Labeling machine industry solutions Safety precautions The following marks are used in the safety-related contents of this instruction manual. The instructions on the safety marks are the main contents and must be followed. Please read the instruction manual carefully before use. The installation of components must be performed by professional technicians.
Y4~Y7, with independent acceleration and deceleration. The total transmission of high-speed counting + high-speed pulse cannot exceed 480KHz, CX3G-16MT, usually 8 channels of 10KHZ Can be specially encrypted. Setting the password to 12345678 can completely prohibit reading the program. [Note: PLC only supports 8-bit...
Labeling machine industry solutions password encryption] PLC programming compatible software GX Developer8.86Q and GXWorks2 32K step program capacity, 32K power-off retention registers, support interrupt, linear and circular interpolation, PID self-tuning and other functions Powerful functions. Compatible with FX3G/FX3U/FX3S series PLC, fast operation speed ...
Page 9
Labeling machine industry solutions Batch data and recipe import and export functions...
Labeling machine industry solutions 2.2. Wiring Definition name illustrate Input common terminal, need to connect to 24V Interrupt positioning by sensing tags Detect incoming materials and label them The emergency stop is normally closed and stops immediately after being pressed. The start button is a hold type, press it again to pop up and stop the device...
Page 17
Labeling machine industry solutions name illustrate COM0 The output common terminal of Y0~Y3 needs to be connected to 0V Send pulse to labeling driver, connect to negative pole of labeling driver pulse COM1 The output common terminal of Y4~Y7 needs to be connected to 0V Send pulse to the transmission driver and connect to the negative pole of the transmission driver pulse...
Labeling machine industry solutions Chapter 3 Function parameters 3.1. Startup interface This project was designed by Gumei Technology and adopted the calibration algorithm used in labeling. Higher precision, greatly optimizing the original labeling error caused by the mechanical structure ...
Page 22
Labeling machine industry solutions Labeling Touch to switch mode, divided into single label mode/dual label mode , mode label 1/2 sheets after detecting the material Current The name of the recipe currently in use. The switch button is to enter recipe the recipe configuration interface.
Labeling machine industry solutions Alarm Touch to enter the alarm record interface Record Total Record the total number of products produced production Identification After the automatic recognition is completed, the button will length automatically reset . The recognition length = label length + gap length Label The position where the next label stops after the current label is output location...
Labeling machine industry solutions Labeling axis The actual running speed of the labeling axis speed Conveyor shaft Actual running speed of the conveyor shaft speed Preventing After sensing the product, the product detection is triggered again delay within the parameter delay, and no bid is issued. Function You can choose whether the corresponding function will be Disable...
Page 25
Labeling machine industry solutions Label Detection The tag sensor sends a signal to the PLC. When the tag is sensed, the signal is ON. Product Testing The product sensor sends a signal to the PLC, and when it senses the product, the signal is ON Emergency Motor speed, display the current motor speed Stop...
Labeling machine industry solutions Labeling PLC gives direction signal to labeling drive direction Conveying PLC gives direction signal to conveyor drive direction Running lights When the equipment is running normally and automatically, the running light is on. 3.5. Parameter interface 1 pulse Breakdown of Drive Settings 1 turn lead...
Labeling machine industry solutions rotation Acceleration Corresponding axis acceleration and deceleration settings deceleration axis A button designed to facilitate the measurement of one-circle lead. rotation It can be operated after setting one-circle pulse. 3.6. Recipe pop-up Indicator The corresponding indicator light will light up green for the recipe Lights currently being used.
Labeling machine industry solutions Recipe The name of the recipe, supports Chinese editing and display Name Speed The running speed of the label axis is only displayed. In fact, all the display required parameters have been saved. Recipe Save all current parameters in the corresponding recipe Saving Recipe Download all the data of the selected recipe and use it for production...
Labeling machine industry solutions information displayed at the top. Each alarm displays the corresponding trigger time and recovery time 3.8. Emergency stop screen The emergency stop button triggers this pop-up screen, prohibiting operations and production actions Reset the automatic process, and restart after emergency stop and recovery, and the action will start again ...
Labeling machine industry solutions Describe the specific meaning and usage of each parameter The help interface entered in each working interface is the corresponding parameter analysis description 3.10. Lock screen...
Page 33
Labeling machine industry solutions Usage: There are 6 phases in total. Enter the phase setting interface: Set the expiration date and turn on the button for each issue separately as needed. After setting, click Confirm. You need to confirm the settings every time you enter the installment setting interface, otherwise the installment will not work.
Labeling machine industry solutions Chapter 4 Alarm query Serial Alarm Name belong Solution number Automatically Status Currently in automatic mode running display Status Manual operation Currently in manual mode display The labeling motor is running manually 1: The labeling motor is not running. Check the debugging interface: Is the labeling Manual labeling Status...
Page 35
Labeling machine industry solutions 3: If the motor still does not move, check whether the PLC is in operation. The total number of products is being cleared and will automatically reset after Status Product clearing completion display 1: Not reset, check whether the PLC is running normally Label length identification in progress, will automatically reset after completion...
Page 36
Labeling machine industry solutions whether the tag sensor is normal. 2: The motor does not move: Check whether all parameters of the label axis are The labeling axis rotates one circle and automatically resets after completion 1: When the motor is not reset, press the emergency stop button in time to check Labeling axis Status...
Page 37
Labeling machine industry solutions operating normally. The labeling axis is not operated in Automatic mode Status automatic mode stops the labeling display To enable, you need to switch on the motor! function disable in the debug interface Stopping the The conveyor axis is not moved in conveying motor Status automatic mode...
Page 38
Labeling machine industry solutions alarm alarm between PLC and HMI to see if they match. Note: If the "abnormal alarm, system alarm " alarm is not cleared after operation, please contact the manufacturer!!!
Labeling machine industry solutions Chapter 5 Networking Communications The programmable controller comes with two PLC programming ports: Mini B USB port (faster download and read speed) and RS232 (8-hole mouse head female socket), conventional 2 RS485, optional RS232 communication port; optional CAN bus.
Need help?
Do you have a question about the CX3G-16MT and is the answer not in the manual?
Questions and answers