EPO switch——Emergency power off protection
1. Introduction
Emergency Power Off (EPO) switch is used to maximise safety and minimise
damage by quickly disconnecting power to equipment or systems in the event
of an emergency or hazardous event.
The hybrid inverter can be connected to the EPO switch. When the EPO
switch is activated, the inverter will shut down all power sources, including the
grid and battery side, and the EPS function will not work. To restart the
equipment simply release the switch and turn it approximately 45° clockwise
so that it springs back, essentially releasing the button.
2. DC Breaker
2.1.Technical characteristics
• Robust, reliable, up to 3 million mechanical cycles, 500,000 electrical
lifetimes
• Flat-voltage slow-acting contacts with larger electrical clearance and greater
current carrying capacity
• Contacts contain 30% silver and can carry high currents
• Anti-falling design of fastening ring, coarse matte buttons, not easy to slip
• IP66 degree of protection
2.2. Technical Parameters
• Rated Current: 10A
• Rated Voltage: 37V~440V
• Number of Contacts: 1NO+1NC
• Operating Temperature: -25℃ ~ +85℃
• Waterproof Rate: IP66
• Mechanical Life: >500000 mating cycles
— 1 —

Advertisement

loading
Need help?

Need help?

Do you have a question about the H271800000014 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hinen H271800000014

  • Page 1 Copyright©2024 Hinen. All Rights Reserved. EPO switch——Emergency power off protection 1. Introduction Emergency Power Off (EPO) switch is used to maximise safety and minimise damage by quickly disconnecting power to equipment or systems in the event of an emergency or hazardous event.
  • Page 2 Copyright©2024 Hinen. All Rights Reserved. 2.3. Dimensions 3. EPO switch and hybrid inverter connection The COM port of the inverter is designed for the connection of the EPO switch, so please connect and install the EPO switch correctly. The EPO switch ports are defined as follows: Description 3.1.
  • Page 3 Copyright©2024 Hinen. All Rights Reserved. 3.2. EPO switch and 12KW three-phase hybrid inverter wiring Notice: 1. Use a wire no less than 24AWG for connection. 2. Please check the reliability of EPO cable connection periodically. If any abnormality occurs, please strengthen all connection terminals.
  • Page 4 Copyright©2024 Hinen. All Rights Reserved. Appendix 1. 6KW Single Phase Hybrid Inverter COM Terminal Definition and Installation — 4 —...
  • Page 5 Copyright©2024 Hinen. All Rights Reserved. 2. 12KW Three Phase Hybrid Inverter COM Terminal Definition and Installation — 5 —...