Advertisement

Quick Links

ARISTEL NETWORKS
AN1808 4G Gate Opener
User Manual
`
Please read these instructions completely before use.
4G Gate Opener
1/18
Rev. V1.5, JAN 2025

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AN1808 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aristel AN1808

  • Page 1 ARISTEL NETWORKS AN1808 4G Gate Opener User Manual Please read these instructions completely before use. 4G Gate Opener 1/18 Rev. V1.5, JAN 2025...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ....................3 2. BRIEF INTRODUCTION ....................3 3. PRODUCT FEATURES ....................4 4. STANDARD PACKING LIST ..................4 5. INSTALLATION ......................4 5.1 SIM card installation ....................4 5.2 Antenna Connection .....................5 5.3 Wiring Diagram ....................5 5.4 Power Supply .......................6 6.
  • Page 3: Safety Precautions

    Thank you for purchasing the 4G Gate Opener. Please read this manual carefully before using. Be sure to keep this manual for future reference. 1. SAFTY PRECAUTIONS Unplug the power adapter before cleaning. Do not use liquid cleaners or aerosol Cleaners. Use a damp cloth for cleaning.
  • Page 4: Standard Packing List

    Send SMS notification when a short circuit exists on inputs 1150 telephone numbers memory for access control by caller ID automatic number recognition at no call cost to user. To open the gate/door by password with 4 digit code access option if the number is not stored in the access control section.
  • Page 5: Antenna Connection

    Fig1 5.2 ANTENNA CONNECTION Ensure that there is good network reception at the location where it will be installed. If you use an antenna with a 3 metre cable, install it as high as possible on the top of the pillar for best possible reception.
  • Page 6: Power Supply

    Fig3 5.4 POWER SUPPLY The 4G Gate Opener is designed to work with power supplies 12V~24V AC or DC. The power supply should be capable of supplying a constant current of no less than 1amp. After a final check of wiring switch on the power. Allow 20~30 seconds for the unit to boot up and detect the network.
  • Page 7: Led Indicators

    6. LED INDICATORS Fig4 LED Status Definition Number Solid Flash Trigger input 3 Input 3 active Standby In triggering setup time & Sending SMS (24+Time#) Input 2 active In triggering setup time Trigger input 2 Standby & Sending SMS (17+Time#) Input 1 active In triggering setup time Trigger input 1...
  • Page 8: Operation

    7. OPERATION Programming of authorized telephone numbers in the unit will enable these numbers to call the gate opener’s Mobile number, and whenever the unit receives a call, it will recognize the authorized telephone number(s) calling it, and will disconnect without answering (so there will be no charge). The gate or door relay will be activated.
  • Page 9: Programming By Text Message

    Note: *programming dialing in can’t be used from telephones which are already programmed to open the door when they dial the Gate Opener. * If the number is programmed to open the door but you still would like to use the same number to dial in for programming, then you can disable Caller ID display (withhold the number) on the mobile.
  • Page 10: Administrator Number

    9. ADMINISTRATOR NUMBER Once the administrator number is stored, the unit will only accept programming from this number and only via SMS programming. Example: Program a mobile number as an administrator number via SMS Mobile number: 0865682554 Command to use *12*1234#74 [Admin number]# SMS format *12*1234#740865682554# To delete the Admin number *12*1234#74*# 10.
  • Page 11: Check A Log Of Dial In Numbers Via E-Mailor Sms

    13. CHECK A LOG OF DIALED IN NUMBERS VIA E-MAIL OR SMS This system allows you to save dial in numbers log and will then automatically send the record via e-mail or SMS as your request. There is a list of commands you need and examples to guide you on the settings for this feature. Please setup following required parameters and commands before you can use it.
  • Page 12 Function SMS command codes E-mail subject setting *43*1234# e-mail subject# Command code Example: To immediately send current dial in *44*1234# numbers log via email or SMS SMS reply: successful or failed *4[N]*1234# ( reply GPRS parameters) Check parameters setting N=1 ( reply e-mail parameters) N=2 ( reply recipient &...
  • Page 13: User Commands

    How to program checking a log of dialed in numbers via SMS There are 3 programming codes you will need to make this feature work You can program many different user command codes in a single text message with SMS command format. *12*1234 # [command Code1] # [command Code 2] # [command Code3] #..
  • Page 14 You can program many different user command codes in a single text message with SMS command format. *12*1234 # [command Code1] # [command Code 2] # [command Code3] #..Command Description settings Default 01 [new password]# Change password of Programming password:4 ~6digits 1234 Mode...
  • Page 15 Command Description settings Default 21[mode]# Set Input 2 mode Mode= 0, 1, 2 or 3 0 = Disable , 1 = Trigger 2 = Egress 1, 3 = Egress2 27 [mode]# Set Input 3 mode Mode= 0 or 1 0 = Disable , 1 = Trigger 28+IN*time start+ time Set time duration ( enable inputs ) 1, 2 or 3...
  • Page 16 User commands to check system info & control relay via SMS Command Description SMS Reply *21* 1234 # check signal strength and Signal Level = 0~31 operator From poor to strong [ number1]#[number2]#[number3]#..*22*1234# Reply stored numbers E:Next page / N: End Reply alarm contact *23*1234# numbers when inputs are...
  • Page 17: Specifications

    You can dial in or send SMS password code to the device to control relay. *71*5678#:Trigger relay 1 *72*5678#:Hold relay1 *73*5678#:Release relay1 *74*5678#:Trigger relay 2 *75*5678#:Hold relay 2 *76*5678#:Release relay 2 Aristel Networks Pty Ltd 4G Gate Opener 17/18 Rev. V1.5, JAN 2025...
  • Page 18 Ph. 03 8542 2300 Fax. 03 9544 3299 4G Gate Opener 18/18 Rev. V1.5, JAN 2025...

Table of Contents