metrofires Ultra Tiny Rad Installation And Operation Manual

Freestanding ultra wood fires

Advertisement

Quick Links

FREESTANDING
ULTRA WOOD FIRES
Wood fire installation and operation manual
Important installation information ...................................................................................2
Assembling your Metro fire .................................................................................................2
Firebox parts and components ....................................................................................... 3
Floor protectors ...........................................................................................................................5
Flue installation .......................................................................................................................... 6
Clearances and specifications ..........................................................................................7
Important operation information ..................................................................................... 8
19 Oropuriri Road, New Plymouth 4312
info@metrofires.co.nz | www.metrofires.co.nz
Getting to know your Metro fire .......................................................................................9
Operating your Metro fire .....................................................................................................9
Cleaning and maintenance ...............................................................................................11
Troubleshooting ........................................................................................................................13
Metro Fires warranty .............................................................................................................14
Replacement parts ..................................................................................................................15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Tiny Rad and is the answer not in the manual?

Questions and answers

Summary of Contents for metrofires Ultra Tiny Rad

  • Page 1: Table Of Contents

    Firebox parts and components ..................3 Cleaning and maintenance ....................11 Floor protectors ...........................5 Troubleshooting ........................13 Flue installation .......................... 6 Metro Fires warranty ......................14 Clearances and specifications ..................7 Replacement parts ........................15 Important operation information ..................8 19 Oropuriri Road, New Plymouth 4312 info@metrofires.co.nz | www.metrofires.co.nz...
  • Page 2: Important Installation Information

    IMPORTANT INSTALLATION INFORMATION All Metro freestanding fires have been tested and approved to AS/NZS 2918 with a ceiling height of 2.4m (+/-0.1m) with a Pioneer WARNING! Important Information double flue shield fitted. WE HIGHLY RECOMMEND YOU READ THIS ENTIRE MANUAL All Metro fires comply with AS/NZS 2918 when installed in AS INCORRECT OPERATION, MISUSE AND/OR LACK OF accordance with this manual.
  • Page 3 Ultra Tiny Rad and Ultra Xtreme Rad baffle Check to ensure the top baffle is in its correct position in the top chamber Lift the rear of the baffle 20mm to clear the rear support lugs and slip of the firebox.
  • Page 4 FIREBOX PARTS AND COMPONENTS - FAN UNIT (Ultra Xtreme Rad model only) WARNING! Important Information • A registered electrician is required to replace the fan motor and thermostat if necessary • Use authorised Metro replacement parts only. The use of unauthorised parts will void the warranty and compliance •...
  • Page 5: Floor Protectors

    FLOOR PROTECTORS Pioneer manufacture an extensive range of Pioneer ‘ A sh Floor Protectors’ which comply with the minimum floor protector requirements of Cooktop AS/NZS 2918 and can be installed with any freestanding Metro wood fire. Metro freestanding wood fires do not require an insulated floor protector as they comply with the minimum floor protector requirements of AS/NZS 2918.
  • Page 6: Flue Installation

    Metro fires flue outlet. This is critical for optimum operation. A copy of the ECO Flue System installation manual can be downloaded from metrofires.co.nz, or a copy can be obtained from your Metro retailer. All Metro fires have been tested with a Pioneer double flue shield. For the...
  • Page 7: Clearances And Specifications

    The Ultra Tiny Rad installed with a Pioneer double flue shield and the Pioneer corner wing shields fitted allows for reduced clearances as follows: Ultra Tiny Rad corner clearance (E) can be reduced to 125mm. This in turn also reduces clearances (D) to 396mm, (K) to 1171mm and (L) to 943mm. When fitting the Corner Wing Shields the Ultra Tiny Rad must be installed to a corner clearance (E) of not less than 125mm.
  • Page 8: Important Operation Information

    WARNING! Important Information CAUTION! Important Information WE HIGHLY RECOMMEND YOU READ THIS ENTIRE MANUAL THIS APPLIANCE MUST BE MAINTAINED AND OPERATED AT AS INCORRECT OPERATION, MISUSE AND/OR LACK OF ALL TIMES IN ACCORDANCE WITH THIS MANUAL MAINTENANCE WILL VOID THE WARRANTY •...
  • Page 9: Getting To Know Your Metro Fire

    GETTING TO KNOW YOUR METRO FIRE There is a single air control making your fire easy to adjust. The air control moves from left to right, which is ‘low to high’ . Slide this control knob gently from right to left until you reach a stop. This is a pre-set ‘low’ position. Your Metro must not be operated at a lower burn rate than this setting.
  • Page 10 OPERATING YOUR METRO FIRE The Metro Ultra Fires outperformed the testing standards for emissions Step 2 - Intermediate load / Air control full open (high): allowing them to be installed into homes throughout New Zealand. Metro • Reloading is actioned once the majority of the flame has died away Ultra Fires meet the specification of ECAN’s Ultra Low Emission standards which is approximately 30-40 minutes after lighting.
  • Page 11: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Door glass WARNING! Important Information Providing your fuel is properly seasoned, under normal operating conditions the air-wash design of the Metro’s firebox will keep the door WE HIGHLY RECOMMEND YOU READ THIS ENTIRE SECTION AS glass clear. LACK OF MAINTENANCE AND SERVICING PARTS AS REQUIRED MAY VOID THE WARRANTY If the glass requires cleaning you may use either a razor blade scraper or...
  • Page 12 CLEANING AND MAINTENANCE Air slide adjustment The flue pipe should also be swept a minimum of once a year, or as required during the winter season. If smoke enters the room when you The cold start boost is controlled by a bimetal coil positioned on the air open the Metro’s door this usually indicates the flue pipe is becoming slide.
  • Page 13: Troubleshooting

    TROUBLESHOOTING If your Metro is installed correctly, your fuel is dry and you operate your Air turbulence and/or negative air pressure influences around the flue fire correctly, you will find it to be a pleasure to use. Metro’s many years of termination can be caused by too close or overhanging trees or natural/ experience within the wood heating industry has shown that dissatisfaction artificial ridges etc.
  • Page 14: Metro Fires Warranty

    WARRANTY • This warranty covers appliance like for like replacement or repair at CAUTION! Important Information the manufacturer’s discretion but excludes freight, travel, installation, labour and/or any other associated costs Your Metro fire must be regularly maintained and we recommend •...
  • Page 16: Replacement Parts

    • HEATING ACCESSORIES • WETBACK SYSTEMS • CATALOGUES AND INSTALLATION MANUALS • NES TEST CERTIFICATES • MAINTENANCE AND SERVICING • PRODUCT VIDEOS AND HOW-TO GUIDES • TROUBLESHOOTING 19 Oropuriri Road, New Plymouth 4312, New Zealand • FAQ’S info@metrofires.co.nz | www.metrofires.co.nz...

This manual is also suitable for:

Ultra wee radUltra xtreme rad

Table of Contents