Download Print this page

Frigidaire FPIC3695MS Product Specifications page 3

36" induction built-in cooktop
Hide thumbs Also See for FPIC3695MS:

Advertisement

A - Width
36-3/4"
Product Cutout Dimensions
D - Width (min. - max.)
35-7/8" - 36"
Built-In Cooktop Specifications
Product Shipping Weight (approx.) – 58 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts = 10.8 / 9.4 kW
Amps @ 240 / 208 Volts = 45.2 / 45.0 Amps
Recommended Circuit Breaker – 40 Amps
Always consult local and national electric codes.
Cooktop cutout height includes clearance needed beneath cooktop to
allow for armored cable and installation of junction box on back wall.
Position center of junction box 10" inward from right side of cooktop
cutout, and 12" down from underside of countertop.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36-3/4".
Allow 30" minimum clearance between top of cooktop platform
and bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/8" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
Allow 2" minimum clearance between rear edge of cutout and nearest
combustible surface (or backsplash) above countertop.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
FPIC3695M 06/11
Product Dimensions
B - Depth
21-1/2"
E - Depth (min. - max.)
F - Height (min.)*
20-3/8" - 20-1/2"
1-800-FRIGIDAIRE
frigidaire.com
1-800-265-8352
frigidaire.ca
© 2011 Electrolux Home Products, Inc.
C - Height
G (min.)
4-3/8"
2"
K - Cabinet Opening Width
(min.)
4-1/2"
36-3/4"
Allow 7-1/2" minimum required clearance from left edge of cooktop
to nearest combustible wall and 7-1/2" minimum from right edge of
cooktop to nearest combustible wall.
Installation of drawer not recommended beneath cooktop.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Electric Built-In Cooktop model FPIC3695M is approved to be used
over any Frigidaire® Electric Single Wall Oven. (Refer to Electric
Cooktop Installation Over 30" / 27" Electric Single Wall Oven
Specifications page on web.)
Electric Built-In Cooktop model FPIC3695M is approved to be used
in combination with Frigidaire® 36" Downdraft Vent E36DD75ESS or
PL36DD50EC. (Refer to model-specific Downdraft Vent product page
on web for detailed countertop preparation specifications.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN # 903061-9010).
Built-In Cooktop
FPIC3695M S
36" Induction
Required Clearances
H (min.)
I (min.)
J (min.)
7-1/2"
7-1/2"
Utility Connection Locations
Power Supply
Right Rear
Accessories information available
on the web at frigidaire.com
subject to change.
Printed in the U.S.A.
2-1/2"
Specifications

Advertisement

loading