Window-type room air conditioner ( cool ) (16 pages)
Summary of Contents for Samsung LENNOX M22D
Page 1
M I N I - S P L I T S Y S T E M S M22D CASSETTE | Four-Way (2 X 2) Cassette Indoor Units | 2 x 2 | R-32 | 60 Hz R E S I D E N T I A L / C O M M E R C I A L 0.75 to 1.5 Tons P R O D U C T S P E C I F I C AT I O N S ( E H B ) M22D 2 x 2 Cassette Unit (Shown with...
Page 2
CO N T ENTS Air Throw Data............14 Approvals And Warranty .
• Supplemental option • Connect smart TVs, smart appliances, smart speakers • Emergency heat option and brands like Samsung, Ring, Nest and Philips Hue - all from one free app • Compressor lockout option to only operate external heat source when outside temp is below X°...
Page 4
R EMOT E C ON T R O LLERS - O PTIO NA L WIRELESS REMOTE CONTROLLER (VSTAT01P-1) ”Calm Air” Button • Operates during Cool, Dry, or Fan mode • Complete remote control of system • Closes the louvers and allows air through the holes in •...
Page 5
R EM OT E CO NT R OLLER MENU S A ND F U NCTIONS ( VSTAT 01P-1) NOTE - Press the “Options” button to Start. The display changes to match the menu function selected. Left and right arrows scroll through function selections. NOTE - Functions available depend on the type of indoor unit.
R EM OT E CO NT R OLLERS - O PTIONAL • Outing function to keep a minimum heating (61 to 72°F) and cooling (77 to 86°F) temperature while away • When Outing mode is activated, the unit will operate at the specified Outing temperature.
Page 7
TOUCHS CR EEN WIRED C ON TROLLER F U NCTIO NS ( VSTAT02P-1) IR receiver (hidden) Display Buttons NOTE - Functions available depend on the type of indoor unit. Number Description Displays system mode of operation Displays quiet operation Displays Indoor temperature/Set temperature Displays indoor unit fan speed Displays air swing (Up/Down) Displays ON/OFF time (scheduled time)
Page 8
TOUCHS CR EEN WIRED C ON TROLLER F U NCTIO NS ( VSTAT02P-1) NOTE - Functions available depend on the type of indoor unit. Number Description Operation on/off button Turn the system power on/off Mode button Select a desired system operation Temperature setting button Set a desired temperature and adjust the time Fan speed button...
Page 9
• Filter replacement alarm display and reset • MDS (Motion Detection Sensor) Indirect/Direct Control (for supported indoor units, accessory may be required) • Time synchronization with supported Samsung central • Long Reach Function (for supported indoor unit models) controllers • Automatic air volume enable and status viewing (for •...
Page 10
O PTIO NA L CO NTR O L A C CESS O RIES Thermostat Adaptor NOTE - Features available depend on the type of indoor unit. Features • Allows control of Lennox mini-split systems with a standard 24VAC thermostat • One adaptor per indoor unit connected to the F3-F4 communication line •...
Page 11
S PECIF IC AT IO NS M22D Model M22D009S6 M22D012S6 M22D018S6 Tons 0.75 Line voltage data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 Connections Liquid (flare) - in. Gas (flare) - in. Condensate drain OD - in. Air Volume - cfm (Turbo/High/Medium/Low) 283 / 247 / 212 325 / 283 / 226 371 / 336 / 300 Output (W)
Page 12
S O UN D D ATA Sound Pressure level Unit: dB(A) Model H H i i g g h h M M i i d d L L o o w w M22D009S6-1P M22D012S6-1P 1.5m M22D018S6-1P Microphone • NC Curve 2) M22D012S6-1P 1) M22D009S6-1P NC 70...
S O UND DATA Sound Power level Unit: dB(A) NOTE Model C C o o o o l l i i n n g g • Specifications may be subject to change without prior notice M22D009S6-1P - Sound power level is an absolute value that a sound source generates.
Page 14
A IR T HR O W D ATA M22D009S6-1P • Cooling Air Velocity distribution • Cooling Temperature distribution Discharge angle : 41˚ Discharge angle : 41˚ • Heating Air Velocity distribution • Heating Temperature distribution Discharge angle : 56˚ Discharge angle : 56˚ M22D012S6-1P •...
Page 15
A IR T HR O W D ATA M22D018S6-1P • Cooling Air Velocity distribution • Cooling Temperature distribution Discharge angle : 41˚ Discharge angle : 41˚ • Heating Air Velocity distribution • Heating Temperature distribution Discharge angle : 56˚ Discharge angle : 56˚ M22D Four-Way Cassette Indoor Units | 2 x 2 | Page 15...
Page 16
D IM EN SI ON S UNIT 22-7/8~23 (581~584) (Ceiling opening) 24-3/8 (619) 19-3/4 (502) 22-7/8~23 (581~584) (Ceiling opening) 24-3/8 (619) 19-3/4 (502) HANGING BRACKETS (4) TOP VIEW CONTROL PANEL BOTTOM VIEW (Panel) 7/8 (22) 7/8 (22) 7/8 (22) 7/8 (22) 22-5/8 (575) 22-5/8 (575) DRAIN...
D IM EN SI ON S C ENTER O F GRAVIT Y 12-5/8 (321) 5-3/4 (146) TOP VIEW SIDE VIEW IN STALL AT IO N C LEAR ANC ES 59 (1499) 11-3/4 (298) Minimum Minimum 5/8 (16) 3/4 (19) Minimum 98-1/2 (2502) Minimum M22D Four-Way Cassette Indoor Units | 2 x 2 | Page 17...
Page 18
Visit us at www.Lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-9-LENNOX NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency.
Need help?
Do you have a question about the LENNOX M22D and is the answer not in the manual?
Questions and answers