Watex CMB-10 Installation And Operation Manual

Iron removal water filter

Advertisement

Quick Links

Installation and operation manual
WATEX CMB-10/12/13/14
IRON REMOVAL WATER FILTER
Watch CMB filter first
start-up video:
More info: https://watex.eu/en/iron-
removal-filters/iron-removal-filters-
watex-cmb
Read the instructions carefully before use!
WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMB-10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watex CMB-10

  • Page 1 Installation and operation manual WATEX CMB-10/12/13/14 IRON REMOVAL WATER FILTER Watch CMB filter first start-up video: More info: https://watex.eu/en/iron- removal-filters/iron-removal-filters- watex-cmb Read the instructions carefully before use! WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 2: Table Of Contents

    Time settings ........................14 4.2. Manual rinsing........................14 4.3. Rinsing mode duration and volume settings ................ 15 4.4. Rinsing day and time settings ....................15 4.5. Operational control ....................... 16 WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 3: Introduction

    • Connection to power 220 V • Water pressure above 2.5 bar. • The room temperature over 0° C • Water temperatures up to 25° C • Proper system connection WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 4: Essential Equipment Specifications

    Regeneration cycle– backwash (min) Regeneration cycle– brine (min) Water mains connection dimensions (inches) ¾’’ Drainage connection (inches) Working pressure (bar) 2.5 - 6 Power consumption 10 W WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 5: Relocation

    Do not take the filter behind the bottom black plate, because it is not secured to the tank and filter can fall out of your hands! WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 6: System Operation

    For removal of iron, the filter media used in the filter is the fine quartz sand 0.7x1.25 mm and 0.4x0.8 mm and the Aqua Mandix. This filter media is coated with a thin layer of MnO serving WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 7: Control Unit

    On the left part of the control valve housing at the outlet manifold is a built-in meter that counts the quantity of water consumed. The rinse algorithm is based on the volume of water consumed, which is counted by the built-in meter. WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 8: System Operation

    Service cycle time depends on the incoming water quality and the amount of the filter media. The WATEX CMB series control valve has a built-in meter that lists the quantities of water consumed. The electronic display of the filter makes it possible to adjust the water volume (m3) after which consumption follows the regeneration.
  • Page 9: Air Suction Mode

    If in this cycle the air is not sucked in the filter will not ensure the normal operation! Consequently, this cycle is the most important throughout the rinsing cycle. This mode lasts for approximately 27-40 minutes. Air injection check valve WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 10: Installation

    Place the water filter so that the distance between the drainage outlet and the filter is minimized. Perform a general preventive maintenance at least once a year. Typical installation example WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 11: Water Supply Connection

    Note: the bend of the sewer connection has the sealing ring; it is possible to turn it in the desirable direction. Turning angle is 270 WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 12: Electrical Connections

    4. The tip to be connected to the contact terminals at the right lower part of the motherboard. 5. The rest of the cable should be placed along side the frame of the motherboard behind the specially designed clamps. WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 13 6. Push back the motherboard-mounting frame to fastening tab and secure it in the original position. 7. Install the front button cover. WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 14: First Start

    Watch the video for CMB filter first start-up Usually all key operating parameters of the WATEX CMB series filter have already been set at the service center. The only thing that is planned to set for the first run is the time setting.
  • Page 15: Rinsing Mode Duration And Volume Settings

    2) in the lower left corner starts flashing arrow and digit “2”. It indicates the start of the rinsing cycle at 2.00 A.M. Using the keys “UP” and “DOWN” , set the desired WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 16: Operational Control

    The user can go through all the display readings and return to the time. If the system is to be before the pre-set time, the display will show the words REGEN TODAY (regeneration today). WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 17: Problems And Solutions

    Electronic plate is incorrectly i. Make sure that the electronic circuit board is connected to the base of the properly connected to the drive bracket. drive WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...
  • Page 18 NEXT and REGEN buttons have been pressed to re-reset control valve. WATEX Ltd., Latvia, Riga, Ganibu dambis 27 k-5, info@watex.eu, Tel. +371 67381989, www.watex.eu...

This manual is also suitable for:

Cmb-12Cmb-13Cmb-14

Table of Contents