbH Schubertstraße 47 78054 Villingen-Schwenningen Germany www.kuebler.com Date of issue 02/2025 Document no. D000085279 ©  Copyright 2025, Kübler Group, Fritz Kübler GmbH Legal information All contents of this document are subject to the rights of use and copyright Fritz Kübler GmbH.
  • Page 5: Change Information

    Fritz Kübler GmbH 2 Change information 2 Change information Index Chapter Changes Date Name Initial document 2/27/2025 D000085279.0002 - 01 EN | 5...
  • Page 6: General Information

    3 General information Fritz Kübler GmbH 3 General information Read this document carefully before working with the product. It guides you or the technical personnel of the machine and plant manufacturer or operator in the safe assembly, installation, commissioning, and operation of the product.
  • Page 7: Symbols Used/Classification Of Warnings And Safety Instructions

    Fritz Kübler GmbH 3 General information 3.2 Symbols used/classification of warnings and safety instructions Classification: DANGER This symbol, in connection with the signal word DANGER, warns of an imminent danger to the life and health of persons. Failure to observe this safety instruction will result in death or serious damage to health.
  • Page 8: Applicable Documents

    3 General information Fritz Kübler GmbH The storage must: • be free of any compressive stress to prevent damage or deformation. • be dry, dust-free, and in accordance with the technical data, see chapter "Technical Data [} 12]” or "Applicable documents [} 8]”. 3.6 Applicable documents Technical Data All technical data, as well as mechanical and electrical characteristics, can be found in the data...
  • Page 9: Product Description

    Due to different electrical operating conditions in the sensor, the measured temperature may differ from the ambient temperature. 4.2 Intended Use The CMSVT38 series condition-monitoring sensors monitor temperature and vibration of machines. The process values are output by the device via IO-Link.
  • Page 10: Examples Of Applications

    Fritz Kübler GmbH 4.3 Examples of Applications Combination CMSVT38 with signal column and IO-Link master In IO-Link mode, the vibration sensor CMSVT38 can be connected to an Ethernet network via an IO-Link master. By communicating with the controller, the IO-Link signal column ST40, for example, can signal the detected statuses on site again.
  • Page 11: Functions And Operating Modes

    IO-Link, which output the oscillation acceleration or the oscillation speed depending on the parameterization. The vibration acceleration or vibration speed can be output as an RMS value or a peak-to-peak value. Additionally, the vector sum is output as a 16-bit telegram. Fig. 1: CMSVT38 Measuring axes IMG-ID: 404805515 D000085279.0002 - 01...
  • Page 12: Technical Data

    4 Product description Fritz Kübler GmbH 4.10 Technical Data NOTICE Technical Data All technical data, as well as mechanical and electrical characteristics, can be found in the data sheets of the corresponding product versions, or in the corresponding bid / customer drawing of the product for specially-designed models.
  • Page 13: Scope Of Delivery

    Fritz Kübler GmbH 5 Scope of Delivery 5 Scope of Delivery 5.1 Condition-monitoring sensor CMSVT38 The scope of delivery includes: • Condition-monitoring sensor • Supplement with QR code and link to https://www.kuebler.com/ D000085279.0002 - 01 EN | 13...
  • Page 14: Preparations For Installation And Commissioning

    6 Preparations for installation and commissioning Fritz Kübler GmbH 6 Preparations for installation and commissioning Please observe the following instructions before beginning to install the condition-monitoring sensor. ATTENTION Damage to the product due to transport or storage Product failure, malfunction, reduction of the product service life. •...
  • Page 15: Installation

    Fritz Kübler GmbH 7 Installation 7 Installation 7.1 Mechanical Installation ATTENTION Damage to the product due to transport or storage Product failure, malfunction, reduction of the product service life. • Check the packaging and the product for possible damage. • Do not use or operate the product in the event of visible damage. •...
  • Page 16: Installation Instructions For Condition-Monitoring Sensors

    7 Installation Fritz Kübler GmbH • Separate the wiring in line groups such as motor and power supply lines as well as signal and data lines. • Route the signal and data cables as closely as possible to ground surfaces (support beams, metal rails, cabinet panels) and not parallel to motor and power supply lines or other lines with a high level of interference.
  • Page 17: Electrical Installation

    Fritz Kübler GmbH 7 Installation 7.2 Electrical Installation 7.2.1 General Instructions for the Connection ATTENTION Destruction of the device Before plugging or disconnecting the signal line, always disconnect the supply voltage and secure it against being switched on again. NOTICE General safety instructions Make sure that the entire system is de-energized during electrical installation.
  • Page 18: Connecting The Connection Wires

    7 Installation Fritz Kübler GmbH IMG-ID: 9007199375147403 Order code 8.0000.4G06.0312 8.0000.4G06.0718 Material Spring steel, galvanized Shield diameter 3.0 … 12.0 mm 7.0 … 18.0 mm Kübler offers a wide range of connection cables in various designs and lengths, see www.kuebler.com/anschlusstechnik. Kübler provides various solutions for EMC-compliant installation, e.g. shielding clamps for the control cabinet, see www.kuebler.com/zubehoer.
  • Page 19: Sensor Terminal Assignment

    Fritz Kübler GmbH 7 Installation 7.2.4 Sensor Terminal Assignment • Connect the coupling of the connecting cable to the plug of the sensor. • Connect the open end of the connecting cable to the power source and/or the evaluation devices. Interface M12 connector, male pin, 4-pin, A-coded Signal:...
  • Page 20: Commissioning

    8 Commissioning Fritz Kübler GmbH 8 Commissioning After connecting and switching on the supply voltage, the device is automatically operational. 8.1 Status LEDs Fig. 4: Status LED IMG-ID: 404421899 Display Meaning PWR/ Green Device ready for operation Green, flashing IO-Link communication active Out 1 Yellow Switching status switching output 1 (parameterizable)
  • Page 21: Settings

    Fritz Kübler GmbH 9 Settings 9 Settings 9.1 Functions and properties that can be set Parameter Meaning Reset device The device is restarted. The communication is temporarily interrupted. The measured maximum values of the vibration are reset. Reset application The application-specific parameters are reset. Communication is not interrupted.
  • Page 22 9 Settings Fritz Kübler GmbH Parameter Meaning ISO 10816-3 The ISO 10816-3 standard specifies the exact vibration limits for industrial machines. The vibration limit values are used to assess industrial machines with a power of ≥15 kW and a rated speed of 120 rpm.
  • Page 23: Setting Via Fdt/Iodd

    Fritz Kübler GmbH 9 Settings Parameter Meaning Time slots The effective values of the vibration speed, acceleration or peak-to- peak values are determined and output over the set period of time. The following time windows for vibration detection can be defined: •...
  • Page 24: Setting Options

    9 Settings Fritz Kübler GmbH 24 V DC Fig. 5: Setting of switching outputs using IO-Link master IMG-ID: 407225867 1 Vibration sensor 2 IO-Link Master USB 3 Application 4 Adapter cable 5 USB interface 6 Laptop with software Connection The vibration sensor ① is or will be disconnected from the application ③. The IO-Link Master USB ②...
  • Page 25: Maintenance

    Fritz Kübler GmbH 10 Maintenance 10 Maintenance Troubleshooting If the device does not function as expected, check whether there is ambient interference. If there is no ambient interference, check the device connectors for errors. If none are present, there is a device fault. In this case, take the device out of service and replace it with a new device of the same type.
  • Page 26: Software-Supported Io-Link Parameterization

    11 Software-Supported IO-Link Parameterization Fritz Kübler GmbH 11 Software-Supported IO-Link Parameterization The ports of the IO-Link master can be configured in IO-Link mode (IOL) or in Standard IO mode (SIO). When a port is configured in SiO mode, the IO-Link master on that port behaves like a normal digital input.
  • Page 27: Io-Link-Parameter

    Fritz Kübler GmbH 12 IO-Link-Parameter 12 IO-Link-Parameter 12.1 IO-Link-Parameter 12.1.1 General Parameters Parameter Contents Vendor ID Vendor Name Fritz Kuebler GmbH Device ID 0x700011 IO-Link version Bitrate COM3 Minimum cycle time 1.3 ms Supports SIO True M-Sequence Capability PREOPERATE = TYPE_1_2 with 2 octet data on request OPERATE = TYPE_2_V with 2 octet data on request ISDU supported Block parameters...
  • Page 28 12 IO-Link-Parameter Fritz Kübler GmbH Name Byte.Bit Subindex Data Value Description offset length access Type supported X-axis True UInteger 0…65535 Resolution in 0.01 g or mm/s Y-axis True UInteger 0…65535 Resolution in 0.01 g or mm/s Z-axis True UInteger 0…65535 Resolution in 0.01 g or mm/s Magnitude True...
  • Page 29: Standard Parameters

    Fritz Kübler GmbH 12 IO-Link-Parameter 12.1.3 Standard Parameters Name Index Index Sub- Sub- Subindex Acces Byte.Bit Data Value De- Description (dec) (hex) index index access offset length Type fault (dec.) (hex.) supported Minimum cycle True read UInteger time IO-Link Version True read UInteger...
  • Page 30 12 IO-Link-Parameter Fritz Kübler GmbH Name Index Index Sub- Sub- Subindex Acces Byte.Bit Data Value De- Description (dec) (hex) index index access offset length Type fault (dec.) (hex.) supported Local user False Read/ Boolean false/ Block device access interface block write true Manufacturer...
  • Page 31: Parameter

    Fritz Kübler GmbH 12 IO-Link-Parameter 12.1.4 Parameter Name Index Index Subin Subin Subindex Acces Byte. Data Value Default Description (dec) (hex) access length Type supported offset (dec.) (hex.) Function tag 25 0x19 True read/ String NaN... The parameter contains the write description of the function of a profile device in an...
  • Page 32 12 IO-Link-Parameter Fritz Kübler GmbH Name Index Index Subin Subin Subindex Acces Byte. Data Value Default Description (dec) (hex) access length Type supported offset (dec.) (hex.) Group 3 flexible Group 4 rigid Group 4 flexible Temperature manual X-axis pre- 0x 104 1 True read/ 14.0...
  • Page 33 Fritz Kübler GmbH 12 IO-Link-Parameter Name Index Index Subin Subin Subindex Acces Byte. Data Value Default Description (dec) (hex) access length Type supported offset (dec.) (hex.) Operating 0x 106 0 True read UInteger NaN... Time in hours during which hours the device is in operation counter Process data...
  • Page 34 12 IO-Link-Parameter Fritz Kübler GmbH Name Index Index Subin Subin Subindex Acces Byte. Data Value Default Description (dec) (hex) access length Type supported offset (dec.) (hex.) Self-test Self-test, 0x 10B 0 True read UInteger 0…2 Result of the self-test result Device not tested Device is not in order Device is in order...
  • Page 35 Fritz Kübler GmbH 12 IO-Link-Parameter Name Index Index Subin Subin Subindex Acces Byte. Data Value Default Description (dec) (hex) access length Type supported offset (dec.) (hex.) Output 2 0x 110 0 True read/ UInteger 0…1 Configuration of the second Configuratio write output Alarm...
  • Page 36: Disposal

    13 Disposal Fritz Kübler GmbH 13 Disposal Always dispose of unusable or irreparable products in an environmentally friendly manner in accordance with country-specific requirements and valid waste disposal regulations. We are happy to help you with the disposal of the products. See chapter Contact [} 37].
  • Page 37: Contact

    Fritz Kübler GmbH 14 Contact 14 Contact If you want to get in touch with us: Technical advice For technical advice, analysis or support during installation, Kübler is available directly on site with its global application team. Support International (English-speaking) +49 7720 3903 849 support@kuebler.com Kübler...
  • Page 38: Appendix

    15 Appendix Fritz Kübler GmbH 15 Appendix 15.1 Conversion Table Decimal/Hexadecimal 0x33 0x66 0x99 0xCC 0x34 0x67 0x9A 0xCD 0x35 0x68 0x9B 0xCE 0x36 0x69 0x9C 0xCF 0x37 0x6A 0x9D 0xD0 0x38 0x6B 0x9E 0xD1 0x39 0x6C 0x9F 0xD2 0x3A 0x6D 0xA0 0xD3...
  • Page 39: Conversion Table Data Types

    Fritz Kübler GmbH 15 Appendix 0x1F 0x52 0x85 0xB8 0xEB 0x20 0x53 0x86 0xB9 0xEC 0x21 0x54 0x87 0xBA 0xED 0x22 0x55 0x88 0xBB 0xEE 0x23 0x56 0x89 0xBC 0xEF 0x24 0x57 0x8A 0xBD 0xF0 0x25 0x58 0x8B 0xBE 0xF1 0x26 0x59 0x8C...
  • Page 40: Glossary

    Glossary Fritz Kübler GmbH Glossary BOOL SINT Data type, a BOOLEAN, stands for a Data type, short integer, an operand of truth value that can be either true or the data type SINT (Short INT) has a false. length of 8 bits and consists of two components: a sign and a numerical value.
  • Page 41 Kübler Group Fritz Kübler GmbH Schubertstr. 47 D-78054 Villingen-Schwenningen Germany Phone +49 7720 3903-0 Fax +49 7720 21564 info@kuebler.com www.kuebler.com...