Becker C16 PLUS Series Assembly And Operating Instructions Manual

Sun protection drive with integrated radio transceiver for locking system
Table of Contents

Advertisement

Quick Links

R8-17...L120-11
Model: C16 PLUS
Assembly and Operating Instructions
en
Sun protection drive with integrated radio
transceiver for locking systems
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 301 418 0     16/12/2024    
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
info@becker-antriebe.com
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C16 PLUS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Becker C16 PLUS Series

  • Page 1 Sun protection drive with integrated radio transceiver for locking systems Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2010 301 418 0     16/12/2024     Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany info@becker-antriebe.com www.becker-antriebe.com...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembly ....................................  7 Explanation of functions ...............................  9 Commissioning with a CentronicPLUS transmitter ........................
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • Optimised for sun protection applications with locking system • freely programmable locking and unlocking limit position • Automatic detection of upper limit position • Several drives can be operated in parallel •...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
  • Page 5 • If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones, safety areas), compliance with all applicable regulations and standards must be ensured. • Once the drive has been installed, the fitter must mark the used tubular drive in the “Technical data” chapter and make a note of the installation position.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of sun protection systems with locking systems . To function properly, these tubular drives need a fixed stop in the upper limit position (retracted blind). It may only be used in networked systems if all the individual drives are exactly synchronised and reach the limit positions at the same time.
  • Page 7: Assembly

    Assembly Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
  • Page 8 For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft.
  • Page 9: Explanation Of Functions

    Explanation of functions Explanation of symbols Ascend / retract Descend / extend Ascend / retract disabled Descend / extend disabled Centronic: The drive stops after releasing the respective travel button Centronic PLUS: The drive stops 5 s after pressing the respective travel button Wind Wind threshold value Sun threshold value...
  • Page 10: Commissioning With A Centronicplus Transmitter

    Commissioning with a CentronicPLUS transmitter Explanation of symbols UP button STOP button DOWN button Programming button (on the transmitter) Function button (on the transmitter) LED ring on the transmitter Receiver confirms once or multiple times by “clicking” or “shifting” 1 = direction switch 2 = radio switch Unlocked Locked...
  • Page 11: Establish Programming Mode

    Connecting the tubular drive Connect the tubular drive to the power supply. 230V AC / 50 Hz 1 = blue 3 = black 2 = brown 4 = green / yellow Switch on the power. ► The tubular drive confirms. Establish programming mode This step is only necessary if one of the devices to be programmed is not yet part of the in- stallation.
  • Page 12: Programming The Centronicplus Transmitter

    Programming the CentronicPLUS transmitter With brand new products, devices from another installation or products that have been re- stored to factory settings, programming mode must be established beforehand (see Es- tablishing programming mode). Bring the transmitter as close as possible to the receiver to be programmed. Press the programming button for 3 seconds when it is ready to program.
  • Page 13: Selection Of The Receiver For The Setting Mode

    Now press and hold the programming button for a new transmitter. ▻ After 5 seconds, the LED rings on both transmitters start to fill in green. Continue pressing and holding the programming button. ▻ Once the new transmitter has been added successfully, both transmitters flash green to confirm.
  • Page 14: Checking That The Running Direction Is Correct

    Checking that the running direction is correct The direction of rotation can only be changed if no limit position has been set. There are several ways to change the direction of rotation: • Changing direction of rotation via the direction switch •...
  • Page 15: Setting The Limit Positions

    Setting the limit positions Attention The tubular drives are designed for short-time operation (for the operating mode, please see technical data). An inbuilt thermal protection switch prevents overheating of the tubu- lar drive. During commissioning (long drop distance or long running time), the ther- moswitch may trigger.
  • Page 16: Deleting The Limit Positions

    Deleting the limit positions Attention When the limit positions are deleted, all the other set functions (intermediate position I, in- termediate position II) are deleted as well. Any additional functions that may have been set are deleted at the same time, or are reset to the factory default settings.
  • Page 17 Travelling to the desired intermediate position Press the travel button for the desired intermediate position twice within one second. ▻ The transmitter confirms with a rotational movement of the LED ring from blue to turquoise. ► The shading solution travels to the intermediate position assigned to the travel button.
  • Page 18: Restoring The Wireless Memory Of The Tubular Drive To Factory Settings

    Restoring the wireless memory of the tubular drive to factory settings There are a number of options: • Using a programmed CentronicPlus transmitter • Using the universal programming unit (item no. 4935 000 001 0) The set limit positions and all of the other set functions (intermediate position I, intermedi- ate position II, fabric untensioning, stop behaviour, obstruction detection) are retained.
  • Page 19 Using the universal programming unit (item no. 4935 000 001 0) Connect the wires of the tubular drive to those of the same colour in the programming unit. Connect the programming unit to the mains supply. Now press and hold the button "Tubular drive with electronic limit switching and ra- dio".
  • Page 20: Commissioning With A Centronic Transmitter

    Commissioning with a Centronic transmitter Explanation of symbols UP button STOP button DOWN button Programming button Receiver confirms once or multiple times by "clicking" or "shifting" 1 = direction switch 2 = radio switch Unlocked Locked Locking bolt Moving part of the locking system on the front section of the sun protection system Bolt mechanism Fixed part of the locking system in the guide track of the sun protection sys-...
  • Page 21: Programming The Master Transmitter

    Connecting the tubular drive Connect the tubular drive to the power supply. 230V AC / 50 Hz 1 = blue 3 = black 2 = brown 4 = green / yellow Switch on the power. ► The tubular drive confirms. Readying the tubular drive for programming by switching on the power Switch on the power.
  • Page 22: Checking That The Running Direction Is Correct

    Checking that the running direction is correct The direction of rotation can only be changed if no limit position has been set. There are several ways to change the direction of rotation: • Changing direction of rotation via the direction switch •...
  • Page 23: Setting The Limit Positions

    Setting the limit positions Attention The tubular drives are designed for short-time operation (for the operating mode, please see technical data). An inbuilt thermal protection switch prevents overheating of the tubu- lar drive. During commissioning (long drop distance or long running time), the ther- moswitch may trigger.
  • Page 24: Deleting The Limit Positions

    Deleting the limit positions Attention When both or individual limit positions are deleted, all the other set functions (intermediate position I, intermediate position II, obstacle detection, run times) are deleted as well. Once set, the limit positions can only be deleted with the master transmitter. Deleted limit positions are displayed on the limit position status indicator.
  • Page 25: Programming Additional Transmitters

    Programming additional transmitters A sensor can be programmed without a master transmitter. To do so, set the receiver to programming mode or setting mode. Skip the first step "Press the programmed master transmitter's programming button for 3 seconds". In addition to the master transmitter, up to 15 further transmitters (of which a maximum of three can be sensors) can be programmed in the radio receiver.
  • Page 26: Overwriting The Master

    Overwriting the master There are two ways to overwrite the master: • Readying the tubular drive for programming by switching on the power • Readying the tubular drive for programming with the radio switch Readying the tubular drive for programming by switching on the power To ensure that the new master transmitter is programmed in the desired tubular drive only, all other tubular drives which are connected to the same power supply must be deactivated from the programming mode.
  • Page 27: Additional Functions With Centronicplus / Centronic

    Programming the run times This function is available with all CentronicPlus EasyControl transmitters and with Centronic devices only equipped with "MemoControl" transmitters from the Becker range of control units. Both limit positions must be set before the Memo function is set.
  • Page 28: Deleting The Run Times With A Centronicplus Transmitter

    5 seconds. Activating / deactivating the run times with a Centronic transmitter This function is only available with MemoControl transmitters from the Becker Centronic range of control units. The Memo function is activated and deactivated via the slide switch. The last changeover to be performed is valid.
  • Page 29: Restoring The Factory Settings Of The Tubular Drive

    Restoring the factory settings of the tubular drive The factory settings can only be restored via the universal programming unit (Item no. 4935 000 001 0). Connect the wires of the tubular drive to those of the same colour in the programming unit.
  • Page 30: Disposal

    Disposal The crossed-out bin symbol on the product indicates that the device is subject to mandatory disposal separate from household waste. This product must be handed over to a collection point for electrical and electronic equipment at the end of its service life. The packaging material must be disposed of properly.
  • Page 31: Error Messages

    Installation technician information on the installation location Tubular drive Model/type Installation location Error messages The tubular drive is blocked. ► The transmitter confirms with 10 red flashes of the LED ring. The tubular drive is overheated. ► The transmitter confirms with 5 red / yellow flashes of the LED ring. The tubular drive is not responding.
  • Page 32 Problem Remedy The LED ring lights up red when the receiver for the setting Reduce distance from receiver. mode is selected. Check electr. connection of the receiver. Put the receiver into programming mode. Add the transmitter to the installation. The required setting cannot be changed. Make sure that the CentronicPlus transmitter is in setting mode.
  • Page 33: Sample Wiring Diagram

    Sample wiring diagram 33 - en...
  • Page 34: Declaration Of Conformity

    Declaration of conformity 34 - en...

Table of Contents