Do you have a question about the HYX-EF215P2 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for HYXIPOWER HYX-EF215P2
Page 1
User Manual AIR COOLING ENERGY STORAGE SYSTEM HYX-EF215P2 / HYX-EF215P2-C Carefully read this inverter user instructions before using. Read and save these instructions.
Page 2
ZHEJIANG HYXI TECHNOLOGY CO., LTD (hereinafter referred to as "HYXiPOWER"). TRADEMARKS and other HYXiPOWER trademarks are the trademarks or registered trademarks of HYXiPOWER All other trademarks mentioned herein are the properties of their respective owners.
User Manual Contents CONTENTS Preface ..............................1 Overview ..................................1 Scope of Application .............................. 1 For Readers ................................1 Use of the Manual ..............................1 Use for Symbols............................... 1 1. Safety Precautions ..........................3 1.1 Personal Safety ..............................4 1.2 Electrical Safety ..............................5 1.3 Environmental Requirements ........................
Page 4
User Manual Contents 2.11 System Communication ..........................27 2.12 Transportation and storage ........................27 3. Installation ............................29 3.1 Installation Principles ........................... 29 3.2 Installation Notes ............................29 3.3 Foundation Requirements .......................... 29 3.4 Installation Preparation ..........................30 3.5 Equipment installation (structural supplement) .................. 31 3.5.1 Equipment Installation ..........................
Overview This manual mainly introduces the installation, electrical connection, debugging, and fault handling methods of the HYX-EF215P2、 HYX-EF215P2-C energy storage system product (hereinafter referred to as the energy storage system). Before installing and using the energy storage system, please read this manual carefully, understand safety information, and be familiar with the functions and characteristics of the energy storage system.
Page 6
User Manual Preface CAUTION • Indicates a low potential hazard which, if not avoided, could result in moderate or minor injury. NOTICE • Indicates a potential risk which, if not known to be avoided, could result in the equipment not functioning properly or in property damage.
User Manual 1. Safety Precautions 1. Safety Precautions STATEMENT: Before transporting, storing, installing, operating, using, or/or maintaining the equipment, please read this manual first, strictly follow the instructions in the manual, and follow all safety precautions marked on the equipment and in the manual. In this manual, "equipment" refers to the products, software, components, spare parts, and/or services related to this manual;...
User Manual 1. Safety Precautions operation, or non company reasons. 1.1 Personal Safety Live operation is strictly prohibited during the installation process. It is prohibited to install or remove cables with electricity. When the cable core comes into contact with the conductor, it may generate an arc, electric spark, or fire explosion, which can cause fire or personal injury.
User Manual 1. Safety Precautions • Trained personnel: Personnel who have received appropriate technical and safety training and have necessary experience, can be aware of the potential dangers that may arise when performing a certain operation, and can take measures to minimize the danger to themselves or other personnel.
User Manual 1. Safety Precautions • When liquid is found entering the equipment, please immediately turn off the power and prohibit further use. • Before operating the equipment, it is necessary to carefully check that the tools used meet the requirements and register them in the register; After the operation is completed, retrieve it according to the number to prevent it from being left inside the equipment.
User Manual 1. Safety Precautions • Do not damage the grounding conductor. • For devices using three core sockets, it is necessary to ensure that the grounding terminal in the three core socket is connected to the protective ground. • If it is a high contact current device, before connecting to the input power supply, the protective grounding terminal of the device casing must be grounded to prevent the contact current of the device from causing electric shock to the human body.
User Manual 1. Safety Precautions capacity and temperature rise. NOTICE Anti Static Requirements • The static electricity generated by the human body can damage the static sensitive components on the single board, such as large-scale integrated circuits (LSIs), etc. • Before touching equipment, such as single boards, modules with exposed circuit boards, or specialized integrated circuit (ASIC) chips, please comply with electrostatic protection regulations, wear anti-static work clothes, anti-static gloves or wristbands,...
User Manual 1. Safety Precautions • It is strictly forbidden to install the equipment in an environment with metal conductive dust, magnetic conductive dust. • It is strictly forbidden to install the equipment in areas where microorganisms such as fungi and mold can easily grow.
User Manual 1. Safety Precautions • Without the company's evaluation, it is forbidden to carry out arc welding, cutting and other operations on the equipment. • It is forbidden to install other equipment on top of the equipment without the company's evaluation.
Page 15
User Manual 1. Safety Precautions the inclination angle is α ≤ 10° after removing the package. Aerial Work Safety • Operations carried out at a height of more than 2 meters above the ground are classified as aerial work, and guardians must be set up for aerial work. •...
User Manual 1. Safety Precautions meets the requirements, and it is strictly forbidden to use it with excessive weight. • The ladder must be placed in a stable place, and someone must hold the ladder when working. • When climbing ladders, keep your body steady and ensure that your center of gravity does not deviate from the edge of the ladder frame to reduce danger and ensure safety.
User Manual 1. Safety Precautions • The energy storage system should be inspected regularly and not less than once a month. • When the system is live for inspection, you should pay attention to the danger warning signs on the equipment and avoid standing at the cabinet door. •...
Page 18
User Manual 1. Safety Precautions pipe and other water-prone locations to prevent liquid from entering the equipment and causing equipment failure or short circuit. • When the battery is installed and commissioned, it must be equipped with fire-fighting facilities in accordance with the requirements of the construction standards and specifications, such as fire-fighting sand, carbon dioxide fire extinguishers, etc.
Page 19
User Manual 1. Safety Precautions CAUTION • Your improper maintenance causes the battery to be frequently over discharged, your onsite expansion or long-term inability to fully charge, etc.; • You have not carried out proper maintenance of the battery in accordance with the •...
Page 20
User Manual 1. Safety Precautions dispose of batteries as household waste. Improper disposal of the battery may result in environmental contamination or explosion. • If the battery leaks or is damaged, please contact technical support or a battery recycling company for disposal. •...
STS Function Built-in STS module 2.2 Product Overview HYX-EF215P2 series energy storage outdoor cabinet is an all-in-one battery energy storage system. It is built around a 100kW power platform and equipped with a 215kWh air-cooled battery. The equipment is safe and reliable, and is suitable for scenarios such as industrial...
User Manual 2. Product Overview Nominal Input Power 50 / 50kW Nominal Current Per MPPT 138A STS Side Off-grid Switching Time ≤ 20ms General Data System Parallel Units Operating Temperature Range -20 to 50° C Operating Humidity Range 0 - 95%RH Noise ≤...
User Manual 2. Product Overview WIFI antenna Pressure relief valve Vent valve Exhaust vent 5kW air conditioning unit Back parts introduction 2.4.1 Main specifications of battery cluster:...
Page 25
User Manual 2. Product Overview Main specifications of battery cluster Item Specifications Remark Nominal voltage 768V DC Cell voltage 3.2V Recommended single cell Operating voltage range 672~864V DC voltage range 2.8~3.6V Nominal capacity 280Ah 0.5C, 25℃ single cell voltage 2.5V-3.6V Nominal power 215kWh Series-parallel configuration...
User Manual 2. Product Overview 2.4.2 Battery PACK Battery PACK main specifications Item Specifications Remark Nominal voltage 51.2V Single cell voltage 3.2V Single cell voltage range Operating voltage range 40~58.4V DC 2.5~3.65V Nominal capacity 280Ah 0.5C,25℃ Nominal power 14.336kWh 0.5C,25℃ Series-parallel configuration 1P16S 2 battery modules in series...
User Manual 2. Product Overview 2.4.3 MPPT main specifications: Parameter table of 50kW DCDC bidirectional converter Product Name DC/DC Bidirectional Converter BAT side DC voltage (V) Voltage range 300-900V, full load 310V-900V High voltage side battery voltage (V) Voltage range 300-900V, full load 500V-900V Rated power (KW) 50kW Peak power (KW)
Page 28
User Manual 2. Product Overview 100kW PCS module technical parameters Product Name AC grid-connected parameters Rated output power 100kW Overload capacity 1.1 times long term, 1.2 times 1 minute ≤ 35℃ Rated voltage AC 400V Rated output current 145A Communication access method Three-phase four-wire Isolation method Non-isolated...
User Manual 2. Product Overview 2.4.5 STS One-time Specification STS transfer switch technical parameters Rated voltage 0.4kV Voltage range -15%~+15% Rated current 433/288 Rated Power 300/200kVA Rated frequency 50Hz/60Hz On-grid and off-grid switching time ≤ 20ms Protection level IP20 size 440*370*200mm weight 15KG...
User Manual 2. Product Overview Signal and temperature Significance Remark switches TR and GND are 0V to turn on Trigger signal the thyristor, 15~24V to turn off the thyristor Temperature switch (normally closed) 80 degree protection The voltage between ERR and Fault light indication GND is 15~24V, and the fault indicator is lit.
User Manual 2. Product Overview 2.6 Temperature characteristics Battery charge and discharge temperature: -20℃ to +55℃ (discharge)/ 0℃ to +45℃ (charging) Safe storage environment temperature: -20℃ to +60℃ Recommended storage temperature: 25±5℃ Recommended working environment temperature: 0℃ to +40℃ 2.7 Test data The battery system can detect the battery operating status (voltage, current, temperature, SOC/ SOH/SOP estimation, etc.
Page 32
User Manual 2. Product Overview rolled, or pressed. Direct rain and snow and mechanical impact should be avoided during transportation. Storage The system should be stored in a dry warehouse and should not be exposed to the sun or rain. No harmful gases, flammable or explosive products are allowed in the warehouse.
User Manual 3. Installation 3. Installation 3.1 Installation Principles The energy storage system is a high-voltage energy storage device and is a dangerous item. Improper operation and use by non-professionals may cause serious consequences such as electric shock, combustion, and explosion. The installation and maintenance of the battery system must be performed by professional technicians or trained designated personnel .
User Manual 3. Installation 300mm, with grade 3 steel, double-layer and bidirectional. • The steel bars shall be of HRB400 grade (grade 3 steel symbol ) and shall be subjected to anti-corrosion treatment in accordance with relevant specifications after rust removal. •...
User Manual 3. Installation 3.5 Equipment installation (structural supplement) 3.5.1 Equipment Installation Installation hole locations 3.5.2 Cable Wiring Photovoltaic wiring steps : • The photovoltaic wiring is on both sides of the electrical cabinet, with two wirings. The first wiring is divided into PV+, PV-, and the second wiring is divided into PV+, PV-.
Page 36
User Manual 3. Installation • Remove the lower baffle at the rear of the cabinet - thread the AC wires into the cabinet - ground the system inside the cabinet - connect the AC wires inside the cabinet - organize the wire harnesses - seal the cable entry holes.
Page 37
User Manual 3. Installation Wiring steps : • Confirm the power-off status : the grid-side circuit breaker connected to the upper level of the energy storage cabinet is in the disconnected state ; • Confirm the phase sequence: confirm the phase sequence of the incoming cable of the cabinet ( phase A, phase B, phase C, neutral line, PE );...
User Manual 4.Power on the system 4.Power on the system CAUTION • To ensure the long-term safe and reliable operation of your energy storage system, please read and follow the following instructions carefully. • battery damage and other losses caused by failure to use in accordance with the specified requirements or use beyond the specified range , Huayuxin Technology will not be responsible.
Method 2: Scan the QR code through the APP to add industrial and commercial energy storage cabinet equipment. After scanning and adding, register on the HYXiPOWER Smart Energy Platform. Log in to the official website: https://www.hyxicloud.com/#/login, enter your username and...
User Manual 5.Equipment Operation Control 5.2 EMS system main interface After successful login, you will enter the main interface of the system, which is divided into three areas. The left side of the interface shows the basic information of the site and the status of peripherals.
User Manual 6.System Power-off 6.System Power-off 6.1 Power-off operation Primary circuit power off: PCS is in standby mode, battery high voltage box is closed, PCS AC switch and high voltage are disconnected. The DC switch of the box is turned off, and the system is powered off When there is charge and discharge current in the main circuit of the battery system, the system will not be able to power off.
User Manual 7. Warranty 7. Warranty • The warranty for all equipment shall be in accordance with the contract requirements and the business agreement between the two parties. • During the warranty period, the supplier shall arrange professionals to carry out necessary testing and maintenance on the equipment in accordance with the contract requirements.
User Manual 8. Remark 8. Remark In order to protect the legitimate rights and interests of both parties and avoid unnecessary losses, product failure or damage caused by the following reasons will not be covered by the warranty Free services: •...
User Manual 9. Appendix 9. Appendix 9.1 Common fault information and some solutions Fault name Possible cause of failure Treatment measures Remark 1. Check if the monitoring power supply indicator light is 1. The secondary circuit of the 2. Refer to the monitoring The system is not system is not powered electrical diagram to see if...
Page 45
User Manual 9. Appendix Check if the PCS is working Charge and discharge The system charge and properly. Please contact the overcurrent stop discharge current is higher manufacturer for after-sales Machine protection than the protection value service. Use remote background to shut down PCS, BMS System insulation 1.
User Manual 9. Appendix 9.2 Contact Information If you have any questions about this product, please contact us. In order to provide you with faster and better after-sales service, we need your assistance in providing the following information. • Equipment model: •...
Page 47
UM_HYX-EF215P2-M(MS)_V1.0-202412_EN The manual is subject to change without notice while the product is being improved. Zhejiang Hyxi Technology Co., Ltd. Room 216, Block A, Building 1, No. 57 Jiang'er Road, Changhe Street, Binjiang District, Hangzhou, Zhejiang Province, China www.hyxipower.com support@hyxipower.com...
Need help?
Do you have a question about the HYX-EF215P2 and is the answer not in the manual?
Questions and answers