Ductless floating air select single zone r- 32 refrigerant (127 pages)
Summary of Contents for Friedrich FA SELECT FSHSR09B1C
Page 1
Ductless Split Single Zone Outdoor Unit R-32, R-454B Refrigerant Models FA SELECT 115 VOLT FSHSR09B1C, FSHSR12B1C FA SELECT 208/230 VOLT FSHSR18B3D, FSHSR24B3D, FA PRO 115 VOLT FPHSR09A1C, FPHSR12A1C FA PRO 208/230 VOLT FPHSR09A3D, FPHSR12A3D, FPHSR18A3D, FPHSR24A3D, FSHSR36B3D THE EXPERTS IN ROOM AIR CONDITIONING 96111103_00...
Register your Air Conditioner Model information can be found on the name plate. Please complete and mail the owner registration card furnished with this product, or register online at www.friedrich.com. Protection A. IMPORTANT SAFETY AND GENERAL INFORMATION ....3 A.1 Introduction ................3 A.2 •...
A. IMPORTANT SAFETY AND GENERAL INFORMATION A.1 Introduction This booklet contains the installation and operating instructions for your Air Conditioning unit. There are some precautions that should be taken to ensure proper operation. Improper installation can result in unsatisfactory operation or dangerous conditions. Read this booklet and any instructions packaged with separate equipment required to make up the system prior to installation.
CAUTION: Do Not Operate Equipment During Active Stages Of Construction To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active stages of completing framing, drywalling, spackling, sanding, painting, flooring, and moulding in the equipment’s designated conditioning space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of our standard warranty guidelines.
This manual is subject to change without notice. Scan this QR code to be linked to the Friedrich professional support page where you can locate the most up to date Installation and operation Manual, Remote Control Manual, and Service Manual.
C. INSTALLATION OF THE UNIT C.1 Tools Verify with tool manufacturers that all tools used during servicing of the refrigerant are non-sparking and can be used with A2L Refrigerants. No halide torches for leak testing. Refrigerant monitors or detectors must be used to detect refrigerant in the work area. •...
C. INSTALLATION OF THE UNIT C.2 Clearances Distance from any obstacle should be over 20 inches from the top of the unit Air intake distance from the wall should be over 10 inches. Over 10 inches Figure C.2...
C. INSTALLATION OF THE UNIT C.3 Pre-Installation Checkpoints • Location is convenient to install and well ventilated. • Avoid installing it where flammable gas could leak. • Keep the required distance from walls and other obstacles. • Keep the outdoor unit away from grease and debris. Site Instructions •...
C. INSTALLATION OF THE UNIT C.4 Install Condensate Drain C.6 Piping Connections to Outdoor Unit 1. Remove service valve cover( if provided) to access the service valves and refrigerant ports. Install Condensate Drain for Outdoor Unit 2. Carefully bend and adjust length of refrigerant pipes to meet The condensate drains from the outdoor unit when the unit operates outdoor unit service valves connection with proper tools to avoid in heating mode.
E. ELECTRICAL E.1 Specifications Model Wire Diameter(AWG) Main Power Supply To Outdoor Unit Interconnecting Wire between Indoor and Wire Size MOP (Rating of Over MCA (Minimum Circuit Outdoor Unit current Device) Ampacity) FPHSR09A1C 14-4 AWG 600V THHN Size according to Local and National Electrical FPHSR09A3D 14-4 AWG 600V THHN...
G. LEAK CHECK, CHARGING AND TRIPLE EVACUATION • Recovery cylinders must have a minimum service pressure rating of 400 psig, (DOT 4BA400 and DOT BW400 approved cylinders). Warning: • POE (Polyol-Ester) lubricants must be used with R-32 or R-454B No ignition sources: No person carrying out work in relation to a equipment.
Page 13
G. LEAK CHECK AND CHARGING AND TRIPLE EVACUATION Friedrich requires all installations are Leak Checked and Evacuated in accordance to the “triple evacuation” process. This process promotes a dry tight refrigeration system before opening the service valves. It recommended that a single port refrigeration manifold and hoses rated over 31.5psi be used.
Operation Manual, all accessory installation instructions, and the name, Is heat insulation of It may cause condensation and address, and telephone number of the Authorized Friedrich Warranty pipeline sufficient? water dripping. Service Company in the area for future reference if necessary. Inspect It may cause condensation and the unit for any damage to the coils and tubing that could cause a leak.
Page 18
ESPAÑOL lnstrucciones de seguridad / • 1. Para garantizar que la unidad funcione con normalidad, leer cuidadosamente el manual antes de la instalaci6n y realizar la instalaci6n siguiendo este manual. • 2. A l mover el aire acondicionado, no dejar que el aire ingrese al sistema de refrigeraci6n o a la descarga del refrigerante.
ESPAÑOL Precauciones de seguridad / • Los sfmbolos en este Manual de Uso y Cuidado se especifican a continuaci6n. No hacerlo. La conexi6n a tierra es esencial. Advertencia: El manejo incorrecto Prestar atenci6n a la situaci6n. puede causar serios peligros como la muerte, lesiones graves, etc.
Page 25
lnstrucciones para la instalaci6n / ESPAÑOL lnstrucciones del sitio Unidad externa Sitio para instalar la unidad externa • Donde sea conveniente instalar y muy ventilado. La longitud de la tuberia • Evite instalar donde haya fugas de gas inflamable. es 20 metros (65,4 pies) •...
Page 28
lnstrucciones para la instalaci6n / ESPAÑOL Energia y cableado Conexi6n de/ cable • Unidad externa Chasis 1) Quitar el tablero de la unidad desajustando el tornillo. Tablero de cableado Conectar los cables a la terminal del tablero de manera individual de la siguiente manera. 2) Asegurar el cable de alimentaci6n en el tablero de control con una abrazadera.
Page 29
ESPAÑOL El diagrama es solo de referencia; se deben seguir los terminales reales del producto.
FRANÇAIS Consignes de securite • 1. Afin de garantir le fonctionnement correct de cet appareil, merci de lire attentivement cette notice avant d'installer le climatiseur, en tenant de respecter les consignes qui y sont livrees. • 2. Ne laissez l'air penetrer ni a l'interieur du systeme de refrigeration ni a l'interieur du systeme d'evacuation du liquide frigorigene lorsque vous deplacez l'appareil.
Consignes d'installation / FRANÇAIS Consignes relatives au site Site destine a accueillir /'unite exterieure Unite exterieure • Partout ou l'appareil peut etre installs facilement et ou une bonne La longueur de la ventilation existe. conduite est de 20 • E vitez d'installer l'appareil ou ii existe un risque possible de gaz metres max.
Page 43
FRANÇAIS Consignes d'installation / Alimentation et cablage Raccordement du cable • Unite exterieure 1 )Retirez la section de cable de l'unite en desserrant les vis. Connectez les cables aux bornes individuellement au panneau de controle, de la fa9on suivante. 2)Securisez le cordon d'alimentation sur le panneau de controle au moyen d'une pince.
Page 44
FRANÇAIS Le diagramme est uniquement une référence, les bornes réelles du produit doivent être suivies.
Page 45
FRANÇAIS Consignes d'installation / Charge et decharge Le circuit est charge en humidite et en eau, ce qui peut entrainer un dysfonctionnement du compresseur. Apres avoir connecte les unites interieures et exterieures, liberez l'air et l'humidite contenus dans le circuit de refrigeration au moyen d'une pompe a vide, comme cela est represente ci-dessous.
Need help?
Do you have a question about the FA SELECT FSHSR09B1C and is the answer not in the manual?
Questions and answers