El.Mo ANIMA Technical Manual

Capacitive command keypad

Advertisement

Quick Links

ANIMA - ANIMAB
Capacitive command keypad
090010887

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ANIMA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for El.Mo ANIMA

  • Page 1 ANIMA - ANIMAB Capacitive command keypad 090010887...
  • Page 2: For The Installer

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 FOREWORD FOR THE INSTALLER: Comply strictly with current standards governing the installation of electrical systems and security systems, and with the manufacturer’s directions given in the manuals supplied with the products. Provide the user with full information on using the system installed and on its limitations, pointing out that there are different levels of security performance that will need to suit the user’s requirements within the constraints of the specific applicable standards.
  • Page 3: Generals

    • In stand-by status, ANIMA offers a shiny and uniform surface. Just touch lightly its surface to make a keypad appear. • Touch pad CapSense. It is possible to interact with the ANIMA keypad by simply touching its surface, for an immediate and easy interactivity.
  • Page 4: View Of The Keypad

    3.1 Keypad general signalling The ANIMA keypad provides light signals to indicate the different operating states. For more detailed information, refer to the documentation of the control unit to which the keypad is connected; in general, the most important messages are provided as follows: Green light used for various signalling.
  • Page 5: View Of The Keypad Board

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB 3.2 View of the keypad board Main elements of the keypad. Tamper button. Connector for I66 proxi key reader S1 reset jumper. connection. (NO = normal operating mode) Terminals for power supply and serial line connection.
  • Page 6: Installation

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 4. INSTALLATION 4.1 Pre-installation housing opening To perform the opening and closing operations of the housing, see the following images. Closed ANIMA keypad. In the bottom of the keypad, there are In the bottom of the keyboard there are...
  • Page 7: Wall Mounting

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB 4.2 Wall mounting Dimensions in millimeters for drilling and keypad wall fixing. Warning: Install the keypad bottom with the tip of the arrow upward. Holes for wall mounting. Tamper against tear. Slot for cable feeding.
  • Page 8: Flush Mounting

    The ANIMABOX model is designed for use with the ANIMA keypad: the frame and the box are black. The ANIMABOXB model is designed for use with the ANIMAB keypad: the frame and the box are white.
  • Page 9: Wirings

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB Insert the keypad inside the frame Move the keypad to the base. Lean the Screw the keypad to the flaps using supplied with the flush mounting box. keypad on the flaps on the frame.
  • Page 10: Keypad Connection Through Ultrabus Serial Line With External Power Supply

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 5.2 Keypad connection through ULTRABUS serial line with external power supply Cable to another keypad or device connected via ULTRABUS serial line to the control unit. 12 V from external power A - B serial line of the intrusion supply unit.
  • Page 11: Proximity Key Reader Connection

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB 5.4 Proximity key reader connection Requirements for keypad use in compliance with the EN50131 standard: - The keypad is programmed so that it can recognise the I66 proximity key reader presence (I66 connected: YES).
  • Page 12: Possible Connection Of Multiple Readers To The Keypad (Not Compliant With The En50131 Standard)

    KEY READERS AND OF THE CABLE LENGTH. 5.6 Operation with M4 electronic key To perform any operation with the M4 key, just present it to the sensible area of the ANIMA keypad or to the corresponding area of the I66 and I7 proximity key readers.
  • Page 13: Functions

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB 6. FUNCTIONS 6.1 Functional features The keypad is connected to the control unit bus dedicated to the peripheral devices. It integrates the “ETR” protocol (it is compatible with the control units listed in 6.3 section); the capacitive keyboard is also equipped with a configuration menu that allows the adjustment of the following functional parameters without opening the housing: A.
  • Page 14: Programming Menu

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 6.4 Programming menu The ANIMA capacitive keypad features a procedure that allows to change the operating settings through the programming menu. Two menu sections are available: BASE OPTIONS menu: it includes functional options that can not compromise the system safe operation.
  • Page 15: Version

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB To access the programming menu, press and hold the key for more than 5 seconds. When you enter the procedure, the following message appears: PROGRAMMING Version The first line (PROGRAMMING) indicates that you are in the programming menu, the second line (Version) indicates the sub-menu.
  • Page 16: Exit

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 PROXY LED ON This option allows to keep the LED indicators of the key reader (integrated in the keypad) ON with weak lighting even when the keypad indications are set to OFF.
  • Page 17: Program Menu

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB Once the calibration is completed, the following message appears: Calibrating OK Note: once the calibration of the capacitive sensor is completed, the keypad will automatically exit the programming menu; all changes made up to that moment will be saved.
  • Page 18: Operation

    ANIMA - ANIMAB - TECHNICAL MANUAL - 090010887 TAMPER I66: It is possible to activate/deactivate the I66 key reader presence check. If the control is active, in case the I66 key reader is missing, a keypad tamper event will be triggered.
  • Page 19: Panic

    090010887 - TECHNICAL MANUAL - ANIMA - ANIMAB 7.3 Panic The panic function can be activated by pressing the * and # keys simultaneously. 7.4 Factory configuration restore Use the following procedure to restore the factory configuration parameters: 1. Open the keypad.
  • Page 20: Table Of Contents

    6.3 Keypad compatibility with the EL.MO. control units ....... . .

This manual is also suitable for:

Animab