SereneLife PYLE SLPAC12 / SLPAC12.5 Manual
Visit Our Website
![]()
SCAN ME
serenelifehome.com
Features
- Lightweight & Portable A/C Unit
- Compact Freestanding Room Air Conditioner
- (3) Operation Modes: AC Cooling / Dehumidifier / Fan
- Hassle-Free Room Cooling, Quick Setup
- Simple Electric Plug-in Operation
- Temp Control Air Circulator Function
- Automatic Swing Mode: Moving Wind Vents for Air Circulation
- Convenient Wide-Area Climate Control Room AC Coverage
- Digital Touch Button Control Panel with LED Display
- Time, Temperature & Fan Speed Adjustment Settings
- Includes Universal Window Mount AC Exhaust Kit
- Removable & Washable Air Filter Screen
- Modern Style, Sleek Body Housing
- Energy Efficient: Low Power Consumption
- Low Noise Level Motor
- Rolling Wheels for Easy Portability
- Used for Home, Office, School & Business Rooms
What's in the Box
- AC Unit
- Exhaust Hose
- Window Installation Plate
- Digital Remote Control
Technical Specs
- AC Cooling Power: 12,000 BTU
- Rated Power: 1150 Watt
- Coverage Area: Cools Rooms Up to 325'+ Square Feet
- Air Flow: 360 Cubic Meters / Hour
- Operating Modes: AC Cool / Fan / Dry (Dehumidifier)
- Dehumidifier Performance / Moisture Removal: 1.8 Liters / Hour
- Operating Noise Level: 56dBA (+/-3)
- Fan Speed Settings: Low/Medium/High
- Temperature Unit Selectable: °F / °C (Fahrenheit / Celsius)
- Adjustable Timer Settings: Up to 24 Hours
- Construction Material: Engineered ABS Housing
- Battery Operated Remote Control, Requires (2) x 'AAA' Batteries, Included
- Power Cable Length: 4.3' ft.
- Power Supply: 120V
- Total AC Dimensions (L x W x H): 17.4'' x 13.4'' x 32.1'' -inches
Important Safety Tips
Precautions
Please read the Manual carefully before operating the machine:
- This machine is for household use only.
- This machine is for indoor use only. Please place it in dry environment.
- Check power cord frequently. If power cord, plug or A/C is damaged, please don't operate. If the power cord is not long enough, power extension cable can be used. Cable should not scatter at places where power cord may be pulled out or people may be stumbled.
- The A/C should be away from heat source and avoid direct sunlight.
- Turn off the A/C before unplugging.
- Turn off and unplug the A/C before removing or cleaning it, or replacing its parts or when it is not used.
- Clean the A/C according to the Manual.
- Voltage of the A/C should meet requirements.
- Any damage incurred by incorrect power isn't included in the warranty.
- Children are not allowed to play with the A/C.
- This appliance is not intended for use by children, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Don't insert your fingers or any hard object to wind guide bar of the air outlet.
- Don't place the A/C at any place with water or other liquid.
- Prevent water or liquid from entering the A/C.
- Don't repair the A/C by yourself. Any possible hazard incurred by maintenance of laypeople will violate the warranty. If the supply cord is damaged, it must be replaced by professional maintenance personnel.
- Please use the accessories provided by the A/C manufacturer; otherwise, the A/C may be damaged.
- Cleaning and user maintenance shall not be made by children without supervision.
READ ALL INSTRUCTIONS BEFORE USE
Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance.
Always read and follow all safety messages.
![]()
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant leaks and comes into contact with an external ignition source, there is a risk of fire.
![]()
This symbol indicates that the operation manual should be read carefully.
![]()
This symbol indicates that service personnel should handle this equipment with reference to the installation manual.
This symbol indicates that information is available, such as the operating manual or installation manual.
REFRIGERANT (FOR R32 ONLY)
![]()
CAUTION ON FIRE
READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE.
R32 refrigerant gas complies with international environmental directives.
![]()
- Do not use methods to accelerate the defrosting process or cleaning other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (e.g., open flames, operating gas appliances, or operating electric heaters).
- Do not pierce or burn the appliance.
- Be aware that refrigerants may not contain an odor. The instructions should contain the following information:
- Piping material, pipe routing, and installation should include protection from physical damage during operation and service, and comply with national and local codes and standards, such as ASHRAE 15, IAPMO Uniform Mechanical Code, ICC International Mechanical Code, or CSA B52.
- All field joints shall be accessible for inspection prior to being covered or enclosed.
- The installation of pipework should be kept to a minimum.
- Provisions should be made for expansion and contraction of long runs of piping. Protection devices, piping, and fittings should be protected against adverse environmental effects (e.g., the risk of water collecting and freezing in relief pipes or the accumulation of dirt and debris).
- The piping in refrigeration systems should be designed and installed to minimize the likelihood of hydraulic shock damaging the system.
- Steel pipes and components should be protected against corrosion with a rustproof coating before applying any insulation.
- Flexible pipe elements should be protected against mechanical damage, excessive stress by torsion, or other forces, and should be checked for mechanical damage annually.
- Precautions should be taken to avoid excessive vibration or pulsation.
When using the product:
- Keep any required ventilation openings clear of obstructions.
- Servicing should be performed only as recommended by the manufacturer.
Unventilated Area
- An unventilated area where the appliance using flammable refrigerants is installed should be constructed so that, in case of a refrigerant leak, it will not stagnate and create a fire or explosion hazard.
- The non-fixed appliance should be stored in an area where the size corresponds to the room area specified for operation.
- The non-fixed appliance should be stored in a room without continuously operating open flames or other potential ignition sources.
- The manufacturer should specify any other continuously operating sources known to cause ignition of the refrigerant used.
- The appliance should be stored in a manner that prevents mechanical damage.
- Non-duct connected appliances containing A2L refrigerants with air openings in the conditioned space may have the body of the appliance installed in open areas such as false ceilings (not used as return air plenums), as long as the conditioned air does not directly communicate with the air in the false ceiling.
Qualification of Workers
- All operators or refrigeration circuit maintenance personnel should obtain a valid certificate issued by an industry-recognized evaluation agency to demonstrate that they have the qualifications to safely handle refrigerants, as required by the industry-recognized evaluation scope.
- Perform equipment maintenance and repairs only in accordance with the methods recommended by the appliance manufacturer. If another professional is required to assist in maintenance and repairs, it should be carried out under the supervision of personnel qualified to handle flammable refrigerants.
Special Warning:
![warning]()
- Place the A/C on even ground and install it vertically, so as to ensure normal operation of the compressor.
- The A/C should be at least 50cm away from surrounding objects. Keep air inlet and outlet smooth.
- Don't use the A/C beside gasoline or any other inflammable liquid.
- Don't use spraying agent and other solvent or flammable substances near the A/C; otherwise, its plastic may deform and electric parts may be damaged.
Power
- The plug should be in good condition and can't be damaged. Don't replace the plug with power plug.
- In order to run the A/C, plug the power cord first, and then press the power key.
- Place unit in upright position for 2 hours before turning on for first time.
Product Introduction
MAIN PARTS AND COMPONENTS
![Pyle - PYLE SLPAC12 - MAIN PARTS AND COMPONENTS MAIN PARTS AND COMPONENTS]()
- Handle
- Air inlet (L)
- Control panel
- Wind guide vent
- Caster
- Remote controller
- Air inlet (R)
- Air outlet
- Dehumidification drainage nozzle
- Air inlet grille
- Exhaust duct assembly
- Window sealing plate assembly
Control Panel and Remote Controller
![Pyle - PYLE SLPAC12 - Control Panel Overview Control Panel Overview]()
![Pyle - PYLE SLPAC12 - Remote control overview Remote control overview]()
- Power key
Press the key to turn ON/OFF the A/C. - Swing key
Press this key at any time after turning on the A/C to swing the wind guide bar automatically. - Speed key
Press the key to choose high/middle /low gear wind speed. - Temperature/ Time Adjusting key
Press the key at cooling mode to increase /reduce the setting temperature; press it at timing mode to adjust timing ON/OFF time; press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature. - Mode key
Press the key to choose cooling, fan, dehumidication - Timer key
Press the key at standby mode to set ON time. Press this key at ON mode to set OFF time. - Temperature/ Time Display Window
This window displays the adjusted temperature and time. - Remote controller receiving window
This window is used to receive signal of the remote controller. - °C/°F switching key: Press the key to switch °C and °F
Product Operation
Placement and Installation
Placement
Place it at even and dry place, and keep it at least 50cm. away from its surrounding object.
![Pyle - PYLE SLPAC12 - Product Operation - Placement Product Operation - Placement]()
Installation
- Screw the exhaust duct assembly in the air outlet behind the panel (counterclockwise).
![Pyle - PYLE SLPAC12 - Product Operation - Installation - Step 1 Product Operation - Installation - Step 1]()
- Insert the air exhaust hose into the window sealing plate, adjust opening width of window so that the window can match with the sealing plate properly; length of the sealing plate is adjustable.
![Pyle - PYLE SLPAC12 - Product Operation - Installation - Step 2 Product Operation - Installation - Step 2]()
Incorrect Installation
- It's important to keep the exhaust duct smooth. Incorrect installation will affect work of the A/C.
- Prevent the exhaust duct from sharp bending.
- Ensure air can flow smoothly in the duct.
![]()
The exhaust duct is designed especially for this model. Don't replace or lengthen it; otherwise, it will result in failure.
![]()
Notice: Max. developed length of the exhaust duct is 1,500mm. It's better to shorten it while in use and keep it horizontal while installation.
OPERATION METHOD
Cooling Mode
- When the A/C enters cooling mode automatically or cooling mode is selected after power ON, the cooling indicator lamp lights up.
- Press Up/Down key to adjust setting temperature (16°C~30°C)(60°F~86°F).
- Press Speed key to choose High/Mid/Low speed.
Fan Mode
- When pressing mode key or choosing Fan mode by pressing the remote controller, the wind indicator lamp lights up.
- Press Speed key to choose High/Mid/Low speed.
- Temperature can't be set.
Dehumidification Mode
![]()
- When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.
- Remove the dehumidification water wedge, insert water manifold, place the other end of the water manifold into the water vessel or drainage passage, as shown in the right figure.
- After entering the dehumidification mode, if room tempearture ≥17°C (62°F), the compressor is ON. Then control as follows: when room temperature ≤15°C (59°F), the compressor is OFF; when temperature increases to room temperature ≥17°C (62°F), the compressor will start again (in order to protect the compressor, it will be restarted 3min. later).
- In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can't be adjusted. Temperature can't be set.
Timer Mode
- In standby state, press the Timer key to set ON time. Press Up and Down keys to set ON time (1~24H), and the timer indicator lamp lights up.
- In ON state, pressure the timer key to set OFF time. Press Up and Down keys to set OFF time (1~24H), and the timer indicator lamp lights up.
Clean and Maintenance
DRAINAGE METHOD
This product is equipped with automatic water vaporization system. The condenser is cooled with the circulating of condensing water, so as to improve cooling efficiency and save energy.
![]()
- If the internal vessel is full of water, the display screen will display "FL", and the compressor stops working automatically. After power off, unscrew the water cover, pull out the water plug to drain of water, and it will become normal after being restarted.
MAINTENANCE
Notice: In order to avoid electric shock, please turn o the A/C and unplug before maintenance or repair.
CLEANING
- Unplug before cleaning.
- Wipe with soft semi-dry cloth. Don't use chemical reagent, such as benzene, alcohol and gasoline etc; otherwise surface of the A/C and even the whole A/C will be damaged.
- Prevent water from spattering in the A/C.
FILTER SCREEN
![Pyle - PYLE SLPAC12 - FILTER SCREEN cleaning FILTER SCREEN cleaning]()
- Vacuum the filter screen once every two weeks. If it is blocked by dust, efficiency of the A/C will be reduced.
- Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures. Use vacuum to remove lint from filters.
- Put the filter screen into the warm water (about 40°C or 104°F) added with neutral detergent, dry it at a shady place after cleaning.
If the filter is dirty, clean it in warm water (about 40°C/ 104°F) with a neutral detergent.
If the filter is not very dirty, you can clean off the dust using a vacuum cleaner.
SEASONAL CLEANING I
f the A/C will not be used for a long time:
- Pull out the water plug to drain.
- Run the A/C in fan mode for 2H till the inside is dry.
- Turn off the A/C and unplug.
- Wash the filter screen and reassemble it.
- Dismantle the exhaust duct and keep it properly.
- Cover the A/C with a plastic bag and place it at a dry place.
Common Failures and Diagnosis
Intelligent Error Detection
Error-detecting code | Multi-functional defection |
E1 | Error of the coil's temperature sensor |
E2 | Error of indoor temperature sensor |
E4 | Anti-freezing protection: temperature of the coil is too low and the whole A/C is off. When temperature excesses 8°C or 46.4°F, the protection is released and previous working state is recovered. |
FUSE PARAMETERS
- Voltage: 250VAC
- Current: 3.15A
Troubleshooting
In case of any of the following trouble, please contact professional maintenance personnel in time.
Trouble | Cause | Solution |
The A/C doesn't work | No display | Reset the circuit breaker on the A/C cord |
The display panel shows "FL" | Restart the A/C after powering off and draining; it will normalize |
The Time OFF function is started | The A/C can be restarted 3 min. after being turned off |
The A/C starts frequently | Direct sunlight | Close the curtains |
Open doors and windows or too many people/heat sources in the room | Close doors and windows, remove heat sources |
Filter screen is very dirty | Clean or replace the filter screen |
Air inlet or outlet is blocked | Remove the obstruction |
Big noise from the A/C | The A/C is placed unevenly | Place the unit on even, firm ground to prevent shaking |
The compressor doesn't work | Delay protection activated | Wait for 3 minutes for the temperature to decrease, then turn on again |
Notice: When there is any abnormal to the A/C, turn it off and unplug, and then contact professional maintenance personnel.
The above technical parameters are subject to change without notice.
Register Product
Thank you for choosing SereneLife. By registering your product, you ensure that you receive the full benefits of our exclusive warranty and personalized customer support.
Complete the form to access expert support and to keep your SereneLife purchase in perfect condition.
![]()
Serenelifehome.com/pages/register
Questions or Comments?
We are here to help!
Phone: 1.718.535.1800
Serenelifehome.com/ContactUs
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download SereneLife PYLE SLPAC12 / SLPAC12.5 Manual
Need help?
Do you have a question about the PYLE SLPAC12 and is the answer not in the manual?
Questions and answers