Whitehall WHF-260-S User Manual

Full-immersion models whirlpool

Advertisement

Quick Links

User Manual
Full-Immersion Models
WHF-260-S, WHF-270-S, WHF-300-S, WHF-425-S
WHF-260-S
WHF-425-S
P.O. Box 3527
• City of Industry, CA 91744-0527 U.S.A.
800-591-9280
• 626-968-6681 •
www.whitehallmfg.com
6900-254-001_REV_A
Revised: 10-14-2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WHF-260-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Whitehall WHF-260-S

  • Page 1 User Manual Full-Immersion Models WHF-260-S, WHF-270-S, WHF-300-S, WHF-425-S WHF-260-S WHF-425-S P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A. 800-591-9280 • 626-968-6681 • www.whitehallmfg.com 6900-254-001_REV_A Revised: 10-14-2024...
  • Page 2 The information in this manual is proprietary and confidential to Whitehall Manufacturing, a division of Acorn Engineering and a member of Morris Group International. Any reproduction, dissemination or distribution of this document in whole or in part without prior written authorization of Whitehall Manufacturing is strictly prohibited. While every effort has been made to ensure the accuracy of information provided in this document, please note the information is subject to change without notice.
  • Page 3: Table Of Contents

    Operating Instructions.........................16 Draining Instructions ..........................16 Thermometer Calibration Instructions....................17 Disinfecting and Cleaning Instructions....................18 Turbine Maintenance ..........................19 Troubleshooting ..........................19 & 20 Classification ...............................21 Specifications...............................21 WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 4: Symbols

    Indicates that user manual shall be referred to before performing any installation, operation or maintenance Alternating Current Indicates alternating current is present Manufacturer Indicates manufacturer of device Manufacture Date Indicates manufacture date of device WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 5: Warnings

    • If there is visible damage to the Whirlpool or packaging upon receipt, report this damage to shipping company and Whitehall. Do not use the Whirlpool if damage to it is suspected. •...
  • Page 6: Incident Reporting

    Incident Reporting Any serious incident that has occurred in relation to the Whirlpool should be reported to Whitehall manufactur i ng. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 7: User Skills

    The user can enter the tub or be placed in the tub and is fully immersed in the water to the neck. A vinyl headrest is provided for the user. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 •...
  • Page 8: Accessories

    Vinyl Headrest Mount headrest tube in mount on tub and clamp in place with knob. For maintenance, see Disinfecting and Cleaning Instructions. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 9: Facility Requirements

    (for which CISPR 11 class B is normally required) this equipment might not offer adequate protection to radio-frequency communication services. The user might need to take mitigation measures, such as relocating or re-orienting the equipment. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 •...
  • Page 10: Rough-In For Whf-260-S

    ⑤ 31.8mm (1-¼ inch) NPT x plain end pipe tube ⑪ Thermometer filler connection ⑥ Drain valve lever handle * Customer provided WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 11: Rough-In For Whf-270-S

    Adjust leg length as indicated below to allow for proper drainage (assumes level floor): Leg Set Leg Length, cm (inches) 25.4 (10.00) 28.0 (10.625) 28.6 (11.25) 30.2 (11.875) 31.1 (12.25) WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 12: Rough-In For Whf-300-S

    ⑪ Removable grid strainer ⑥ 31.8 mm (1-¼ in) NPT x plain end pipe tube filler ⑫ Thermometer connection * Customer provided WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 13: Rough-In For Whf-425-S

    Adjust leg length as indicated below to allow for proper drainage (assumes level floor): Leg Set Leg Length, cm (inches) 25.4 (10.00) 28.0 (10.625) 28.6 (11.25) 30.2 (11.875) 31.1 (12.25) WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 14: Instructions

    Secure into position by tightening bearing bolt (9). M ove carriage assembly (1) around tub and readjust if necessary. 5. Engage friction lock (10) by rotating the lock handle (11) counterclockwise. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 •...
  • Page 15: Installing Turbine(S)

    (Figure 8) Loosen handle (4), insert headrest rod (2) into raising and lower assembly (3) and tighten handle (4). Figure 9: Installing thermometer Figure 8: Installing headrest WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 16: Operating Instructions

    Refer to Figure 6 and Figure 7. 1. Turn the turbine power switch (6) off. 2. Turn drain handle (1) to empty tub. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 •...
  • Page 17: Thermometer Calibration Instructions

    5. Re-calibration shall be performed at least every 12 months or as needed. Figure 10: Calibrating the thermometer WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 18: Disinfecting And Cleaning Instructions

    5. Ensure the pressure control valve is in the open position. 6. Turn on the turbine for 5 seconds and turn it off. Wait 10 minutes. WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 •...
  • Page 19: Turbine Maintenance

    Fuse Replacement Procedure: 1. Turn off and unplug the turbine WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 20 230V~ turbine (or equivalent) 5. Replace the fuse covers by pushing down and turning clockwise 6. Plug in the turbine WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 21: Classification

    5 - 95%, non-condensing Atmospheric Pressure 70 – 106 kPa Thermometer Range Dual scale: 5-60°C and 40-140°F Accuracy ± 1.1°C (2°F) WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A. Phone 800-591-9280 • 626-968-6681 • www.whitehallmfg.com...
  • Page 22 Stainless steel must be properly maintained after water has been introduced into the fixture, or Whitehall's limited warranty is void. If you have any questions or require technical assistance, please call 800-743-8219.

This manual is also suitable for:

Whf-270-sWhf-300-sWhf-425-s

Table of Contents