INSTALLATION AND MAINTENANCE INSTRUCTIONS
A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST
IMPORTANCE THAT THIS VENT BE INSTALLED ONLY IN ACCORDANCE WITH THESE
INSTRUCTIONS.
WARNING: THIS IS A MAJOR RISK OF FIRE IF LOOSE FILL INSULATION COMES IN
CONTACT WITH THE CHIMNEY. IT IS PARTICULARLY IMPORTANT TO INSURE THAT
THERE IS NEVER ANY INSULATION ABOVE THE RADIATION SHIELD IN THE ATTIC.
This vent is intended for use with the following:
• Automatic particulate fuel-burning appliances that exhaust low temperature flue gases (572ºF / 300ºC
max.).
• Gas and liquid fuel-burning appliances that exhaust low temperature flue gases (572ºF / 300ºC max.)
and that are approved for use with type L venting systems.
• Gas fuel-burning appliances that exhaust low temperature flue gases (473ºF / 245ºC max.) and that are
approved for use with type B venting systems.
THE VENT SHOULD BE SIZED ACCORDING TO THE APPLIANCE MANUFACTURER'S
INSTRUCTIONS.
Use only ICC model EXCELPellet components. Failure to do so will void the certification and warranty of
the product.
Keep these installation and operating instructions in a safe location for future reference.
Contact local building or fire officials about restrictions and installation inspection in your area.
EXCELPellet has been tested and listed to the UL 641,
CAN/ULC-S609 and ULC/ORD-C441-1992 standards
by INTERTEK. Listing # 5965.
EXCELPellet
FACTORY BUILT PELLET CHIMNEY
ICC INDUSTRIAL CHIMNEY COMPANY INC.
400 J.F. Kennedy, St. Jerome
Quebec, Canada, J7Y 4B7
Tel.: (450) 565-6336
Fax: (450) 565-6519
www.icc-rsf.com
XLP-II_2008-05