Pure ® Salt Chlorinator IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Scan this QR code for more information, or visit www.intermatic.com...
The Intermatic I-Pure Salt Chlorinator controller internally contains live components. There is a danger of electric shock if opened. If the power cord is damaged then it should be replaced by the manufacturer, their agent or similar.
Page 3
OFF before working on electrical connections. If you are not familiar with the pool filtering system and heater operations, DO NOT adjust or service the I-Pure Salt Chlorinator system without consulting a pool dealer or a qualified pool technician. Intermatic I-Pure Installation and User’s Guide ®...
Page 4
Use baking soda to neutralize the acid. If this occurs, carefully pour baking soda onto the acid until the fizzing stops, then mop or scoop up the residue. Large acid spills must be handled by the local fire department or hazardous materials experts. Intermatic ® I-Pure Installation and User’s Guide...
Before installing the chlorinator, review and understand all warnings, safety information in this guide. Failure to follow these instructions or improper installation of the chlorinator can result in damage to the pool finish or the vinyl liner. Intermatic disclaims any liability for repairs or replacement to any of these structures or components of the customer’s pool. See page 38 for Limited Warranty information.
Contents Important Safety Precautions and Warnings ....... 2-5 Intermatic I-Pure Salt Chlorinator Overview ........ 7 The Controller and Cell Power Switch ......... 8 Controller Status LEDs ..............9 Controller Operation ..............11 Chlor Boost (Super Chlorination) ..........11 Output LED indicators ............... 11 Temporary Change of Polarity ...........
Intermatic I-Pure Salt Chlorinator Overview ® The Intermatic ® I-Pure Salt Chlorinator system can be used standalone or connected to any automation system. The I-Pure features a platinum 1.0 mm coated titanium plate cell. The cell is made of a solid plate cathode and anode with end caps filled with resin to seal and protect the lead connectors.
ONLY WHEN THE FILTER PUMP IS ON. NEVER power on the Controller when the pool filter pump is OFF and water is not flowing through the cell. This prevents a gas build-up if the pool pump stops or pool valve is closed. See page 29. Intermatic ® I-Pure Installation and User’s Guide...
20% LEDs are solid Green. Continue this process to 100% (all LEDs solid Green). CAUTION LED is SOLID GREEN: NO FAULTS DETECTED. The chlorinator is operating normally. No Faults Detected LED Indicators Quick Reference Chart: A Quick Reference Chart is attached to the Controller cell cable. Intermatic I-Pure Installation and User’s Guide ®...
Page 10
1-2 hours due to excessive heat and a warning LED will be displayed. Once the internal temperature cools down, the chlorinator will come back ON again and produce chlorine at its previous output. Intermatic ® I-Pure Installation and User’s Guide...
75% of each hour of pump run time. 100% = 10% to 100% LEDs are solid GREEN - Produces chlorine 100% of each hour of The above indicates 50% output display pump run time. Intermatic I-Pure Installation and User’s Guide ®...
5. To change the reversing hours, press the “DECREASE (-)” or “INCREASE (+)” button to switch from one reversing hour to another. 6. Once you have selected the reversing time you require, turn the unit “OFF”. The new setting will apply next time you turn the unit “ON”. Intermatic ® I-Pure Installation and User’s Guide...
CAUTION: Metals Test: Periodic testing for metals such as copper, iron, and manganese is recommended. These metals can damage the chlorinator cell and other pool equipment and should not be present in the pool water. If those metals are present, contact your pool professional. Intermatic I-Pure Installation and User’s Guide ®...
Page 14
Without stabilizers, it may be necessary to run the chlorinator for longer hours. CAUTION: Only add chemicals using the method and quantities as instructed on the packaging provided. If in doubt about the chemical results achieved, then consult your local pool professional. Intermatic ® I-Pure Installation and User’s Guide...
EXTRA CARE MUST BE TAKEN WHEN INSTALLING, MAINTAINING AND OPERATING ACID PUMP FEED SYSTEMS. ACID IS DANGEROUS TO HANDLE AND SHOULD BE PROPERLY CONTAINED, TRANSPORTED, POURED, STORED, AND DISPENSED. Continue to next page for cell cleaning instructions. Intermatic I-Pure Installation and User’s Guide ®...
IMPORTANT: DO NOT return the mixture to the pool. Dispose of the used mixture in a safe manner. Inspecting the I-Pure Controller The controller power AC wires MUST plug into one of the high power AUX Relays located in the Intermatic Load Center or Power Center.
9. Lastly after all is correct and running the Warning Indicator LED should be SOLID GREEN. Note: Run the chlorinator for 6-10 hours per day in the summer and 3-6 hours per day in the winter. Intermatic I-Pure Installation and User’s Guide...
WARNING: RISK OF ELECTRIC SHOCK! Only qualified, licensed personnel should install the I-Pure Salt Chlorinator to the Intermatic Optimizer Load Center or Power Center enclosures. A trained professional familiar with pool/spa and equipment must perform all pool/spa equipment installation, including pumps, lights and other wiring connections.
Dummy Cell before installing the chlorinator cell in the pool hydraulics. After the pool system has flushed out the debris from the pipes, remove the Dummy Cell and install the chlorinator cell, as shown on page 27. Intermatic I-Pure Installation and User’s Guide...
Salt: 3000 - 3500 ppm (high salt warning comes on at 5250 ppm) Metals (Copper, Iron, Manganese): None Nitrates: None Phosphates: Less than 125 ppb Saturation Index: -0.3 to 0.3 (0.0 is best) Intermatic ® I-Pure Installation and User’s Guide...
flow switch and cell. Cell TO AN AUTOMATION SYSTEM FILTER PUMP RELAY OR ASSOCIATED AUX RELAY (OPTIMIZER). Flow Switch See Page 29 Filter Heater Pump Controller and Cell Plumbing Diagram Intermatic I-Pure Installation and User’s Guide ®...
(2) mounting bracket tabs. 1.75 in Seat the Controller onto the lower brackets (4.45 cm) to secure in place. Lower rear brackets CONTROLLER BONDING LUG. See page 30. Tools for mounting the controller Intermatic ® I-Pure Installation and User’s Guide...
(3) feet (91.4 cm) away from the heater outlet. For a pool/spa combination system, to avoid creating a gas trap in the pipes, install the cell BEFORE the pool/spa return valve to provide proper Intermatic I-Pure Installation and User’s Guide ®...
Page 28
Cell Connection Plugs: Cell Power in Cable (White to White) (Black to Black). To Associated AUX Relay, see page 29. To Flow Switch, Cell with Nut Couplings, Cell plugs and Controller cable see page 31. Intermatic ® I-Pure Installation and User’s Guide...
Wiring the Controller to an Automation System Relay WARNING: IF THE CHLORINATOR UNIT IS NOT CONNECTED CORRECTLY TO THE INTERMATIC OPTIMIZER SYSTEM, HAZARDOUS CHLORINE GAS CAN BUILDUP AND CAUSE PERSONAL INJURY. IMPORTANT: For third party automation systems, the controller power wires MUST BE connected to the LOAD SIDE of the filter pump relay.
BONDING and GFCI: Is for personnel protection and designed to keep the pool equipment voltages level. • Testing and bonding of the pool system should be done annually during a normal maintenance and service. CHLORINATOR CONTROLLER GROUND BONDING LUG Intermatic ® I-Pure Installation and User’s Guide...
3. Remove the flow switch assembly from the clear acrylic tee. 4. Ensure that the o-ring (2) is kept in a safe place. CONNECT TO CONTROLLER CONNECTOR CONNECT FLOW SWITCH PLUG INTO CONNECTOR Flow Switch Water Sensor with attached cable Intermatic I-Pure Installation and User’s Guide ®...
Load Center: Accessing the High Voltage Compartment To access the Intermatic Optimizer Load Center breaker base and power relays in the high voltage compartment: 1. Turn OFF the main AC power to the Load Center. 2. Unlatch the front door. Open the front door.
Power Center: Accessing the High Voltage Compartment To access the Intermatic Optimizer Power Center and power relays in the high voltage compartment: 1. Turn OFF the main AC power to the Power Center. 2. Unlatch the front door. Open the front door.
If all conditions are correct, then cell could be at the end of its life. Faulty control PCB or main Contact Intermatic Technical Support (see the last page of PCB in the controller. the manual). Warning LED is blinking Low or no water flow.
Page 35
If this does not work then not changing direction. it could indicate a faulty main controller PCB or PCB relay. Contact Intermatic Technical Support (see the last page of the manual). 3. Decrease the cell cleaning time (see page 16).
LED (20% & 50%) = Model 25K (Default Model Size) LED (40% & 100%) = Model 40K LED (60% & 100%) = Model 60K 3. Turn the unit OFF and back ON to save the model size. Intermatic I-Pure Installation and User’s Guide ®...
This warranty service is available by either (a) returning the product to the point of purchase or (b) by completing a warranty claim online at www.intermatic.com. You are required to provide a receipt, the model number and/or serial number when exercising this limited warranty.