Condenser Fan Error (CF E)
1
Reset the unit and Input
Test1 Mode.
(Push the button 1 time)
2
Check the fan rotating.
Does fan rotate?
Fan Motor
Yes
Go to 4
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Fan Motor
Copyright © 2023-2024 LG Electronics Inc. All rights reserved.
Only training and service purposes
Trouble Shooting
Go to 3
No
Change the
Yes
Fan motor
-42-
4
Check the Fan Motor voltage
Is Fan Motor voltage 12V?
TEST MODE 1
CON3
th
st
4
Pin ~ 1
Pin
Yes
5
Check the Fan Motor voltage
Is Fan control signal voltage
between 0V and 5V?
TEST MODE 1
CON3
0V<Voltage<5V
nd
st
2
Pin ~ 1
Pin
No
6
Check the Fan Motor voltage
Is Fan feed back voltage
between 0V and 5V?
TEST MODE 1
CON3
0V<Voltage<5V
rd
st
3
Pin ~ 1
Pin
No
7
Explain to customer
Replace
No
Main PCB
CON3
Voltage [V]
12V
Replace
No
Main PCB
CON3
Voltage [V]
Replace
No
Motor
CON3
Voltage [V]
Need help?