gefran KMC Series Information For Use
gefran KMC Series Information For Use

gefran KMC Series Information For Use

Pressure probes

Advertisement

Quick Links

SAE
J1939
E
1
1. GENERAL PRECAUTIONS ...................................................................................................................................................2
2. TRANSMITTERS WITH AMPLIFIED DIGITAL OUTPUT ......................................................................................................2
2.1. Standard installation (recommended) ...........................................................................................................................2
2.2. Electrical connections ...................................................................................................................................................3
2.3. Interfaces with SRP/CS ................................................................................................................................................3
3. TECHNICAL SPECIFICATIONS ............................................................................................................................................4
3.1. EMC Tests performed for mobile hydralic and automotive applications ......................................................................6
3.2. EMC Tests performed for industrial applications ...........................................................................................................7
4. SAFETY MANUAL (for CANopen Safety transducers only) .............................................................................................8
4.1. Application .....................................................................................................................................................................8
4.3. Restrictions of use .......................................................................................................................................................9
4.4. Maintenance and periodic inspections ..........................................................................................................................9
4.5. Indication of response time ...........................................................................................................................................9
4.6. Suspension of the safety function ................................................................................................................................9
4.7. Indications and alarms ................................................................................................................................................10
4.8. Failures and troubleshooting ....................................................................................................................................... 11
4.9. Safe Parameterization ................................................................................................................................................ 11
4.9.1.
Safe Communication Parameterization ............................................................................................................... 11
4.9.2.
Safe Application Parameterization .......................................................................................................................12
80792A_Manual of Electrical Installation for Pressure Probes Complete_KMC_10-2024_ENG
Information for use for Pressure Probes
KMC series
CONTENTS
Code 80792A
Edition 10-2024 (translation of original version)
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KMC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for gefran KMC Series

  • Page 1: Table Of Contents

    Information for use for Pressure Probes KMC series J1939 Code 80792A Edition 10-2024 (translation of original version) CONTENTS 1. GENERAL PRECAUTIONS ..............................2 2. TRANSMITTERS WITH AMPLIFIED DIGITAL OUTPUT ......................2 2.1. Standard installation (recommended) ...........................2 2.2. Electrical connections ..............................3 2.3. Interfaces with SRP/CS ..............................3 3.
  • Page 2: General Precautions

    The sensor must be protected against accidental knocks and used in accordance with the instrument’s ambient characteristics and performance levels. Sensors must be powered with non distributed networks. 2. TRANSMITTERS WITH AMPLIFIED DIGITAL OUTPUT Transducers: KMC series Outputs: CANopen (*), J1939, CANopen Safety (*) (*) with CiA 404 Device Profile Installation remarks - The transducer must be grounded (normally through the machine body or equipment it is installed on).
  • Page 3: Electrical Connections

    Many industrial applications, especially in hydraulics, could present dangerous phenomena like cavitation, liquid hammer or pressure peaks, due for example to pumps The KMC series, upon request, is available with an integrated pressure snubber which, start and stop or fast closing of a valve.
  • Page 4: Technical Specifications

    3. TECHNICAL SPECIFICATIONS Non Linearity (BFSL) ± 0.15% FS (typ); ± 0.25% FS (max) Hysteresis + 0.1% FS (typ); + 0.15% FS (max) Repeatability ± 0.025% FS (typ); ± 0.05% FS (max) Zero offset tolerance ± 0.15% FS (typ); ± 0.25% FS (max) Span offset tolerance ±...
  • Page 5 RANGE 1000 (Bar) Overpressure 1200 1200 (Bar) Burst pressure 1000 1500 1500 1500 (Bar) EMC compliance according to: Title Standard / Directive /Regulation 2014/30/EU EMC Directive (Electromagnetic compatibility) ISO 13766-1:2018 Earth-moving and building construction machinery — Electromagnetic compatibility (EMC) of machines with internal electrical power supply —...
  • Page 6: Emc Tests Performed For Mobile Hydralic And Automotive Applications

    3.1. EMC Tests performed for mobile hydralic and automotive applications 2015/ 208/EU Test name Test parameter 14982 Art. 19, 13766-1 13766-2 An. XV 30-75 MHz, 64-54 dBμV/m Broadband 75-400 MHz, 54-65 dBμV/m NO REQ. radiated emission 400-1000 MHz, 65 dBμV/m 30-75 MHz, 54-44 dBμV/m Narrowband 75-400 MHz, 44-55 dBμV/m...
  • Page 7: Emc Tests Performed For Industrial Applications

    3.2. EMC Tests performed for industrial applications Gefran KMC products are tested also against industrial standard according to 2014/30/EU Directive (EMC): • EN 61326-1 “Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1 general requirements”...
  • Page 8: Safety Manual (For Canopen Safety Transducers Only)

    4. SAFETY MANUAL (FOR CANOPEN SAFETY TRANSDUCERS ONLY) 4.1. Application The pressure sensor KMC CANopen Safety performs the following safety function: Measurement and transduction of the read pressure value, with generation of a signal in CANopen Safety within the stated measurement uncertainty (see Sec.
  • Page 9: Restrictions Of Use

    4.2. Effects on the safety function of performance deviations The acceptability limit of metrological performance deviations in order not to induce loss of the safety function is ± 5% of the read value at room temperature 4.3. Restrictions of use The device must only be used in accordance with these operating instructions for mechanical installation, electrical connection, environmental conditions and use in order to maintain the declared SIL/PL.
  • Page 10: Indications And Alarms

    4.7. Indications and alarms The KMC CANopen Safety transducer detects specific anomalies and provide safety alarm output. The reaction to anomalies brings the output of safety function to Preoperational state, which means no communication of SRDO Table 1 indicates the detected failures and their raw effect on output Failure Output Power supply cable broken...
  • Page 11: Failures And Troubleshooting

    4.8. Failures and troubleshooting In case of failures or malfunctions, on Table 1 you can find the most common failures and the means of appropriate search: Table 1. Troubleshooting Failure Possible cause Troubleshooting The sensor doesn’t react to pressure Pressure channel occlusion 1 - Sensor power-off and disassembly •...
  • Page 12: Safe Application Parameterization

    The configuration tool calculates the CRCs of the current parameter set for SRDO1 and SRDO2 (SRDOx signature), writes it to the device and finally writes the Safety Configuration valid flag (0xA5) to confirm the end of the configuration. Here follows a reference to the parameters used to implement this procedure: Index Sub-index Parameter Name...
  • Page 13 NOTE: For further specification on CANopen Safety communication see also the Protocol User Manual. via Sebina, 74 - 25050 PROVAGLIO D’ISEO (BS) - ITALIA tel. 0309888.1 - fax. 0309839063 - Internet: http://www.gefran.com 80792A_Manual of Electrical Installation for Pressure Probes Complete_KMC_10-2024_ENG...