Current Tetra GEPS12-120U-NA Installation Manual

Led systems power supply

Advertisement

Quick Links

LED Systems Power Supply
GEPS12-120U-NA (120-277 VAC input/12VDC output/120W)
Power Supply Features
• Supports all 12 VDC Tetra Products
• Dry and Damp Locations Rated
• UL: Class 2, Class P, Type HL
• Two 60 Watt Output Banks
• 120-277 VAC Input
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
• Use only within an enclosure.
• When utilized within a sign, only the AC input connections need be
suitably enclosed.
RISK OF FIRE
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm
).
2
• Follow all local codes.
RISK OF ELECTRIC SHOCK OR FIRE
• Do not connect outputs in series or in parallel.
RISK INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The suitability of rain enclosure shall be determined if
intended for wet location.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d'alimentation Tetra
• Les connexions d'entrée CA doivent être convenablement enfermées. Le bloc
d'alimentation doit être enfermée ou rendue inaccessible aux utilisateurs
pendant l'utilisation normale.
• Utiliser uniquement dans une enceinte.
• Lorsqu'il est utilisé dans un panneau, seules les connexions d'entrée CA
doivent être convenablement fermées.
RISQUES D'INCENDIE
• N'utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
RISQUES DE CHOC ÉLECTRIQUES OU D'INCENDIE
• Ne pas connecter les sorties en série ou en parallèle.
CAUTION / ATTENTION
RISQUES DE BLESSURE
• Lors de l'exécution des installations décrites, des gants, des lunettes
de sécurité ou des lunettes de protection doivent être portées.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Installation Guide
SIGN356 | DOC-2007267
).
2
12
12
Volt
.
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the Tetra GEPS12-120U-NA and is the answer not in the manual?

Questions and answers

Summary of Contents for Current Tetra GEPS12-120U-NA

  • Page 1 Installation Guide SIGN356 | DOC-2007267 LED Systems Power Supply Volt GEPS12-120U-NA (120-277 VAC input/12VDC output/120W) Power Supply Features • Supports all 12 VDC Tetra Products • Dry and Damp Locations Rated • UL: Class 2, Class P, Type HL • Two 60 Watt Output Banks •...
  • Page 2 The switch voltage rating shall not be less than the branch circuit voltage. The switch must also support twice the amount of input current. NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line, neutral and ground connections, in accordance with National Electric Code (NEC) Article 600 and all local regulations.
  • Page 3 Page 3 of 3 (Rev 11/05/24) © 2024 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the SIGN356 | DOC-2007267 General Electric Company and are used under license. Information provided is subject to change without...