  • Page 1 NXFM150...
  • Page 2 The Fill-Rite FMS expansion system works in tandem with an installed Site Controller to Wireless Warnings......................... 3 increase the number of pumps you can monitor with Fill-Rite FMS. Ensure that you have completed installation of a Fill-Rite FMS Site Controller before installing your Expansion Hazardous Area Examples.....................
  • Page 3 Step 2: Fill out your company and contact information, and click the "Sign Up" button Step 3: In the top left corner of the page, underneath the Fill-Rite FMS logo, click the “Setup” button. The Setup page will walk you through all of the necessary steps and features to get your system going.
  • Page 4 1. Turn off all power to the pump at the breaker Failure to perform the below checks may result in the Fill-Rite FMS or fuel equipment being 2. Attach the 4 included Mounting Brackets and screws to the Expansion Module and use damaged or not working as intended.
  • Page 5 Fill-Rite FMS Hardware Power In / Power Out Fill-Rite FMS piggybacks power off of the Hose #1 power input. Your wiring configuration will depend on whether the pump runs on AC or DC power. Do Not piggyback input or output wiring unless the wires are sized correctly via NEC.
  • Page 6 A, B, and GND on the Expansion Module need to be connected to A, B, and GND on the Site Controller. Multiple NXFM150 Modules can be linked together in a series (up to 10 modules) using RS-485. Please use a 2 twisted pair and 1 shielded cable for RS485. Example: Beldon 3106a...
  • Page 7 4. Test Transaction: Have the Fill-Rite FMS administrator create a driver profile and pin code for you, and perform a test fueling using the Fill-Rite FMS mobile app. The Fill-Rite FMS app may perform a firmware update on first use.
  • Page 8: Certifications / Approvals

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including Certifications / Approvals interference that may cause undesired operation. Fill-Rite FMS - NXFM150 FuelCloud, Inc. Fill-Rite FMS - NXFM150 RATINGS: Max Ambient T emperature Rating: 50 °C...