Page 1
54 is used to set up and configure operation. The safety interlock is wired directly to the A2MC controller on a dedicated circuit. On some A2MC’s the input is marked “ATC Sensor” and on others “Safety”. Refer to the pictures below. This sensor is normally “closed” or normally “on”...
Page 2
Machine A2MC Functions Press ON to enable/disable the interlock. • If set to OFF the interlock will be disabled. • If set to ON you can enter a delay for the interlock activation. Press DELAY and type in a delay for when the interlock becomes active once triggered. Consider how much time an operator will require to exit the safety device (mat, light curtain, cage etc) before the safety the circuit become active.
Page 3
There are three states of safety interlock. Safety Interlock: This is the input on the A2MC which detects the state of the safety mats or light curtains. Tripped State: This occurs when the safety mats have been stepped on or the light curtains have been interrupted.
Page 4
Machine A2MC Functions Operation When Machine Is Running a Job If the machine is running a job and the operator puts the safety system in the tripped state, then the following occurs: • The motion immediately stops. • The cutting positions are raised to the G0 Z safe height.