Important information
The product must be installed by a qualified Gas Network RGI (Registered Gas Installer).
The product has been independently tested and certified by an ISO 17025 and ISO 17065 accredited
laboratory.
The product has been tested to work within these temperatures: -20 °C to +50 °C.
Warranty: 5 years from installation
The product must only be installed in domestic premises and with compatible ECV type (see table).
The product is only suitable for indoor installations.
Do not install if the product appears to be damaged in any way.
Do not use any cleaning chemicals on any part of this product.
Do not spray product with oils or lubricants.
Do not over tighten threads.
Warning: Only press 'STOP' button when attached to a compatible ECV.
EasyAssist® Remote is a thermally activated
shut-off device (DIN 3586:2003). The thermal fuse
activates at +57 °C, triggering the mechanism to
close the ECV.
The thermal fuse is visible through a viewing window
on the Button as shown:
Check the thermal fuse is in place and intact on installation.
If missing or damaged the EasyAssist® Remote cannot be used and must be replaced.
The box contains
Tools and fixings required
Flathead screwdriver
Pozi screwdriver (PZ1)
12 mm or 13 mm Socket or Nut driver (to fit M8 Handle-Nut) - size dependent on ECV type
10 mm Spanner
2.5 mm Hex key
Drill, 5mm drill bit and appropriate hardware for wall mounting or [OPD-0014060] mounting bracket kit
Viewing window
Thermal fuse
EasyAssist® Remote cap
(with captive screws)
EasyAssist® Remote unit
Button
User label
Operating label
Button
spacer
Bend radius template (included in packaging)
Compatible ECV types
This product may only be used with the following
GIS-V7-3:2014 ECV products:
DESCRIPTION
3/4" BSPT FEMALE x
3/4" BS746 MALE STRAIGHT
3/4" BSPT FEMALE x
3/4" BS746 MALE STRAIGHT
Product information
EasyAssist® Remote is a trademark of
Oxford Gas Products Limited © 2023-24.
All rights reserved.
Patents: Granted patent GB2592068 and
GB2613329, with patents pending in other
jurisdictions, registered designs.
FIXINGS
This product is manufactured by
EasyAssist® Remote
locking screw
Continental Product Engineering Limited under
(Continental ECV)
license from Oxford Gas Products Limited.
EasyAssist® Remote
Designed in Oxford, UK
locking screw
(Sperryn ECV)
Assembled in Norfolk, UK
Slotted nut
Mounting screws
Wall plugs
Cable ties
Adhesive cable tie pads
Alcohol wipe
Manufacturer details
CONTINENTAL PRODUCT ENGINEERING LIMITED
Prospect House, Little Money Road,
Loddon Business Park
Norwich, Norfolk, NR14 6JD, UK
Tel: +44 (0)1508 522400
www.continental-uk.com
OPERATING
MANUFACTURER
PRESSURE
PART NO.
CONTINENTAL
LOW
BV34X34FSLP
SPERRYN
LOW
F8325KS

Advertisement

loading
Need help?

Need help?

Do you have a question about the EasyAssist REMOTE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oxford EasyAssist REMOTE

  • Page 1 Check the thermal fuse is in place and intact on installation. If missing or damaged the EasyAssist® Remote cannot be used and must be replaced. EasyAssist® Remote is a trademark of Oxford Gas Products Limited © 2023-24. All rights reserved. The box contains...
  • Page 2 EasyAssist® Remote Installation | Standard orientation Remove the ECV locking screw and replace with the EasyAssist® Remote locking screw. For Continental ECV use the hex drive locking Turn off gas by rotating the Emergency Control screw and for Sperryn ECV the slotted drive Valve (ECV) handle 90 degrees anti-clockwise.
  • Page 3 Button installation | Using wall fixings (mounting onto wood, plasterboard, masonry) TEMPLATE Identify location to mount the EasyAssist® Remote button, no more than 1 meter from the ECV, with the button orientated so the ‘STOP’ is horizontal and ensuring that the cable: •...
  • Page 4 EasyAssist® Remote | Cable adjustment Locking nut Adjuster Next, holding the cable to prevent twisting, screw Push the lever up to switch on the gas, pull the the adjuster all the way in until the locking nut lever down to switch the gas back off. To adjust the cable, using a 10 mm spanner, touches the underside of the Button Housing.