  • Page 1 DEHUMIDIFIER Owner’s Manual & Installation Manual Owner’s Manual Lorem KDM-20LWRC290 IMPORTANT NOTE: Read this manual carefully before installing or operating your new machine. Make sure to save this manual for future reference.
  • Page 2: Table Of Contents

    Table of Contents Important Reminders Important Reminders ..........................................01 Safety Precautions Safety Precautions ............................................01 Preparation Identi cation of parts..........................................09 Installation instructions..........................................09 Strorage instructions..........................................09 Caster installation and disassembly instruction................................09 Design Notice..............................................10 Positioning the unit..........................................10 When using the unit..........................................10 Operating Instructions Control Panel Features..........................................11 Other features...............................................
  • Page 3: Important Reminders

    Important Reminders 1) Press and hold for 3 secs the FILL LEVEL and buttons to activate Bucketless mode. 2) Bucketless mode should only be activated when an attached hose is in use. 3) Ensure that there are no items placed on top, and unit is not shaking while in use. 4) Handle the dehumidi er with care and avoid dropping it abruptly, instead, place it down gently.
  • Page 4 Do not route cord under furniture or appliances. Arrange cord away from tra c area and where it will not be tripped over. • Do not operate unit with a damaged cord or plug. Do not use the unit and contact our kolin hotline or authorized service centers for examination and for repair. •...
  • Page 5: Sociable Remark

    • The kolin dehumidi er’s nameplate is located on the unit and contains electrical and other technical data speci c to this unit. • Be sure the unit is properly grounded. To minimize shock and re hazards, proper grounding is important.
  • Page 6 WARNING for Using R32/R290 Refrigerant Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open ames, an operating gas appliance or an operating electric heater). Do not pierce or burn.
  • Page 7 1) Transport of equipment containing flammable refrigerants See transport regulations 2) Marking of equipment using signs See local regulations 3) Disposal of equipment using flammable refrigerants See national regulations. 4) Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's instructions. 5) Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
  • Page 8 Checks to the refrigeration equipment • Where electrical components are being changed, they shall be t for the purpose and to the correct speci cation. At all times the maintenance and service guidelines shall be followed. If in doubt consult the technical department for assistance. The following checks shall be applied to installations using ammable refrigerants: The charge size is in accordance with the room size within which the refrigerant containing parts are installed;...
  • Page 9: Charging Procedures

    9) Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental e ects. The check shall also take into account the e ects of aging or continual vibration from sources such as compressors or fans. 10) Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks.
  • Page 10 14) Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant.
  • Page 11: Preparation

    Preparation Identi cation of parts NOTE:All the illustrations in the manual are for explanation purpose only. Your machine may be slightly di erent. The actual shape shall prevail. The unit can be controlled by the unit control panel . control panel handle air intake grille quick glance light...
  • Page 12: Design Notice

    bottom of unit caster block Disassembly: 1.To remove the caster , use a screwdriver to prop up the block, then take it down. 2.Then remove the caster. Design Notice In order to ensure the optimal performance of our products, the design speci cations of the unit are subject to change without prior notice.
  • Page 13: Operating Instructions

    Operating Instructions Control Panel Features NOTE: The following control panels are for explanation purpose only. The control panel of the unit you purchased may be slightly di erent according to the models. Your machine may not contain some indicators or buttons.
  • Page 14: Fan Button

    PUMP feature(On some models) )/DOWN( ) buttons · Press and hold on the Up/Down buttons 2 second · Humidity Set Control buttons to initiate PUMP feature.Press and hold on the Up/ In Setting dehumidifying mode, The humidity level can be Down buttons 2 seconds again to stop PUMP feature.
  • Page 15: Other Features

    Protection Code: Setting dehumidifying mode P2-Bucket is full -- Empty the bucket and replace it in At setting dehumidifying mode, the unit can be adjusted in a the right position. range 35%~85%, and the humidity setting can be adjusted Eb-Bucket malfunction--Replace the bucket in the right (increase/decreasing) in 5%.
  • Page 16 Bucketless mode(on some models) √ The dehumidi er can be used without bucket when the unit is under Bucketless mode. The unit will not reminds the water to be full after entering the bucketless mode, therefore, it is suggested that: 10cm or more 1) Check whether the tube is properly connected;...
  • Page 17: Removing The Collected Water

    Removing the collected water Note: There are two ways to remove collected water. · When you remove the bucket, do not touch 1) Use the bucket any parts inside of the unit. Doing so may · When the unit is o ,if the bucket is full, the unit will damage the product.
  • Page 18 3) Pump draining (on some models) · Water can be automatically emptied into a oor drain · select the desired humidity setting and fan speed on or a suitable drainage facility by attaching the pump the unit for pump draining to start. ′′, Note: The pump operation on light blinks at 1Hz when drain outlet with a pump drain hose(Φod=1...
  • Page 19: Care And Maintenance

    Care and Maintenance Care and cleaning of the dehumidi er Turn the dehumidi er o and remove the plug from the wall outlet before cleaning. Clean the Grille and Case · Use water and a mild detergent. Do not use bleach or abrasives. ·...
  • Page 20: When Not Using The Unit For Long Time Periods

    When not using the unit for long time periods · After turning o the unit, wait one day for water collecting before emptying the bucket. · Clean the main unit, water bucket and air lter. · Cover the unit with a plastic bag. ·...
  • Page 21 The design and speci cations are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version. KPII040423...
  • Page 22 当机型为非可燃冷媒机型时,请进行以下变更: 删除Pg4-Pg8(WARNING for Using R32/R290 Refrigerant)内容。...