Page 1
NAME Impala Ref: PRJ30654 EN Electric Towel Warmer Flomasta EN IMPORTANT - These instructions are for your safety. Please read through them thoroughly prior to handling the product and retain them for future reference. This product is only suitable for well insulated spaces or occasional use.
Page 2
EN Parts 02. x4 03. x4 04. x4 Ø8 x 64 mm ST4.8 x 60 mm 07. x4 08. x4 05. x4 06. x4 M5 x 12 mm M6 x 20 mm 01. x1 EN You will need 8 mm EN Contents Safety Guarantee...
EN Safety Before you start • Read these important instructions carefully before using the appliance. • Keep these instructions during all the appliance’s lifespan for future reference. • Always give these instructions to anyone who will use the appliance, even if it’s transferred to a third party. Safety •...
Page 4
WARNING: IN ORDER TO AVOID A HAZARD FOR VERY YOUNG CHILDREN, THIS APPLIANCE SHOULD BE INSTALLED SO THAT THE LOWEST HEATED RAIL IS AT LEAST 600 MM ABOVE THE FLOOR. • The appliance is to be installed so that switches and other controls cannot be touched by a person in the bath or shower.
Page 5
WARNING: TO REDUCE THE RISK OF FIRE, KEEP TEXTILES, CURTAINS, OR ANY OTHER FLAMMABLE MATERIAL A MINIMUM DISTANCE OF 1 M FROM THE AIR OUTLET. • The appliance is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
Page 6
CAUTION: BEFORE ACCESSING THE CONNECTION TERMINALS, ALL ELECTRIC SUPPLY CIRCUITS MUST BE DISCONNECTED. • Please ensure that the appliance rated power is lower than the power managed by your home installation socket outlet. WARNING: IF THE POWER CABLE BECOMES VERY HOT, IT MEANS YOUR HOME INSTALLATION IS NOT ABLE TO MANAGE THE APPLIANCE RATED POWER.
Page 7
• Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Page 8
CAUTION: ANY PRODUCT INTERVENTION AND / OR REPAIR BY THE USER OR A NON- PROFESSIONAL THIRD PARTY MAY JEOPARDIZE THE SAFETY OF PERSONS AND PROPERTY. SO, DO NOT ATTEMPT TO DISASSEMBLE THIS APPLIANCE, REPAIR IT OR PERFORM ANY MODIFICATIONS BY YOURSELF. WARNING: DEFECTS AND THEIR CONSEQUENCES RESULTING FROM PRODUCT INTERVENTIONS AND / OR REPAIRS CARRIED...
CAUTION: THE USE OF AN ELECTRIC CONNECTION TERMINAL BLOCK TO SCREW (DOMINO) IS NOT CONSIDERED AS A SAFE CONNECTION METHOD ANYMORE. • These indicative codes and colours have to correspond to the supply mains terminals and wires in your electric supply mains. •...
This symbol is known as the ‘Crossed-out Wheelie Bin Symbol’. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical / electronic products or batteries can be harmful to health and the environment.
Page 11
EN Preparation min 15 cm min 60 cm EN Installation 01. x1 5059340987132_MNL_IN_V03.indb 11 5059340987132_MNL_IN_V03.indb 11 7/5/2024 10:02:54 AM 7/5/2024 10:02:54 AM...
Page 12
08. x4 06. x4 M6 x 20 mm W1 (mm) W2 (mm) H1 (mm) H2 (mm) 02. x4 03. x4 Ø8 x 64 mm ST4.8 x 60 mm 04. x4 05. x4 65 mm 03 05 5059340987132_MNL_IN_V03.indb 12 5059340987132_MNL_IN_V03.indb 12 7/5/2024 10:02:55 AM 7/5/2024 10:02:55 AM...
Page 13
07. x4 M5 x 12 mm DANGER: Risk of appliance unhooking! The wall mount fasteners (Plastic plugs and metal screws) included with the appliance are only scheduled for an installation on a concrete wall. WARNING: For wood walls, cinder blocks, plasterboard or other wall types, consult a professional to know what is the best attachment method as the supplied wall mount fasteners will not be suitable.
Page 14
These areas determine the installation of wall mounted electrical appliances. Volumes are divided between: • Volume 0: Water receiving area • Volume 1: Volume 0 + Up to a height of 2.25 m above the ground. For Italian showers: 1.2 m radius length from the showerhead.
Page 15
EN Use Symbol Function Symbol Function Power button Comfort mode Menu Economy mode Boost Programming mode Anti-freeze detection Down Child lock Boost mode Heating Open window detection Daily program On / Stand-by mode Short press: Select on or stand-by mode Press and hold 6 seconds: Reset and restore the appliance to initial factory setting for all settings made and saved.
Page 16
The default clock and day are , monday noon. In on mode: Short press: Change the heating modes or access to the 24/7 programming mode. • Comfort mode, icon : Short press or press and hold on to set the room temperature from 07 to 30 °C, 0,5 °C by 0,5 °C.
Page 17
If no action is made, the appliance launch the 24/7 programming with factory preset programs. The Comfort and Eco room temperatures are alternatively used in the 24/7 programming. Always ensure Comfort and Eco temperatures are correct according to your preference prior to use the 24/7 programming.
Page 18
In stand- by or on mode: • Short press to activate the timer mode. The default timer time is 00:30 hour. • Short press or press and hold to set the timer time from 00:00 to 24:00, settings possibilities every 15 mins. In this mode, the thermostat temperature us automatically set at 30 °C.
Page 19
In stand- by mode: Press and hold 3 seconds: Access to the temperature compensation setting Short press or press and hold on to adjust the temperature compensation from -8 to 8 °C. Setting °C by °C. The default temperature compensation is -2 °C. Then temperature compensation setting is useful to calibrate the appliance according to your room if you notice the appliance temperature set in the different heating modes is not coherent compared to the real room temperature.
Page 20
Information requirements for electric local space heaters Model identifier(s) GDFL500-03B / GDFL500-03W Item Symbol Value Unit Heat output Nominal heat output 0.300 Minimum heat output (indicative) N.A. Maximum continuous heat output 0.300 max, c Auxiliary electricity consumption At nominal heat output At minimum heat output In standby mode Item...
Troubleshooting Operation of your appliance can lead to errors and malfunctions. The following tables contain possible causes and tips to resolve them. Please consult this table before to contact after sales service. Trouble Possible causes Solution Connect the appliance to the electric mains including a earth connection.
Page 22
EN Care & maintenance • Any intervention linked to the appliance cleaning, servicing or maintenance must be carried out with the appliance disconnected from the electric mains and cool down. • Clean regularly the appliance, every quarter maximum, with a soft non-abrasive dust cloth microfiber type. •...