Wireless Footswitch
User Manual
10 746 233 version 02
Date of issue: 2024-11-28

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Wireless Footswitch and is the answer not in the manual?

Questions and answers

Summary of Contents for Leica Microsystems Wireless Footswitch

  • Page 1 From Eye to Insight Wireless Footswitch User Manual 10 746 233 version 02 Date of issue: 2024-11-28...
  • Page 2 The information provided by this manual is directly related to the operation of the equipment.Medical decisions remain the responsibility of the clinician. Leica Microsystems has made every effort to provide a complete and clear user manual highlighting the key areas of product use. Should additional information regarding the use of the product be required, please contact your local Leica representative.
  • Page 3: Table Of Contents

    Table 6 in accordance with IEC 60601-1-2 Care and Maintenance Cleaning and disinfection Maintenance and repair Battery storage Disposal Technical Data Wireless Footswitch Electrical data Wireless specifications Ambient conditions Standards Limitations of use Leica Wireless Footswitch / Ref. 10 746 233 / Version 02...
  • Page 4: Introduction

    Action required; this symbol indicates that you need to perform a specific action or series of actions. Leica Wireless footswitch / Ref. 10 746 233 / Version 02...
  • Page 5: Safety Notes

    The effect of the Wireless Footswitch on other instruments has • The Wireless Footswitch may be used only in closed rooms and been tested as specified in IEC 60601-1-2. The system passed must be placed on a solid floor.
  • Page 6: Dangers Of Use

    (21) - Serial number CE Mark Type label CSA certification mark FCC mark WEEE label - Do not dispose of electrical or electronic devices along with normal domestic waste. China RoHS label Leica Wireless footswitch / Ref. 10 746 233 / Version 02...
  • Page 7: Function And Design

    A signal is transmitted from the transmitter unit on an incline of more than 35°. To release the automatic in the Wireless Footswitch to the receiver unit on the control unit. safety function, press a control element twice on the The standard configuration of the pedals and switches can be Wireless Footswitch.
  • Page 8: Operation

    Marking the Wireless Footswitch and receiver unit The Wireless Footswitch and its receiver unit are marked before use to uniquely define pairs of equipment and prevent a mix-up. Affix the provided sticker (1) to the receiver unit (2) or the stand.
  • Page 9: Connecting The Receiver Unit Of The Wireless Footswitch

    Check the user presets on the control unit of your Leica Surgical compartment. Microscope. Test all functions of the Wireless Footswitch. (Control unit of the Emergency cable (optional) Leica Surgical Microscope.) If the batteries fail, the optional emergency cable can be used to Replacing batteries ensure that the power supply is working.
  • Page 10: Manufacturer's Declaration Of Electromagnetic Compatibility (Emc)

    Table 1 in accordance with IEC 60601-1-2 Guidance and manufacturer's declaration - electromagnetic emissions The Wireless Footswitch is intended for use in the electromagnetic environment specified below. The customer or the user of the Wireless Footswitch should ensure that it is used in such an environment.
  • Page 11 Table 2 in accordance with IEC 60601-1-2 Guidance and manufacturer's declaration - electromagnetic immunity The Wireless Footswitch is intended for use in the electromagnetic environment specified below. The customer or the user of the Wireless Footswitch should ensure that it is used in such an environment.
  • Page 12 Table 4 in accordance with IEC 60601-1-2 Guidance and manufacturer's declaration - electromagnetic immunity The Wireless Footswitch is intended for use in the electromagnetic environment specified below. The customer or the user of the Wireless Footswitch should ensure that it is used in such an environment.
  • Page 13 The Wireless Footswitch may not be used in direct proximity of other instruments. If it is necessary to operate them in the vicinity of other instruments, the microscopes should be monitored to ensure that they function properly in this arrangement...
  • Page 14: Care And Maintenance

    The unit packaging is to be recycled. Befor cleaning, switch off your Leica cireless Footswitch. The Wireless Footswitch must be cleaned after each clinical use to prevent instrument malfunctions due to dirt and bacteria. When using detergents and disinfectants, you must comply with the general regulations for personal protection.
  • Page 15: Technical Data

    Modulation 2-FSK; MSK Compliance Europe EN 300440 - EN 301489 FCC, Part 15C, single modular - FCC identifier: XK5-SW100AMBINT (footswitch) XK5-SW100AMBEXT (receiver) Canada RSS-210 Issue 7, - IC identifier: 5158A-SW100AMBINT (footswitch) 5158A-SW100AMBEXT (receiver) Leica Wireless Footswitch / Ref. 10 746 233 / Version 02...
  • Page 16 Technical Data Leica Wireless footswitch / Ref. 10 746 233 / Version 02...